KIT-ADC09JE5C-1

Heating capacity (A +7°C, W 35°C)

kW

9,00

COP (A +7°C, W 35°C)

4,48

Heating capacity (A +7°C, W 55°C)

kW

8,95

COP (A +7°C, W 55°C)

2,78

Heating capacity (A +2°C, W 35°C)

kW

7,00

COP (A +2°C, W 35°C)

3,40

Heating capacity (A +2°C, W 55°C)

kW

6,30

COP (A +2°C, W 55°C)

2,16

Heating capacity (A -7°C, W 35°C)

kW

6,12

COP (A -7°C, W 35°C)

2,78

Heating capacity (A -7°C, W 55°C)

kW

5,90

COP (A -7°C, W 55°C)

1,93

Cooling capacity (A 35°C, W 7°C)

kW

8,20

EER (A 35°C, W 7°C)

2,72

Cooling capacity (A 35°C, W 18°C)

kW

9,00

EER (A 35°C, W 18°C)

4,18

Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

193 / 130

Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

4,90 / 3,32

Heating average climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A+++ / A++

Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

227 / 160

Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

5,75 / 4,07

Heating warm climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A+++ / A+++

Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

164 / 116

Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

4,18 / 2,98

Heating cold climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A++ / A+

Indoor unit

WH-ADC0309J3E5C

Indoor sound pressure (Heat)

dB(A)

28

Indoor sound pressure (Cool)

dB(A)

28

Indoor dimension (Height)

mm

1650

Indoor dimension (Width)

mm

598

Indoor dimension (Depth)

mm

600

Indoor net weight

kg

Water pipe connector

Inch

R 1¼

A class pump (Number of speeds)

Variable Speed

A class pump (Input power Min)

W

30

A class pump (Input power Max)

W

120

Heating water flow (∆T=5 K. 35°C)

L/min

25,80

Capacity of integrated electric heater

kW

3,00

Indoor recommended fuse

A

25 / 16

Recommended cable size, supply 1

mm²

3 x 2,5

Recommended cable size, supply 2

mm²

3 x 1,5

Water volume

L

185

Maximum water temperature

°C

65

Material inside tank

Stainless steel

Tapping profile according EN16147

L

DHW tank ERP average climate efficiency rating (2)

A+ to F

A+

DHW tank ERP warm climate efficiency rating (2)

A+ to F

A+

DHW tank ERP cold climate efficiency rating (2)

A+ to F

A

DHW tank ERP average climate η

ηwh %

120

DHW tank ERP average climate SCOP

3,00

DHW tank ERP warm climate η

ηwh %

140

DHW tank ERP warm climate SCOP

3,50

DHW tank ERP cold climate η

ηwh %

99

DHW tank ERP cold climate SCOP

2,47

Outdoor unit

WH-UD09JE5-1

Outdoor sound power part load (Heat) (3)

dB(A)

59

Outdoor sound power full load (Heat)

dB(A)

69

Outdoor sound power full load (Cool)

dB(A)

69

Outdoor dimension (Height)

mm

795

Outdoor dimension (Width)

mm

875

Outdoor dimension (Depth)

mm

320

Outdoor net weight

kg

61

Refrigerant (R32) / CO2 Eq.

kg / T

1,27 / 0,857

Pipe diameter (Liquid)

Inch (mm)

1/4 (6,35)

Pipe diameter (Gas)

Inch (mm)

5/8 (15,88)

Pipe length range

m

3 ~ 50

Elevation difference (in/out)

m

30

Pipe length for additional gas

m

10

Additional gas amount

g/m

25

Operation range (Outdoor ambient)

°C

-20 ~ +35

Water outlet (Heat)

°C

20 ~ 60

Water outlet (Cool)

°C

5 ~ 20

 