FoxESS P3-12.0-SH Hybrid Inverter
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | Yes |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 38,4 kg |
| CN | 85044086 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | Yes |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 38,4 kg |
| CN | 85044086 |
FOX P3-S Three-Phase Hybrid Inverter
The Fox ESS P3-S series hybrid inverters are technologically advanced devices designed for efficient management of solar energy. They allow you to use power during the day and store it for nighttime, working with Fox ESS high-voltage batteries. They offer easy installation, resistance to outdoor conditions (IP65), and remote monitoring capabilities.
Key features of the FOX P3-S:
- Flexible power range from 5 kW to 15 kW, adaptable to installation needs.
- Compatible with high-voltage Lithium-Ion (LFP) batteries in the 100–800 V range.
- Three independent Maximum Power Point Tracking (MPPT) inputs for optimal PV panel performance.
- High MPPT efficiency up to 97.90% and maximum efficiency up to 99.90%.
- IP65 protection rating, enabling installation in various environments, including outdoors.
- Advanced system monitoring via a mobile app or web portal (FoxCloud V2.0).
Who is this a good choice for?
The Fox ESS P3-S inverters are an ideal solution for residential and commercial users seeking an efficient and flexible renewable energy management system. Their plug-and-play design, robust durability, and battery integration capabilities make them an excellent choice for photovoltaic installations aimed at maximizing solar self-consumption and ensuring reliable power supply.
| Parameter | P3-5.0-SH | P3-6.0-SH | P3-8.0-SH | P3-9.9-SH | P3-10.0-SH | P3-12.0-SH | P3-15.0-SH |
|---|---|---|---|---|---|---|---|
| PV INPUT | |||||||
| Max. PV Power [W] | 11000 | 11000 | 14000 | 13200 | 18000 | 20000 | 20000 |
| Max. Input Power [W] | 17600 | 18000 | 18000 | 24000 | 22500 | 30000 | 22500 |
| Max. Input Voltage [V] | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] |
| Nominal Input Voltage [V] | 620 | 620 | 620 | 620 | 620 | 620 | 620 |
| Max. MPPT Input Current [A] | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 |
| Max. MPPT Short-circuit Current [A] | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 |
| Max. MPPT Input Power [W] | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 |
| Min. PV Operating Voltage [V] | 90 [2] | 90 [2] | 90 [2] | 90 [2] | 90 [2] | 90 [2] | 90 [2] |
| MPPT Operating Voltage Range [V] | 120 ~ 950 | 120 ~ 950 | 120 ~ 950 | 120 ~ 950 | 120 ~ 950 | 120 ~ 950 | 120 ~ 950 |
| Start-up Voltage [V] | 140 | 140 | 140 | 140 | 140 | 140 | 140 |
| Number of Independent MPPTs | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Strings per MPPT | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 |
| BATTERIES | |||||||
| Battery Type | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) |
| Battery Voltage Range [V] | 100~800 | 100~800 | 100~800 | 100~800 | 100~800 | 100~800 | 100~800 |
| Min. Battery Operating Voltage [V] | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
| Min. Battery Voltage at Full AC Load [V] | 108 | 125 | 160 | 210 | 210 | 250 | 310 |
| Max. Charge/Discharge Current [A] | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Communication Interface | CAN | CAN | CAN | CAN | CAN | CAN | CAN |
| AC OUTPUT | |||||||
| Rated Output Power [W] | 5000 | 6000 | 8000 | 9900 | 10000 | 12000 | 15000 |
| Max. Apparent Power [VA] | 5500 | 6600 | 8800 | 9900 | 11000 [3] | 13200 | 16500 |
| Rated Grid Voltage (AC voltage range) [V] | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE |
| Rated Grid Frequency [Hz] | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 |
| Rated AC Current [A] (per phase) | 7,6 | 9,1 | 12,1 | 15,0 | 15,2 | 18,2 | 22,7 |
| Max. AC Current [A] (per phase) | 8,3 | 10,0 | 13,3 | 15,0 | 16,7 | 20,0 | 25,0 |
| Power Factor | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) |
| THDI [%] | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power |
| AC INPUT | |||||||
| Max. AC Input Power [VA] | 6000 | 7200 | 9600 | 12000 | 12000 | 14400 | 16000 |
| Rated AC Grid Voltage [V] | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE |
| Rated AC Grid Frequency [Hz] | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 |
| Max. AC Current [A] (per phase) | 9,1 | 10,9 | 14,5 | 18,2 | 18,2 | 21,8 | 24,2 |
| EPS OUTPUT | |||||||
