Inverter – HUAWEI – SUN 2000-10K-MAP0 – hybrid – HV

SKU: F220K2 EAN: 2010000035108
Weight 24,8 kg
CN 85044086
Price 1 873,33 
Gross

1 873,33 
Gross

In stock:

1 pcs
Login to place an order

1 873,33 
Gross

In stock:

1 pcs
Login to place an order

Datasheet Huawei 5K-MAP0-12K-MAP0 Huawei-5K-MAP0-12K-MAP0-Datasheet.pdf Warranty Huawei 5K-MAP0-12K-MAP0 Huawei-5K-MAP0-12K-MAP0-Warranty.pdf

Product details

Weight 24,8 kg
CN 85044086

HUAWEI SUN2000-5/6/8/10/12K-MAPO

The HUAWEI SUN2000-5/6/8/10/12K-MAPO hybrid inverter is an advanced solution for solar energy management and storage, offering high performance, flexibility, and safety. It provides a triple asymmetric output and supports LUNA2000 batteries, making it an ideal choice for modern photovoltaic installations.

Key features of the HUAWEI SUN2000-5/6/8/10/12K-MAPO:

  • Maximum PV power from 9,000 Wp to 22,000 Wp, depending on the model.
  • Support for LUNA2000 (S0/S1) energy storage with an operating voltage range of 600–980 V.
  • Can overload to 110% of rated power in on-grid mode and up to 200% in off-grid mode.
  • Supports triple asymmetric output, providing flexibility in power distribution.
  • Advanced safety features, including AFCI (arc-fault circuit interruption), connector temperature detection, and Type II surge protection.
  • Low night-time power consumption (below 5.5 W) and quiet operation thanks to natural convection (below 29 dB).

Who is this a good choice for?

The HUAWEI SUN2000-5/6/8/10/12K-MAPO inverters are designed for residential and commercial users seeking an efficient and reliable energy management system. With support for energy storage and whole-home backup power (with SmartGuard), they are ideal for installations where maximizing solar energy use and ensuring continuous power during grid outages are essential.

Datasheet Huawei 5K-MAP0-12K-MAP0 Huawei-5K-MAP0-12K-MAP0-Datasheet.pdf Warranty Huawei 5K-MAP0-12K-MAP0 Huawei-5K-MAP0-12K-MAP0-Warranty.pdf

