Inverter – ECOFLOW – EF HD-P3-10K-S1 + Meter EFA-ADL400-CT – hybrid – HV
| Rated power | |
|---|---|
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net depth | |
| CAN | |
| RS485 | |
| SPD Type II | |
| SPD Typ III | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Sprawność europejska | |
| CN | 85044086 |
Gross
Product details
| Rated power | |
|---|---|
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net depth | |
| CAN | |
| RS485 | |
| SPD Type II | |
| SPD Typ III | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Sprawność europejska | |
| CN | 85044086 |
EcoFlow PowerOcean EF HD-P3-12K-S1 + Energy Meter EFA-ADL400-CT
EcoFlow PowerOcean is an innovative, modular solution for home photovoltaic installations with energy storage, designed for three-phase systems. It enables energy independence through flexible configuration, high safety standards and intelligent energy management, with the option to expand the system at any time.
Key features of EcoFlow PowerOcean (three-phase installation):
- Modular design allowing energy storage expansion from 5.1 kWh to 15.3 kWh (depending on the model).
- High maximum output power from 3,300 W to 9,900 W, capable of powering an entire home.
- Safety ensured by lithium iron phosphate (LFP) batteries and integrated protection systems (including fire, overcurrent and short-circuit protection).
- Intelligent control and monitoring via the EcoFlow Pro web portal and mobile apps.
- IP65 rating for dust and water resistance, allowing for both indoor and outdoor installation.
- Wide operating temperature range from -20 to 50°C, ensuring stable performance in various climates.
Who is this a good choice for?
EcoFlow PowerOcean is an excellent option for homeowners looking for a reliable and scalable energy storage solution for three-phase solar installations. It suits households aiming to maximize self-consumption, provide backup power during grid outages and reduce energy bills. This is a premium solution offering investment flexibility and advanced energy management features.
EcoFlow EFA-ADL400-CT Energy Meter
The EcoFlow EFA-ADL400-CT energy meter enables seamless integration with EcoFlow PowerOcean systems, allowing precise energy management. It provides tailored solutions that increase control over consumption and generation, improving overall system performance.
Key features of the EcoFlow EFA-ADL400-CT Energy Meter:
- Available in single-phase and three-phase models, supporting rated currents from 80 A to 200 A.
- RS485 communication for efficient data exchange.
- Option of built-in or external current transformers (CTs).
- Designed for DIN-rail mounting for easy installation.
- Compatible with a wide range of EcoFlow products, including PowerOcean, PowerOcean DC Fit, PowerPulse and PowerGlow.
- Special recommendation for users in the United Kingdom (120 A meter).
Who is this a good choice for?
The EcoFlow EFA-ADL400-CT energy meter is ideal for users of EcoFlow PowerOcean photovoltaic systems who need an advanced tool for monitoring and managing energy. It works well in both residential and commercial installations where measurement accuracy, easy integration and the ability to tailor the device to the specific system and user needs are important.
| EcoFlow PowerOcean hybrid inverter | EF HD-P3-6K0-S1 | EF HD-P3-8K0-S1 | EF HD-P3-10K-S1 | EF HD-P3-12K-S1 |
| DC input (PV) | ||||
| Max. PV array power (W) | 10000 | 12000 | 14000 | 16000 |
| Max. input voltage (V) | 1000 | 1000 | 1000 | 1000 |
| MPPT operating voltage range (V) | 200-850 | 200-850 | 200-850 | 200-850 |
| Start-up voltage (V) | 160 | 160 | 160 | 160 |
| Nominal input voltage (V) | 600 | 600 | 600 | 600 |
| Max. power per MPPT (W) | 5000 | 6000 | 7000 | 8000 |
| Max. input current per MPPT (A) | 16 | 16 | 16 | 16 |
| Max. short-circuit current per MPPT (A) | 24 | 24 | 24 | 24 |
| Number of strings per MPPT | 1 | 1 | 1 | 1 |
| Number of MPPTs | 2 | 2 | 2 | 2 |
| Surge protection category | II | II | II | II |
| DC input (battery) | ||||
| Max. charging power (W) | 6000 | 8000 | 10000 | 12000 |
| Max. discharging power (W) | 6000 | 8000 | 10000 | 12000 |
| Max. continuous charging current (A) | 12.5 | 12.5 | 12.5 | 15 |
| Max. continuous discharging current (A) | 12.5 | 12.5 | 12.5 | 15 |
| Nominal voltage (V) | 800 | 800 | 800 | 800 |
| Max. battery capacity (kWh) | 45.9 | 45.9 | 45.9 | 45.9 |
| AC input | ||||
| Surge protection category | III | III | III | III |
| Rated apparent power from the grid (VA) | 12000 | 16000 | 16000 | 16000 |
| Max. apparent power from the grid (VA) | 12000 | 16000 | 16000 | 16000 |
| Rated input voltage (V) | 230/400, 3L+N+PE | 230/400, 3L+N+PE | 230/400, 3L+N+PE | 230/400, 3L+N+PE |
| Max. AC current from the grid (A) | 17.4 | 23.1 | 23.1 | 23.1 |
| Rated frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
| Grid connection | 3L+N+PE | 3L+N+PE | 3L+N+PE | 3L+N+PE |
| Surge protection category | III | III | III | III |
| AC output (grid operation) | ||||
| Rated output apparent power to the grid (VA) | 6000 | 8000 | 10000 | 12000 |
| Max. output apparent power to the grid (VA) | 6000 | 8000 | 10000 | 12000 |