| Max. Apparent Power [VA] | 5000 | 6000 | 8000 | 10000 | 10000 | 12000 | 15000 |
| Peak Apparent Power [VA] (60s) | 6000 | 7200 | 9600 | 12000 | 12000 | 14400 | 15000 |
| Rated EPS Voltage [V] | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE |
| Rated EPS Frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| Max. EPS Current [A] (per phase) | 7,2 | 8,7 | 11,6 | 14,5 | 14,5 | 17,4 | 21,7 |
| Power Factor | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) |
| Transfer Time [ms] | <20 | <20 | <20 | <20 | <20 | <20 | <20 |
| THDV [%] | <3 @ linear load | <3 @ linear load | <3 @ linear load | <3 @ linear load | <3 @ linear load | <3 @ linear load | <3 @ linear load |
| EFFICIENCY | |||||||
| MPPT Efficiency [%] | 97,30 | 97,70 | 97,70 | 97,90 | 97,90 | 97,90 | 97,90 |
| Max. Efficiency [%] | 99,90 | 99,90 | 99,90 | 99,90 | 99,90 | 99,90 | 99,90 |
| European Efficiency [%] | 97,20 | 97,20 | 97,20 | 97,20 | 97,20 | 97,20 | 97,20 |
| PROTECTIONS | |||||||
| PV Reverse Polarity Protection | YES | YES | YES | YES | YES | YES | YES |
| Battery Reverse Polarity Protection | YES | YES | YES | YES | YES | YES | YES |
| Anti-islanding Protection | YES | YES | YES | YES | YES | YES | YES |
| Short-circuit Protection | YES | YES | YES | YES | YES | YES | YES |
| Leakage Current Monitoring | YES | YES | YES | YES | YES | YES | YES |
| Insulation Resistance Monitoring | YES | YES | YES | YES | YES | YES | YES |
| Surge Category | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) |
| Reverse Polarity Protection | YES | YES | YES | YES | YES | YES | YES |
| Overcurrent / Overtemperature Protection | YES | YES | YES | YES | YES | YES | YES |
| AC/DC Surge Protection | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) |
| AFCI Protection | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
| DC Isolator | YES | YES | YES | YES | YES | YES | YES |
| GENERAL DATA | |||||||
| Dimensions (W*H*D) [mm] | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 |
| Package Dimensions (W*H*D) [mm] | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 |
| Net Weight [kg] | 34 | 34 | 34 | 34 | 34 | 34 | 34 |
| Gross Weight [kg] | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| Installation | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted |
| Operating Temperature Range [°C] | -25 ~ +60 (Derating above 45) | -25 ~ +60 (Derating above 45) | -25 ~ +60 (Derating above 45) | -25 ~ +60 (Derating above 45) | -25 ~ +60 (Derating above 45) | -25 ~ +60 (Derating above 45) | -25 ~ +60 (Derating above 45) |
| Storage Temperature [°C] | -40~+70 | -40~+70 | -40~+70 | -40~+70 | -40~+70 | -40~+70 | -40~+70 |
| Relative Humidity (storage/operation) [%] | 0~100 | 0~100 | 0~100 | 0~100 | 0~100 | 0~100 | 0~100 |
| Altitude [m] | <4000 @Derating above 2000 | <4000 @Derating above 2000 | <4000 @Derating above 2000 | <4000 @Derating above 2000 | <4000 @Derating above 2000 | <4000 @Derating above 2000 | <4000 @Derating above 2000 |
| Protection Class | I | I | I | I | I | I | I |
| Protection Rating | IP65 (Suitable for outdoor use) | IP65 (Suitable for outdoor use) | IP65 (Suitable for outdoor use) | IP65 (Suitable for outdoor use) | IP65 (Suitable for outdoor use) | IP65 (Suitable for outdoor use) | IP65 (Suitable for outdoor use) |
| Power Consumption [W] | 20 ~ 25 | 20 ~ 25 | 20 ~ 25 | 20 ~ 25 | 20 ~ 25 | 20 ~ 25 | 20 ~ 25 |
| Idle Mode | YES | YES | YES | YES | YES | YES | YES |
| Cooling | Natural | Natural | Natural | Natural | Natural | Fan cooling | Fan cooling |
| Noise Level [dB] | <40 | <40 | <40 | <40 | <40 | <55 | <55 |
| Inverter Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
| Communication | Ethernet, EMS(RS485), meter, WiLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WiLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WiLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WiLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WiLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WiLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WiLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready |
| Standard Warranty [Years] | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons |
| Audible Alarm | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) |
[1] For a 1000 V system, the maximum PV operating voltage is 950 V. [2] The inverter start-up supply voltage is 90 V. [3] Belgian safety regulations require the apparent power of 10000 W to be 10000 VA.