Parameter SUN2000-5K-MAPO SUN2000-6K-MAPO SUN2000-8K-MAPO SUN2000-10K-MAPO SUN2000-12K-MAPO
Input (PV)
Max recommended PV power (Wp) 9,000 Wp 11,000 Wp 14,600 Wp 18,000 Wp 22,000 Wp
Max input voltage (V) 1,100 V 1,100 V 1,100 V 1,100 V 1,100 V
Operating voltage range (V) 160 – 1,000 V 160 – 1,000 V 160 – 1,000 V 160 – 1,000 V 160 – 1,000 V
Start-up voltage (V) 160 V 160 V 160 V 160 V 160 V
Rated input voltage (V) 600 V 600 V 600 V 600 V 600 V
Max input current per MPPT (A) 16 A 16 A 16 A 16 A 16 A
Max short-circuit current (A) 22 A 22 A 22 A 22 A 22 A
Number of MPPT trackers 2 2 2 2 2
Max inputs per MPPT 1 1 1 1 1
Input (DC Battery)
Compatible battery LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1
Operating voltage range (V) 600 – 980 V 600 – 980 V 600 – 980 V 600 – 980 V 600 – 980 V
Max operating current (A) 20 A 20 A 20 A 20 A 20 A
Max charging power (W) 12,000 W 12,000 W 12,000 W 12,000 W 12,000 W
Max discharging power (W) 5,500 W 6,600 W 8,800 W 11,000 W 12,000 W
Output (On Grid)
Grid connection Three-phase Three-phase Three-phase Three-phase Three-phase
Rated output power (W) 5,000 W 6,000 W 8,000 W 10,000 W 12,000 W
Max apparent power (VA) 5,500 VA 6,600 VA 8,800 VA 11,000 VA 13,200 VA
Rated output voltage (V) 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE
Overload capability 110% 110% 110% 110% 110%
Rated AC grid frequency (Hz) 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz
Max output current (A) 8.3 A 10.0 A 13.3 A 16.7 A 20.2 A
Adjustable power factor 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging
Max total harmonic distortion (%) ≤ 3% ≤ 3% ≤ 3% ≤ 3% ≤ 3%
Compatible backup device SmartGuard-63A-TO (3-phase) SmartGuard-63A-TO (3-phase) SmartGuard-63A-TO (3-phase) SmartGuard-63A-TO (3-phase) SmartGuard-63A-TO (3-phase)
Output (Off Grid)
Rated output power (W) 5,000 W 6,000 W 8,000 W 10,000 W 12,000 W
Rated output voltage (V) 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE
Overload 110% Continuous Continuous Continuous Continuous Continuous
Overload 150% 5 min (3-phase) / 5 min (single-phase) 5 min (3-phase) / 5 min (single-phase) 5 min (3-phase) / 5 min (single-phase) 1 min (3-phase) / 5 min (single-phase) 1 min (3-phase) / 5 min (single-phase)
Overload 200% 10 s 10 s 10 s 10 s 10 s
Automatic transfer time (ms) 20 ms (with SmartGuard-63A-TO) 20 ms (with SmartGuard-63A-TO) 20 ms (with SmartGuard-63A-TO) 20 ms (with SmartGuard-63A-TO) 20 ms (with SmartGuard-63A-TO)
Unbalanced load Yes, supports 100% three-phase unbalanced loads Yes, supports 100% three-phase unbalanced loads Yes, supports 100% three-phase unbalanced loads Yes, supports 100% three-phase unbalanced loads Yes, supports 100% three-phase unbalanced loads
Protection features
DC-side disconnect device Yes Yes Yes Yes Yes
Anti-islanding protection Yes Yes Yes Yes Yes
DC reverse polarity protection Yes Yes Yes Yes Yes
Insulation detection Yes Yes Yes Yes Yes
DC surge protection Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11
AC surge protection Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11 Yes, compatible with TYPE II protection according to EN/IEC 61643-11
Residual current detection Yes Yes Yes Yes Yes
AC overcurrent protection Yes Yes Yes Yes Yes
AC short-circuit protection Yes Yes Yes Yes Yes
AC overvoltage protection Yes Yes Yes Yes Yes
Arc fault protection Yes Yes Yes Yes Yes
Junction temperature detection Yes (PV and battery junctions) Yes (PV and battery junctions) Yes (PV and battery junctions) Yes (PV and battery junctions) Yes (PV and battery junctions)
Load control Yes Yes Yes Yes Yes
Battery charging from grid Yes Yes Yes Yes Yes
General specification
Max efficiency (%) 98.4% 98.6% 98.6% 98.6% 98.6%
European weighted efficiency (%) 97.5% 97.7% 98.0% 98.1% 98.2%
Operating temperature range (°C) -25°C – +60°C (-13°F +140°F) -25°C – +60°C (-13°F +140°F) -25°C – +60°C (-13°F +140°F) -25°C – +60°C (-13°F +140°F) -25°C – +60°C (-13°F +140°F)
Operating relative humidity (%) 0% – 100% RH 0% – 100% RH 0% – 100% RH 0% – 100% RH 0% – 100% RH
Max altitude (m) 4,000 m 4,000 m 4,000 m 4,000 m 4,000 m
Cooling Natural convection Natural convection Natural convection Natural convection Natural convection
Noise level (dB) ≤ 29 dB ≤ 29 dB ≤ 29 dB ≤ 29 dB ≤ 29 dB
Display LED indicators; Integrated WLAN + FusionSolar app LED indicators; Integrated WLAN + FusionSolar app LED indicators; Integrated WLAN + FusionSolar app LED indicators; Integrated WLAN + FusionSolar app LED indicators; Integrated WLAN + FusionSolar app
Communication RS485; WLAN / Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) RS485; WLAN / Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) RS485; WLAN / Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) RS485; WLAN / Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) RS485; WLAN / Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional)
Weight (with mounting brackets) (kg) 21 kg 21 kg 21 kg 21 kg 21 kg
Dimensions (with mounting brackets) (mm) 490 mm x 460 mm x 130 mm 490 mm x 460 mm x 130 mm 490 mm x 460 mm x 130 mm 490 mm x 460 mm x 130 mm 490 mm x 460 mm x 130 mm
IP rating IP66 IP66 IP66 IP66 IP66
Night power (W) < 5.5 W < 5.5 W < 5.5 W < 5.5 W < 5.5 W
Optimizer compatibility
Optimized compatibility SUN2000-450W-P2, SUN2000-600W-P SUN2000-450W-P2, SUN2000-600W-P SUN2000-450W-P2, SUN2000-600W-P SUN2000-450W-P2, SUN2000-600W-P SUN2000-450W-P2, SUN2000-600W-P
Grid connection standards
Standards EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11

*1 Max input voltage is the upper limit of DC voltage. Higher DC voltage may damage the inverter. *2 DC input voltage outside the operating range may cause the inverter to operate incorrectly.

Official distribution

Other brands in our portfolio