| Rated output voltage (V) | 230/400, 3L+N+PE | 230/400, 3L+N+PE | 230/400, 3L+N+PE | 230/400, 3L+N+PE |
| Rated frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
| Rated output current (A) | 8.7 | 11.5 | 14.4 | 17.4 |
| Total harmonic distortion (at rated power) | <3% | <3% | <3% | <3% |
| Power factor | -0.8…1…+0.8 | -0.8…1…+0.8 | -0.8…1…+0.8 | -0.8…1…+0.8 |
| AC output (backup power) | ||||
| Rated apparent power (VA) | 6000 | 8000 | 10000 | 12000 |
| Max. apparent power (VA) | 7200 for 1 s | 9600 for 1 s | 12000 for 1 s | 14400 for 1 s |
| Rated output voltage (V) | 230/400, 3L+N+PE | 230/400, 3L+N+PE | 230/400, 3L+N+PE | 230/400, 3L+N+PE |
| Rated frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
| Rated output current (A) | 8.7 | 11.5 | 14.4 | 17.4 |
| Max. AC output current to the grid (A) | 8.7 | 11.5 | 14.4 | 17.4 |
| Max. output current (A) | 10.4 for 1 s | 13.9 for 1 s | 17.4 for 1 s | 20.9 for 1 s |
| Total harmonic distortion of voltage (with linear load at rated power) | <3% | <3% | <3% | <3% |
| Residual current monitoring | Integrated | Integrated | Integrated | Integrated |
| PV insulation resistance detection | Integrated | Integrated | Integrated | Integrated |
| Anti-islanding protection | Integrated | Integrated | Integrated | Integrated |
| PV reverse polarity protection | Integrated | Integrated | Integrated | Integrated |
| AC overcurrent protection | Integrated | Integrated | Integrated | Integrated |
| Backup load short-circuit protection | Integrated | Integrated | Integrated | Integrated |
| AC surge protection | Integrated | Integrated | Integrated | Integrated |
| DC disconnect | | | | | | | | |
| Remote shutdown | | | | | | | | |
| Efficiency | ||||
| Maximum efficiency | 97.6% | 97.6% | 97.6% | 97.6% |
| Maximum MPPT efficiency | 99.9% | 99.9% | 99.9% | 99.9% |
| General information | ||||
| Certifications | CE/CB/TUV marking | CE/CB/TUV marking | CE/CB/TUV marking | CE/CB/TUV marking |
| Safety standards | IEC/EN62109-1, IEC/EN62109-2 | IEC/EN62109-1, IEC/EN62109-2 | IEC/EN62109-1, IEC/EN62109-2 | IEC/EN62109-1, IEC/EN62109-2 |
| Grid connection standards | CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 | CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 | CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 | CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 |
| EMC | EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 | EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 | EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 | EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 |
| Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
| Operating temperature range (°C) | -20 to 50 | -20 to 50 | -20 to 50 | -20 to 50 |
| Storage temperature (°C) | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 |
| Operating relative humidity | 0%-100% (condensation) | 0%-100% (condensation) | 0%-100% (condensation) | 0%-100% (condensation) |
| Noise emission (dB) | <35 | <35 | <35 | <35 |
| Max. operating altitude above sea level (m) | 3000 | 3000 | 3000 | 3000 |
| Weight (kg) | Approx. 29.6 kg | Approx. 29.6 kg | Approx. 29.6 kg | Approx. 29.6 kg |
| Dimensions (W x D x H) (mm) | 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) | 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) | 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) | 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) |
| Ingress protection | IP65 | IP65 | IP65 | IP65 |
| Nighttime self-consumption (W) | <25 | <25 | <25 | <25 |
| Cooling method | Natural convection | Natural convection | Natural convection | Natural convection |
| Communication methods | RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional) | RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional) | RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional) | RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional) |
| Wi‑Fi frequency range (MHz) | 2412-2472 (20) / 2422-2462 (40), | 2412-2472 (20) / 2422-2462 (40), | 2412-2472 (20) / 2422-2462 (40), | 2412-2472 (20) / 2422-2462 (40), |
| Maximum output power (dBm) | 18.54 | 18.54 | 18.54 | 18.54 |
| Bluetooth frequency range (MHz) | 2402-2480, | 2402-2480, | 2402-2480, | 2402-2480, |
| Maximum output power (dBm) | 7.19 | 7.19 | 7.19 | 7.19 |
| Pollution degree | PD3 | PD3 | PD3 | PD3 |
| Environmental category | Outdoor/indoor | Outdoor/indoor | Outdoor/indoor | Outdoor/indoor |
| Parameter | Energy meter EFA-ADL400-CT |
|---|---|
| General information | |
| SKU | EFA-ADL400-CT |
| Dimensions (mm) | 72 x 90 x 65 |
| Rated current (A) | 80 A |
| Installation | DIN rail |
| Communication | RS485 |
| Number of phases | Three-phase |
| Current measurement | Built-in current transformer |
| Compatibility | |
| Compatible products | EcoFlow PowerOcean (three-phase), EcoFlow PowerOcean Plus (three-phase), PowerOcean DC Fit, PowerPulse, PowerPulse 2, PowerGlow |
All specifications and descriptions shown may differ from the actual product specifications. EcoFlow reserves the right to make changes and corrections to the product presented and described here at any time without prior notice of such changes.