Inverter DEYE SUN-80K-SG02HP3-EU-EM6
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 6 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | Yes |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 126 kg |
| CN | 85044086 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 6 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | Yes |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 126 kg |
| CN | 85044086 |
Deye Three-Phase Hybrid Inverters SUN-60/75/80K-SG02HP3-EU-EM6
The Deye three-phase hybrid inverters from the SUN-K-SG02HP3-EU-EM6 series are high-power, technologically advanced devices designed for commercial and industrial applications. They offer power ratings from 60 kW to 80 kW, 100% unbalanced output on each phase, and the ability to operate in parallel up to 10 units, both on-grid and off-grid. With compatibility for high-voltage lithium-ion batteries, a maximum charging/discharging current of 160A, and support for energy storage from diesel generators, these inverters deliver top performance and flexibility.
Key features of the Deye SUN-K-SG02HP3-EU-EM6 Hybrid Inverters:
- High power and scalability: Rated models at 60 kW, 75 kW, and 80 kW, with the option to run up to 10 units in parallel, enabling very large-scale systems.
- 100% unbalanced output: Ensures optimal use of energy on each of the three phases, which is crucial for uneven loads in commercial installations.
- Compatibility with high-voltage batteries: Supports lithium-ion batteries with voltages from 160–1000V and a maximum charging/discharging current of 160A (80+80A across two battery inputs).
- Advanced energy management: Allows configuration of six charging/discharging periods for batteries and supports energy storage from diesel generators and AC coupling for retrofitting existing solar systems.
- High efficiency and reliability: Peak efficiency up to 97.60%, MPPT efficiency >99%, and numerous integrated protections, including DC reverse polarity protection and AC/DC surge protection (Type II).
- Intelligent cooling and extensive communications: Intelligent air cooling, IP65 protection rating, and a wide range of communication options (RS485/RS232/CAN, with optional GPRS/WIFI/Bluetooth/4G/LAN).
Who is this a good choice for?
These Deye hybrid inverters are an excellent choice for large commercial and industrial installations that require a reliable and highly efficient energy management system. Their high power, parallel operation capability, support for high-voltage batteries, and advanced energy management features (including generator integration) make them ideal for optimizing energy costs, ensuring power continuity, and maximizing the use of renewable energy in demanding applications.
| Parameter | SUN-60K-SG02HP3-EU-EM6 | SUN-75K-SG02HP3-EU-EM6 | SUN-80K-SG02HP3-EU-EM6 |
|---|---|---|---|
| Battery Input Data | |||
| Battery Type | Lithium-ion | Lithium-ion | Lithium-ion |
| Battery Voltage Range (V) | 160-1000 | 160-1000 | 160-1000 |
| Max. Charging Current (A) | 80+80 | 80+80 | 80+80 |
| Max. Discharging Current (A) | 80+80 | 80+80 | 80+80 |
| Charging Strategy for Li-ion Battery | Self-adapts to BMS | Self-adapts to BMS | Self-adapts to BMS |
| Number of Battery Inputs | 2 | 2 | 2 |
| PV String Input Data | |||
| Maximum Available PV Power (W) | 120000 | 150000 | 160000 |
| Maximum PV Input Power (W) | 96000 | 120000 | 128000 |
| Maximum PV Input Voltage (V) | 1000 | 1000 | 1000 |
| Starting Voltage (V) | 180 | 180 | 180 |
| MPPT Voltage Range (V) | 150-850 | 150-850 | 150-850 |
| Rated PV Input Voltage (V) | 650 | 650 | 650 |
| Max. Operating PV Input Current (A) | 36+36+36+36+36+36 | 36+36+36+36+36+36 | 36+36+36+36+36+36 |
| Maximum Input Short-Circuit Current (A) | 54+54+54+54+54+54 | 54+54+54+54+54+54 | 54+54+54+54+54+54 |
| Number of MPP Trackers/Strings per MPP Tracker | 6/2+2+2+2+2+2 | 6/2+2+2+2+2+2 | 6/2+2+2+2+2+2 |
| AC Input/Output Data | |||
| Rated AC Input/Output Active Power (W) | 60000 | 75000 | 80000 |
| Max. AC Input/Output Apparent Power (VA) | 66000 | 82500 | 88000 |
| Rated AC Input/Output Current (A) | 91/87 | 113.7/108.7 | 121.3/115.9 |
| Max. AC Input/Output Current (A) | 100/95.7 | 125/119.6 | 133.4/127.6 |
| Max. Continuous AC Transfer Current (grid to load) (A) | 200 | 200 | 200 |
| Peak Power (off-grid) (W) | 1.5 times rated power, 10s | 1.5 times rated power, 10s | 1.5 times rated power, 10s |
| Power Factor Regulation Range | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
| Rated Voltage/Input/Output Range (V) | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un |
| Rated Frequency/Input/Output Grid Range (Hz) | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 |
| Grid Connection Type | 3L+N+PE | 3L+N+PE | 3L+N+PE |
| Total Harmonic Current Distortion THDI | <3% (rated power) | <3% (rated power) | <3% (rated power) |
| DC Injected Current | <0.5% In | <0.5% In | <0.5% In |
| Efficiency | |||
| Max. Efficiency (%) | 97.60% | 97.60% | 97.60% |
| Euro Efficiency (%) | 97.0% | 97.0% | 97.0% |
| MPPT Efficiency (%) | >99% | >99% | >99% |
| Hardware Protection | |||
| Integrated | DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Protection against load drop during surge events, Ground fault current monitoring, Arc fault circuit interrupter (optional), Supply grid monitoring, Islanding protection monitoring, Ground fault detection, DC input switch, DC terminal insulation impedance monitoring, Residual current detection (RCD), Surge protection level | ||
| Surge Protection Level | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) |
| Interface | |||
| Communication Interface | RS485/RS232/CAN | RS485/RS232/CAN | RS485/RS232/CAN |
| Monitoring Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | GPRS/WIFI/Bluetooth/4G/LAN (optional) | GPRS/WIFI/Bluetooth/4G/LAN (optional) |
| General Data | |||
| Operating Temperature Range (°C) | -40 to +60°C, power derating above 45°C | -40 to +60°C, power derating above 45°C | -40 to +60°C, power derating above 45°C |
| Permissible Ambient Humidity (%) | 0-100% | 0-100% | 0-100% |
| Max. Altitude (m) | 3000m | 3000m | 3000m |
| Noise (dB) | ≤65 | ≤65 | ≤65 |
| Protection Rating (IP) | IP 65 | IP 65 | IP 65 |
| Inverter Topology | Non-isolated | Non-isolated | Non-isolated |
| Overvoltage Category | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) |
| Cabinet Size (W x H x D mm) | 606×927×314 (Without connectors and mounting brackets) | 606×927×314 (Without connectors and mounting brackets) | 606×927×314 (Without connectors and mounting brackets) |
| Weight (kg) | 97.5 | 97.5 | 97.5 |
| Cooling Type | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling |
| Warranty (Years) | 5 Years/10 Years (Warranty period depends on the inverter’s final installation location. For more information, please check the warranty policy) | 5 Years/10 Years (Warranty period depends on the inverter’s final installation location. For more information, please check the warranty policy) | 5 Years/10 Years (Warranty period depends on the inverter’s final installation location. For more information, please check the warranty policy) |
| Grid Regulations | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety/EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |