Inverter SOLAX X3-HYB-6.0-G4 Pro WiFi + LAN

SKU: F20S10 EAN: 2010000033210
Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

3

Warranty

Net width

Net depth

Net height

RS485

Yes

SPD Type II

AFCI

Optional

MPPT voltage range

Weight 39,06 kg
CN 85044085
Price 1 806,54 
Gross

1 806,54 
Gross

In stock:

5 pcs
Login to place an order

1 806,54 
Gross

In stock:

5 pcs
Login to place an order

Datasheet Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Datasheet.pdf Warranty Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Warranty.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

3

Warranty

Net width

Net depth

Net height

RS485

Yes

SPD Type II

AFCI

Optional

MPPT voltage range

Weight 39,06 kg
CN 85044085

Three-Phase Hybrid Inverter SolaX Power X3-HYB-G4 PRO

The three-phase hybrid inverter SolaX Power X3-HYB-G4 PRO is an advanced solution for residential properties, offering intelligent energy management and high performance. Available in a wide power range from 4 kW to 15 kW, it provides compatibility with V2H technology, intelligent scheduling, and integration with a wireless meter. With dual battery ports, a wide MPPT range and the ability to support 200% PV oversizing, it is a flexible and reliable device for maximizing self-consumption.

Key features of the SolaX Power X3-HYB-G4 PRO Hybrid Inverter:

  • Intelligent energy management: Compatibility with V2H for smart home energy integration, Smart Schedule, Smart Scene, 24/7 TOU and integration with VPP (OpenADR, IEEE2030.5, FCAS, API).
  • High efficiency and PV flexibility: 20A DC input per MPPT with 3 trackers, 200% PV oversizing capability, AC output up to 110% and a very wide MPPT range (110–950V).
  • Proven reliability and safety: Up to 200% EPS output power for 10 seconds, UPS-level transfer time below 10 ms, optional rapid shutdown, Type II SPD protection on AC and DC sides and optional AFCI protection.
  • Flexible expansion options: Dual battery ports and a “2-in-1” expansion function, extra ports to simplify wiring and a functional, stylish cable cover.
  • Versatile operating modes: Supports microgrid and generator modes for a variety of applications.
  • Efficiency curve: High efficiency maintained across a wide load range, as demonstrated by the efficiency curve for the 15 kW model.

Who is this a good choice for?

The SolaX Power X3-HYB-G4 PRO inverter is an excellent choice for single-family homeowners looking for an advanced, efficient and reliable hybrid system. Its intelligent energy management features, high flexibility in configuring the PV array and batteries, and extensive safety and adaptation options make it an ideal solution for maximizing self-consumption, providing backup power and integrating with a smart home. The wide power range allows the unit to be matched to individual energy needs.

Datasheet Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Datasheet.pdf Warranty Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Warranty.pdf

 

