Inverter SOLAX X3-HYB-6.0-G4 Pro WiFi + LAN
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 39,06 kg |
| CN | 85044085 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 39,06 kg |
| CN | 85044085 |
Three-Phase Hybrid Inverter SolaX Power X3-HYB-G4 PRO
The three-phase hybrid inverter SolaX Power X3-HYB-G4 PRO is an advanced solution for residential properties, offering intelligent energy management and high performance. Available in a wide power range from 4 kW to 15 kW, it provides compatibility with V2H technology, intelligent scheduling, and integration with a wireless meter. With dual battery ports, a wide MPPT range and the ability to support 200% PV oversizing, it is a flexible and reliable device for maximizing self-consumption.
Key features of the SolaX Power X3-HYB-G4 PRO Hybrid Inverter:
- Intelligent energy management: Compatibility with V2H for smart home energy integration, Smart Schedule, Smart Scene, 24/7 TOU and integration with VPP (OpenADR, IEEE2030.5, FCAS, API).
- High efficiency and PV flexibility: 20A DC input per MPPT with 3 trackers, 200% PV oversizing capability, AC output up to 110% and a very wide MPPT range (110–950V).
- Proven reliability and safety: Up to 200% EPS output power for 10 seconds, UPS-level transfer time below 10 ms, optional rapid shutdown, Type II SPD protection on AC and DC sides and optional AFCI protection.
- Flexible expansion options: Dual battery ports and a “2-in-1” expansion function, extra ports to simplify wiring and a functional, stylish cable cover.
- Versatile operating modes: Supports microgrid and generator modes for a variety of applications.
- Efficiency curve: High efficiency maintained across a wide load range, as demonstrated by the efficiency curve for the 15 kW model.
Who is this a good choice for?
The SolaX Power X3-HYB-G4 PRO inverter is an excellent choice for single-family homeowners looking for an advanced, efficient and reliable hybrid system. Its intelligent energy management features, high flexibility in configuring the PV array and batteries, and extensive safety and adaptation options make it an ideal solution for maximizing self-consumption, providing backup power and integrating with a smart home. The wide power range allows the unit to be matched to individual energy needs.
| Parameter | X3-HYB-4.0-P | X3-HYB-5.0-P | X3-HYB-6.0-P | X3-HYB-8.0-P | X3-HYB-10.0-P | X3-HYB-12.0-P | X3-HYB-15.0-P |
|---|---|---|---|---|---|---|---|
| PV INPUT | |||||||
| Max. recommended PV array power (kWp) | 8 | 10 | 12 | 16 | 20 | 24 | 30 |
| Max. PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
| Rated PV input voltage (V) | 650 | 650 | 650 | 650 | 650 | 650 | 650 |
| Operating voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| MPPT voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| Start-up voltage (V) | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
| Number of MPP trackers / strings per tracker | 2 (1 / 1) | 2 (1 / 1) | 2 (1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) |
| Max. input current per MPPT (MPPT1/2/3) (A) | 20 / 20 | 20 / 20 | 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 |
| Max. short-circuit input current per MPPT (MPPT1/2/3) (A) | 25 / 25 | 25 / 25 | 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 |
| AC INPUT & OUTPUT (GRID) | |||||||
| Rated output power (W) | 4000 | 5000 (AS 4777 4999 W) | 6000 | 8000 | 10000 (AS 4777 9999 W) | 12000 | 15000 (AS 4777 14999 W) |
| Rated output current (A) | 5.8 | 7.2 | 8.7 | 11.6 | 14.5 | 17.5 | 21.8 |
| Max. output apparent power (VA) | 4400 | 5500 (AS 4777 4999 VA) | 6600 | 8800 | 11000 (AS 4777 9999 VA) | 13200 | 16500 (AS 4777 14999 VA) |
| Max. continuous output current (A) | 6.7 | 6.7 | 8.4 | 10.0 | 13.4 | 20.0 | 25.0 |
| Rated AC voltage | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V |
| Max. AC input apparent power (kVA) | 8.4 | 10.5 | 12.6 | 16.8 | 21.0 | 21.0 | 21.0 |
| Max. AC input current (A) | 12.2 | 15.2 | 18.2 | 24.3 | 30.4 | 30.4 | 30.4 |
| Rated AC frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
| AC frequency range (Hz) | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 |
| Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
| THDi (Rated Power) (%) | <3 | <3 | <3 | <3 | <3 | <3 | <3 |
| BATTERY | |||||||
| Battery type | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium |
| Battery voltage range (V) | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 |
| Max. charge/discharge current (A) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) |
| EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||||
| Rated EPS output voltage, frequency | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz |
| Rated EPS output power (kVA) | 4 | 5 | 6 | 8 | 10 | 12 | 15 |
| Peak EPS output power | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
| Transfer time (ms) | < 10 | < 10 | < 10 | < 10 | < 10 | < 10 | < 10 |
| EFFICIENCY | |||||||
| Max. efficiency (%) | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 |
| European efficiency (%) | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 |
| ENVIRONMENTAL LIMITS | |||||||
| Protection rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating ambient temperature range (°C) | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 |
| Max. operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 |
| Relative humidity | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) |
| Overvoltage category | AC mains: III, Battery: II, PV: II | AC mains: III, Battery: II, PV: II | AC mains: III, Battery: II, PV: II | AC mains: III, Battery: II, PV: II | AC mains: III, Battery: II, PV: II | AC mains: III, Battery: II, PV: II | AC mains: III, Battery: II, PV: II |
| GENERAL | |||||||
| Dimensions (W x H x D) (mm) | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 |
| Net weight (kg) | 38 | 38 | 38 | 38 | 38 | 38 | 38 |
| Cooling concept | Natural cooling | Natural cooling | Natural cooling | Smart cooling | Smart cooling | Smart cooling | Smart cooling |
| Communication interfaces | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) |
| Power consumption (night) (W) | < 40W in standby mode, < 5W in idle mode | < 40W in standby mode, < 5W in idle mode | < 40W in standby mode, < 5W in idle mode | < 40W in standby mode, < 5W in idle mode | < 40W in standby mode, < 5W in idle mode | < 40W in standby mode, < 5W in idle mode | < 40W in standby mode, < 5W in idle mode |
| Topology | Non-isolated (transformerless) | Non-isolated (transformerless) | Non-isolated (transformerless) | Non-isolated (transformerless) | Non-isolated (transformerless) | Non-isolated (transformerless) | Non-isolated (transformerless) |
| Certificates and approvals | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 |
| Auxiliary AC power (APS) | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in |
| PROTECTION | |||||||
| Protections | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection |
| Active anti-islanding method | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift |
| Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
Notes:
① The maximum input voltage is the upper limit of DC voltage. Any DC input voltage higher than this may damage the inverter.
② An input voltage outside the MPPT voltage range may trigger inverter protection.
③ The AC frequency range may vary according to country codes.
④ If each of the two battery ports is connected to a separate battery, the current is 25 A per port. If one port is connected to a single battery, it is 30 A. If both ports are connected to one battery using a 2-in-1 splitter cable (sold separately), the current is 50 A.
⑤ Values are derated at +45°C.