Module MEYER BURGER MB_B120AyB_385W

SKU: F10G0 EAN: 2010000033197
Manufacturer

Fullblack

Yes

Frame color

Efficiency

Product warranty

Linear power warranty

Module type

PV cell type

N-type HJT

Number of BusBar

Frame thickness

Height

Width

Maximum static load (Pa)

Cable length (+)

1200 mm

Cable length (-)

1200 mm

Quantity per pallet

Weight 19,7 kg
CN 85414300
Price 80,86 
Gross

80,86 
Gross

In stock:

17 pcs
Login to place an order

80,86 
Gross

In stock:

17 pcs
Login to place an order

Datasheet Meyer Burger MB_B120AyB_375-395W Meyer-Burger-MB_B120AyB_375-395W-Datasheet.pdf

Product details

Manufacturer

Fullblack

Yes

Frame color

Efficiency

Product warranty

Linear power warranty

Module type

PV cell type

N-type HJT

Number of BusBar

Frame thickness

Height

Width

Maximum static load (Pa)

Cable length (+)

1200 mm

Cable length (-)

1200 mm

Quantity per pallet

Weight 19,7 kg
CN 85414300

Meyer Burger Black MB_B120AYB_XXX

The high-performance Heterojunction solar module with SmartWire Connection Technology (SWCT®) delivers maximum energy yield and an attractive appearance, even on cloudy or very hot days. Made in Germany and engineered in Switzerland, the product ensures top quality, long service life thanks to cell stability and crack resistance, and sustainable production using 100% renewable energy without lead.

Key features of the Meyer Burger Black MB_B120AYB_XXX:

  • Heterojunction (HJT) technology with SWCT® for higher energy output.
  • Manufactured in Germany and engineered in Switzerland, guaranteeing the highest quality standards.
  • Power output range of 375-395 Wp per module.
  • Long lifespan and reliability backed by a 25-year product and performance warranty.
  • Sleek design with a black aluminum frame that complements demanding architecture.
  • High resistance to environmental stress, certified to standards including IEC 61730.

Who is this a good choice for?

The Meyer Burger Black modules are an ideal choice for owners of residential rooftop systems looking for attractive, high-performance photovoltaic solutions. They perform well in projects that demand high energy efficiency, even under challenging lighting and temperature conditions. The long-term warranty and sustainable manufacturing emphasize their value as a long-term investment, minimizing operating costs and environmental impact.

Datasheet Meyer Burger MB_B120AyB_375-395W Meyer-Burger-MB_B120AyB_375-395W-Datasheet.pdf