Parameter X3-HYB-4.0-P X3-HYB-5.0-P X3-HYB-6.0-P X3-HYB-8.0-P X3-HYB-10.0-P X3-HYB-12.0-P X3-HYB-15.0-P
PV INPUT
Max. recommended PV array power (kWp) 8 10 12 16 20 24 30
Max. PV input voltage (V) 1000 1000 1000 1000 1000 1000 1000
Rated PV input voltage (V) 650 650 650 650 650 650 650
Operating voltage range (V) 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950
MPPT voltage range (V) 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950
Start-up voltage (V) 120 120 120 120 120 120 120
Number of MPP trackers / strings per tracker 2 (1 / 1) 2 (1 / 1) 2 (1 / 1) 3 (1 / 1 / 1) 3 (1 / 1 / 1) 3 (1 / 1 / 1) 3 (1 / 1 / 1)
Max. input current per MPPT (MPPT1/2/3) (A) 20 / 20 20 / 20 20 / 20 20 / 20 / 20 20 / 20 / 20 20 / 20 / 20 20 / 20 / 20
Max. short-circuit input current per MPPT (MPPT1/2/3) (A) 25 / 25 25 / 25 25 / 25 25 / 25 / 25 25 / 25 / 25 25 / 25 / 25 25 / 25 / 25
AC INPUT & OUTPUT (GRID)
Rated output power (W) 4000 5000 (AS 4777 4999 W) 6000 8000 10000 (AS 4777 9999 W) 12000 15000 (AS 4777 14999 W)
Rated output current (A) 5.8 7.2 8.7 11.6 14.5 17.5 21.8
Max. output apparent power (VA) 4400 5500 (AS 4777 4999 VA) 6600 8800 11000 (AS 4777 9999 VA) 13200 16500 (AS 4777 14999 VA)
Max. continuous output current (A) 6.7 6.7 8.4 10.0 13.4 20.0 25.0
Rated AC voltage 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V
Max. AC input apparent power (kVA) 8.4 10.5 12.6 16.8 21.0 21.0 21.0
Max. AC input current (A) 12.2 15.2 18.2 24.3 30.4 30.4 30.4
Rated AC frequency (Hz) 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60
AC frequency range (Hz) 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (Rated Power) (%) <3 <3 <3 <3 <3 <3 <3
BATTERY
Battery type Lithium Lithium Lithium Lithium Lithium Lithium Lithium
Battery voltage range (V) 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800
Max. charge/discharge current (A) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2)
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output voltage, frequency 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz
Rated EPS output power (kVA) 4 5 6 8 10 12 15
Peak EPS output power 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Transfer time (ms) < 10 < 10 < 10 < 10 < 10 < 10 < 10
EFFICIENCY
Max. efficiency (%) 98.0 98.0 98.0 98.0 98.0 98.0 98.0
European efficiency (%) 97.7 97.7 97.7 97.7 97.7 97.7 97.7
ENVIRONMENTAL LIMITS
Protection rating IP66 IP66 IP66 IP66 IP66 IP66 IP66
Operating ambient temperature range (°C) -35 – 60 -35 – 60 -35 – 60 -35 – 60 -35 – 60 -35 – 60 -35 – 60
Max. operating altitude (m) 3000 3000 3000 3000 3000 3000 3000
Relative humidity 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing)
Overvoltage category AC mains: III, Battery: II, PV: II AC mains: III, Battery: II, PV: II AC mains: III, Battery: II, PV: II AC mains: III, Battery: II, PV: II AC mains: III, Battery: II, PV: II AC mains: III, Battery: II, PV: II AC mains: III, Battery: II, PV: II
GENERAL
Dimensions (W x H x D) (mm) 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210
Net weight (kg) 38 38 38 38 38 38 38
Cooling concept Natural cooling Natural cooling Natural cooling Smart cooling Smart cooling Smart cooling Smart cooling
Communication interfaces COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump)
Power consumption (night) (W) < 40W in standby mode, < 5W in idle mode < 40W in standby mode, < 5W in idle mode < 40W in standby mode, < 5W in idle mode < 40W in standby mode, < 5W in idle mode < 40W in standby mode, < 5W in idle mode < 40W in standby mode, < 5W in idle mode < 40W in standby mode, < 5W in idle mode
Topology Non-isolated (transformerless) Non-isolated (transformerless) Non-isolated (transformerless) Non-isolated (transformerless) Non-isolated (transformerless) Non-isolated (transformerless) Non-isolated (transformerless)
Certificates and approvals IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21
Auxiliary AC power (APS) Built-in Built-in Built-in Built-in Built-in Built-in Built-in
PROTECTION
Protections Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II
Arc fault circuit interrupter (AFCI) Optional Optional Optional Optional Optional Optional Optional

Notes:

① The maximum input voltage is the upper limit of DC voltage. Any DC input voltage higher than this may damage the inverter.

② An input voltage outside the MPPT voltage range may trigger inverter protection.

③ The AC frequency range may vary according to country codes.

④ If each of the two battery ports is connected to a separate battery, the current is 25 A per port. If one port is connected to a single battery, it is 30 A. If both ports are connected to one battery using a 2-in-1 splitter cable (sold separately), the current is 50 A.

⑤ Values are derated at +45°C.