DEYE SUN-40K-SG01HP3-EU-BM4 Inverter

SKU: F20GZD EAN: 5905951586076
Manufacturer

Rated power

Power supply

Hybrid device

MPPT

4

AFCI

Optional

Warranty

Net width

Net depth

Net height

CAN

Yes

RS485

Yes

SPD Type II

SPD Type I+II

Weight103 kg
CN85044086

5 061,93 
Gross

Login to place an order

Manual Deye SUN-40K-SG01HP3-EU-BM4 manual-deye-sun-40k-sg01hp3-eu-bm4.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

MPPT

4

AFCI

Optional

Warranty

Net width

Net depth

Net height

CAN

Yes

RS485

Yes

SPD Type II

SPD Type I+II

Weight103 kg
CN85044086

Three-Phase Hybrid Inverter Deye SUN-29.9/30/35/40/50 K-SG01HP3-EU-BM3/4

The Deye hybrid inverters from the SUN-29.9/30/35/40/50 K-SG01HP3-EU-BM3/4 series are advanced devices designed for large photovoltaic installations. Equipped with active phase imbalance balancing features, high voltage support, and the ability to integrate with diesel generators, they ensure reliable and efficient energy management in both on-grid and off-grid systems.

Key features of the Deye SUN-29.9/30/35/40/50 K-SG01HP3-EU-BM3/4 inverters:

  • Active Phase Imbalance Balancing – allows for handling up to 50% of the rated power on each phase, ensuring system stability.
  • Universal DC and AC sockets – adapted to European installation standards, facilitating the installation and integration process.
  • Support for Parallel Systems – enables the connection of up to 10 devices for increased installation scalability.
  • Maximum Charging and Discharging Current of 100A – high efficiency in energy storage processes.
  • High Voltage Batteries – provide better energy efficiency and increased reliability.
  • 6 Charging and Discharging Time Slots – flexible energy management tailored to individual user needs.
  • Support for Diesel Generators with AUTO-START Feature – allows for energy storage in emergency power systems.

Who is this a good choice for?

The three-phase hybrid inverters Deye SUN-29.9/30/35/40/50 K-SG01HP3-EU-BM3/4 are an ideal choice for large commercial, industrial, and residential installations that require flexible energy management. With advanced features and reliability, they perform excellently in systems with high energy demands.

Manual Deye SUN-40K-SG01HP3-EU-BM4 manual-deye-sun-40k-sg01hp3-eu-bm4.pdf

ModelSUN-29.9K-SG01HP3-EU-BM3SUN-30K-SG01HP3-EU-BM3SUN-35K-SG01HP3-EU-BM3SUN-40K-SG01HP3-EU-BM4SUN-50K-SG01HP3-EU-BM4
Battery Parameters
Battery TypeLithium-ionLithium-ionLithium-ionLithium-ionLithium-ion
Battery Voltage Range (V)160-800160-800160-800160-800160-800
Max. Charging Current (A)50+5050+5050+5050+5050+50
Max. Discharging Current (A)50+5050+5050+5050+5050+50
Number of Battery Ports22222
BMSSelf-adapting to BMSSelf-adapting to BMSSelf-adapting to BMSSelf-adapting to BMSSelf-adapting to BMS
DC Input (from PV)
Max. DC Input Power (W)3887039000455005200065000
Max. Input Voltage (V)10001000100010001000
Min. Input Voltage (V)180180180180180
MPPT Range (V)150-850150-850150-850150-850150-850
Full MPPT Power in Range (V)360-850360-850360-850360-850450-850
Rated MPPT Voltage (V)600600600600600
Max. Input Current (A)36+36+3636+36+3636+36+3636+36+36+3636+36+36+36
Max. Short Circuit Current (A)55+55+5555+55+5555+55+5555+55+55+5555+55+55+55
Number of MPPT33344
Number of Strings per MPPT22222
AC Output
Rated Power (W)2990030000350004000050000
Max. Output Power (W)2990033000385004400055000
Rated Output Current (A)45.4/43.445.5/43.553.1/50.860.7/5875.8/72.5
Rated Input Current (A)45.4/43.450/47.858.4/55.866.7/63.883.4/79.7
Max. Current Without Balancing in 3-phase Systems6060607080
Max. Surge/Transient Current200200200200200
Max. Surge Power (off grid)150% of rated power for 10 seconds150% of rated power for 10 seconds150% of rated power for 10 seconds150% of rated power for 10 seconds150% of rated power for 10 seconds
Generator Input/Smart Load /AC Current (A)45.4 / 200 / 45.445.5 / 200 / 45.553.1 / 200 / 53.160.7 / 200 / 60.775.8 / 200 / 75.8
Power Factorfrom -0.8 to 0.8 adjustablefrom -0.8 to 0.8 adjustablefrom -0.8 to 0.8 adjustablefrom -0.8 to 0.8 adjustablefrom -0.8 to 0.8 adjustable
Operating Frequency and Voltage50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type3-phase systems3-phase systems3-phase systems3-phase systems3-phase systems
(THD)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)
DC Input Current<0.5% input<0.5% input<0.5% input<0.5% input<0.5% input
Efficiency
Max. Efficiency97.60%97.60%97.60%97.60%97.60%
Measured Efficiency97.00%97.00%97.00%97.00%97.00%
MPPT Efficiency99.90%99.90%99.90%99.90%99.90%
Protection
IntegratedPV input protection against lightning strikes, islanding protection, protection against incorrect polarity on the PV input, Active insulation resistance measurement, Active RCD system monitoring leakage current, selective surge protectionPV input protection against lightning strikes, islanding protection, protection against incorrect polarity on the PV input, Active insulation resistance measurement, Active RCD system monitoring leakage current, selective surge protectionPV input protection against lightning strikes, islanding protection, protection against incorrect polarity on the PV input, Active insulation resistance measurement, Active RCD system monitoring leakage current, selective surge protectionPV input protection against lightning strikes, islanding protection, protection against incorrect polarity on the PV input, Active insulation resistance measurement, Active RCD system monitoring leakage current, selective surge protectionPV input protection against lightning strikes, islanding protection, protection against incorrect polarity on the PV input, Active insulation resistance measurement, Active RCD system monitoring leakage current, selective surge protection
Internal Surge ProtectionDC Type II / AC Type IIIDC Type II / AC Type IIIDC Type II / AC Type IIIDC Type II / AC Type IIIDC Type II / AC Type III
Certifications
Grid StandardsVDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150
EMC / StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Information
Operating Temperature (℃)-40~60℃, >45℃ derating-40~60℃, >45℃ derating-40~60℃, >45℃ derating-40~60℃, >45℃ derating-40~60℃, >45℃ derating
Coolingactive coolingactive coolingactive coolingactive coolingactive cooling
Operating Noise (dB)≤65 dB≤65 dB≤65 dB≤65 dB≤65 dB
Communication with BMSRS485; CANRS485; CANRS485; CANRS485; CANRS485; CAN
Weight (kg)7575757575
Dimensions (mm)527W×894H×294D527W×894H×294D527W×894H×294D527W×894H×294D527W×894H×294D
Protection (IP)IP65IP65IP65IP65IP65
Installation Methodwall-mountedwall-mountedwall-mountedwall-mountedwall-mounted
Warranty5 years5 years5 years5 years5 years

Official distribution