Inverter – ECOFLOW – EF HD-P3-6K0-S1 – hybrid – HV

SKU: F20W1 EAN: 2010000036068
Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net depth

CAN

RS485

SPD Type II

SPD Typ III

MPPT voltage range

Maksymalny prąd wejściowy na MPPT [A]

Maksymalna moc wejściowa [W]

Sprawność europejska

Weight 36,08 kg
CN 85044086
Price 0,30 
Gross

0,30 
Gross

0,30 
Gross

Datasheet EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Datasheet.pdf Manual EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Manual.pdf Declaration of confirmity EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Declaration-of-confirmity.pdf Comatibility letter EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Comatibility-letter.pdf Installation guide EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Installation-guide.pdf

Product details

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net depth

CAN

RS485

SPD Type II

SPD Typ III

MPPT voltage range

Maksymalny prąd wejściowy na MPPT [A]

Maksymalna moc wejściowa [W]

Sprawność europejska

Weight 36,08 kg
CN 85044086

EcoFlow PowerOcean (three-phase installation)

EcoFlow PowerOcean is an innovative, modular solution for residential photovoltaic systems with energy storage, designed for three-phase systems. It enables energy independence through flexible configuration, high safety, and intelligent energy management, offering the ability to expand the system at any time.

Key features of EcoFlow PowerOcean (three-phase installation):

  • Modular design with expandable energy storage from 5.1 kWh to 15.3 kWh (depending on the model).
  • High maximum output power from 3,300 W to 9,900 W, capable of powering an entire home.
  • Safety provided by LFP batteries and integrated protection systems (e.g., fire, overcurrent, and short-circuit protection).
  • Intelligent control and monitoring via the EcoFlow Pro web portal and mobile apps.
  • IP65 rating for dust and water resistance, allowing installation both indoors and outdoors.
  • Wide operating temperature range from -20 to 50°C, ensuring stable performance in various climates.

Who is this a good choice for?

EcoFlow PowerOcean is an ideal choice for homeowners looking for a reliable and scalable energy storage solution for three-phase photovoltaic installations. It suits households aiming to maximize self-consumption, ensure backup power during grid outages, and reduce energy bills. This is a premium solution offering investment flexibility and advanced energy management features.

Datasheet EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Datasheet.pdf Manual EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Manual.pdf Declaration of confirmity EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Declaration-of-confirmity.pdf Comatibility letter EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Comatibility-letter.pdf Installation guide EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Installation-guide.pdf