Parameter MB_B120AYB_375 Wp MB_B120AYB_380 Wp MB_B120AYB_385 Wp MB_B120AYB_390 Wp MB_B120AYB_395 Wp
Mechanical specifications
Dimensions (mm) 1767 x 1041 x 35 1767 x 1041 x 35 1767 x 1041 x 35 1767 x 1041 x 35 1767 x 1041 x 35
Weight (kg) 19.7 19.7 19.7 19.7 19.7
Front cover Tempered solar glass, 3.2 mm, with anti-reflective coating Tempered solar glass, 3.2 mm, with anti-reflective coating Tempered solar glass, 3.2 mm, with anti-reflective coating Tempered solar glass, 3.2 mm, with anti-reflective coating Tempered solar glass, 3.2 mm, with anti-reflective coating
Rear cover Black back sheet with moisture barrier Black back sheet with moisture barrier Black back sheet with moisture barrier Black back sheet with moisture barrier Black back sheet with moisture barrier
Frame Black anodized aluminium Black anodized aluminium Black anodized aluminium Black anodized aluminium Black anodized aluminium
Solar cell type 120 half-cells, mono n-Si, HJT with SWCT® 120 half-cells, mono n-Si, HJT with SWCT® 120 half-cells, mono n-Si, HJT with SWCT® 120 half-cells, mono n-Si, HJT with SWCT® 120 half-cells, mono n-Si, HJT with SWCT®
Junction boxes 3 diodes, IP68 per IEC 62790 3 diodes, IP68 per IEC 62790 3 diodes, IP68 per IEC 62790 3 diodes, IP68 per IEC 62790 3 diodes, IP68 per IEC 62790
Cables 8 x 3.5 mm², length 1.2 m, compliant with EN 50618 8 x 3.5 mm², length 1.2 m, compliant with EN 50618 8 x 3.5 mm², length 1.2 m, compliant with EN 50618 8 x 3.5 mm², length 1.2 m, compliant with EN 50618 8 x 3.5 mm², length 1.2 m, compliant with EN 50618
Connectors 1: MC4; 2: MC4-Evo2; 3: UKT Energy PV-CO02; 4: TE Connectivity PV4-S1 per IEC 62852, IP68 when connected 1: MC4; 2: MC4-Evo2; 3: UKT Energy PV-CO02; 4: TE Connectivity PV4-S1 per IEC 62852, IP68 when connected 1: MC4; 2: MC4-Evo2; 3: UKT Energy PV-CO02; 4: TE Connectivity PV4-S1 per IEC 62852, IP68 when connected 1: MC4; 2: MC4-Evo2; 3: UKT Energy PV-CO02; 4: TE Connectivity PV4-S1 per IEC 62852, IP68 when connected 1: MC4; 2: MC4-Evo2; 3: UKT Energy PV-CO02; 4: TE Connectivity PV4-S1 per IEC 62852, IP68 when connected
Drainage holes 4.5 mm (8x) 4.5 mm (8x) 4.5 mm (8x) 4.5 mm (8x) 4.5 mm (8x)
Grounding holes 9 mm (4x) 9 mm (4x) 9 mm (4x) 9 mm (4x) 9 mm (4x)
Mounting holes 115 mm (distance between mounting and grounding holes), 320 mm (distance between mounting holes) 115 mm (distance between mounting and grounding holes), 320 mm (distance between mounting holes) 115 mm (distance between mounting and grounding holes), 320 mm (distance between mounting holes) 115 mm (distance between mounting and grounding holes), 320 mm (distance between mounting holes) 115 mm (distance between mounting and grounding holes), 320 mm (distance between mounting holes)
Electrical data¹
Power class 375 Wp 380 Wp 385 Wp 390 Wp 395 Wp
Efficiency (STC) (%) 20.4 20.7 20.9 21.2 21.5
Maximum power (STC) (Wp) 375 380 385 390 395
Short-circuit current (STC) (A) 8.5 8.5 8.5 8.5 8.5
Open-circuit voltage (STC) (V) 42.2 42.2 42.3 42.4 42.4
Rated current (STC) (A) 10.6 10.6 10.6 10.6 10.6
Voltage at maximum power (STC) (V) 35.7 36.1 36.4 36.7 37.0
Maximum power (NMOT) (Wp) 283 287 291 294 298
Short-circuit current (NMOT) (A) 7.9 8.0 8.0 8.0 8.1
Open-circuit voltage (NMOT) (V) 44.4 44.5 44.6 44.6 44.7
Rated current (NMOT) (A) 9.9 10.0 10.0 10.1 10.1
Voltage at maximum power (NMOT) (V) 37.8 38.2 38.5 38.9 39.2
Temperature coefficients
Temperature coefficient Isc (a) (%/K) +0.033 +0.033 +0.033 +0.033 +0.033
Temperature coefficient Voc (B) (%/K) -0.234 -0.234 -0.234 -0.234 -0.234
Temperature coefficient PMPP (Y) (%/K) -0.259 -0.259 -0.259 -0.259 -0.259
Nominal module operating temperature (NMOT) (°C) 44±2 44±2 44±2 44±2 44±2
Meyer Burger warranty
Product and power warranty 25 Years 25 Years 25 Years 25 Years 25 Years
First-year degradation 2.0% 2.0% 2.0% 2.0% 2.0%
Annual degradation 0.25% 0.25% 0.25% 0.25% 0.25%
System design characteristics
Max system voltage (V) 1000 1000 1000 1000 1000
Reverse current carrying capacity (OCPR) (A) 20 20 20 20 20
Max test load +/- (Pa) 6000/4000 6000/4000 6000/4000 6000/4000 6000/4000
Max design load +/- (Pa) 4000/2666 4000/2666 4000/2666 4000/2666 4000/2666
Protection class II II II II II
Reaction to fire classification (EN 13501-1 / EN 13501-5) E/BROOF (+1) E/BROOF (+1) E/BROOF (+1) E/BROOF (+1) E/BROOF (+1)
Operating temperature (°C) -40 to +85 -40 to +85 -40 to +85 -40 to +85 -40 to +85
Certifications
Certifications IEC 61215:2016, IEC 61730:2016, PID (IEC 62804), Salt mist resistance (IEC 61701) IEC 61215:2016, IEC 61730:2016, PID (IEC 62804), Salt mist resistance (IEC 61701) IEC 61215:2016, IEC 61730:2016, PID (IEC 62804), Salt mist resistance (IEC 61701) IEC 61215:2016, IEC 61730:2016, PID (IEC 62804), Salt mist resistance (IEC 61701) IEC 61215:2016, IEC 61730:2016, PID (IEC 62804), Salt mist resistance (IEC 61701)
Certifications pending Ammonia resistance (IEC 62716), dust and sand (IEC 60068) Ammonia resistance (IEC 62716), dust and sand (IEC 60068) Ammonia resistance (IEC 62716), dust and sand (IEC 60068) Ammonia resistance (IEC 62716), dust and sand (IEC 60068) Ammonia resistance (IEC 62716), dust and sand (IEC 60068)

Power tolerance -0 W/+5 W for STC. All data and specifications are provisional and may be changed at any time.

Official distribution

Other brands in our portfolio