EcoFlow PowerOcean Hybrid Inverter EF HD-P3-6K0-S1 EF HD-P3-8K0-S1 EF HD-P3-10K-S1 EF HD-P3-12K-S1
DC Input (PV)
Max. PV array power (W) 10000 12000 14000 16000
Max. input voltage (V) 1000 1000 1000 1000
MPPT operating voltage range (V) 200-850 200-850 200-850 200-850
Start-up voltage (V) 160 160 160 160
Nominal input voltage (V) 600 600 600 600
Max. power per MPPT (W) 5000 6000 7000 8000
Max. input current per MPPT (A) 16 16 16 16
Max. short-circuit current per MPPT (A) 24 24 24 24
Number of strings per MPPT 1 1 1 1
Number of MPPTs 2 2 2 2
Surge protection category II II II II
DC Input (Battery)
Max. charging power (W) 6000 8000 10000 12000
Max. discharging power (W) 6000 8000 10000 12000
Max. continuous charging current (A) 12.5 12.5 12.5 15
Max. continuous discharging current (A) 12.5 12.5 12.5 15
Nominal voltage (V) 800 800 800 800
Max. battery capacity (kWh) 45.9 45.9 45.9 45.9
AC Input
Surge protection category III III III III
Nominal apparent power from the grid (VA) 12000 16000 16000 16000
Max. apparent power from the grid (VA) 12000 16000 16000 16000
Nominal input voltage (V) 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE
Max. AC current from the grid (A) 17.4 23.1 23.1 23.1
Nominal frequency (Hz) 50/60 50/60 50/60 50/60
Grid connection 3L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE
Surge protection category III III III III
AC Output (Grid-tied operation)
Rated output apparent power to grid (VA) 6000 8000 10000 12000
Max. output apparent power to grid (VA) 6000 8000 10000 12000
Rated output voltage (V) 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE
Nominal frequency (Hz) 50/60 50/60 50/60 50/60
Rated output current (A) 8.7 11.5 14.4 17.4
Total harmonic distortion (at rated power) <3% <3% <3% <3%
Power factor -0.8 … 1 … +0.8 -0.8 … 1 … +0.8 -0.8 … 1 … +0.8 -0.8 … 1 … +0.8
AC Output (Backup power)
Rated apparent power (VA) 6000 8000 10000 12000
Max. apparent power (VA) 7200 for 1 s 9600 for 1 s 12000 for 1 s 14400 for 1 s
Rated output voltage (V) 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE
Nominal frequency (Hz) 50/60 50/60 50/60 50/60
Rated output current (A) 8.7 11.5 14.4 17.4
Max. AC output current to the grid (A) 8.7 11.5 14.4 17.4
Max. output current (A) 10.4 for 1 s 13.9 for 1 s 17.4 for 1 s 20.9 for 1 s
Total voltage harmonic distortion (with linear load at rated power) <3% <3% <3% <3%
Residual current monitoring Integrated Integrated Integrated Integrated
PV insulation resistance detection Integrated Integrated Integrated Integrated
Anti-islanding protection Integrated Integrated Integrated Integrated
PV reverse polarity protection Integrated Integrated Integrated Integrated
AC overcurrent protection Integrated Integrated Integrated Integrated
Short-circuit protection for backup load Integrated Integrated Integrated Integrated
AC surge protection Integrated Integrated Integrated Integrated
DC isolator | | | |
Remote shutdown | | | |
Efficiency
Maximum efficiency 97.6% 97.6% 97.6% 97.6%
Max. MPPT efficiency 99.9% 99.9% 99.9% 99.9%
General data
Certifications CE/CB/TUV marking CE/CB/TUV marking CE/CB/TUV marking CE/CB/TUV marking
Safety standards IEC/EN62109-1, IEC/EN62109-2 IEC/EN62109-1, IEC/EN62109-2 IEC/EN62109-1, IEC/EN62109-2 IEC/EN62109-1, IEC/EN62109-2
Grid connection standards CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105
EMC EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328
Topology Non-isolated Non-isolated Non-isolated Non-isolated
Operating temperature range (°C) From -20 to 50 From -20 to 50 From -20 to 50 From -20 to 50
Storage temperature (°C) From -30 to 60 From -30 to 60 From -30 to 60 From -30 to 60
Operating relative humidity 0%-100% (condensing) 0%-100% (condensing) 0%-100% (condensing) 0%-100% (condensing)
Noise emission (dB) <35 <35 <35 <35
Max. operating altitude above sea level (m) 3000 3000 3000 3000
Weight (kg) Approx. 29.6 kg Approx. 29.6 kg Approx. 29.6 kg Approx. 29.6 kg
Dimensions (W x D x H) (mm) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover)
Protection rating IP65 IP65 IP65 IP65
Night-time self-consumption (W) <25 <25 <25 <25
Cooling method Natural convection Natural convection Natural convection Natural convection
Communication method RS485 (for meter) and CAN (for BMS) and Wi-Fi, Bluetooth, LAN and 4G (optional) RS485 (for meter) and CAN (for BMS) and Wi-Fi, Bluetooth, LAN and 4G (optional) RS485 (for meter) and CAN (for BMS) and Wi-Fi, Bluetooth, LAN and 4G (optional) RS485 (for meter) and CAN (for BMS) and Wi-Fi, Bluetooth, LAN and 4G (optional)
Wi‑Fi frequency range (MHz) 2412-2472 (20) / 2422-2462 (40) 2412-2472 (20) / 2422-2462 (40) 2412-2472 (20) / 2422-2462 (40) 2412-2472 (20) / 2422-2462 (40)
Max. output power (dBm) 18.54 18.54 18.54 18.54
Bluetooth frequency range (MHz) 2402-2480 2402-2480 2402-2480 2402-2480
Max. output power (dBm) 7.19 7.19 7.19 7.19
Pollution degree PD3 PD3 PD3 PD3
Environmental category Outdoor/Indoor Outdoor/Indoor Outdoor/Indoor Outdoor/Indoor

Official distribution

Other brands in our portfolio