Inverter – ECOFLOW – EF HD-P3-10K-S1 + Meter EFA-ADL400-CT – hybrid – HV

SKU: F20W4 EAN: 2010000036099
Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net depth

CAN

RS485

SPD Type II

SPD Typ III

MPPT voltage range

Maksymalny prąd wejściowy na MPPT [A]

Sprawność europejska

CN 85044086
Price 0,30 
Gross

0,30 
Gross

0,30 
Gross

Datasheet EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Datasheet.pdf Manual EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Manual.pdf Declaration of confirmity EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Declaration-of-confirmity.pdf Installation guide EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Installation-guide.pdf Comatibility letter EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Comatibility-letter.pdf Datasheet EcoFlow - EFA-ADL400-CT EcoFlow-EFA-ADL400-CT-Datasheet.pdf Manual EcoFlow - EFA-ADL400-CT EcoFlow-EFA-ADL400-CT-Manual.pdf

Product details

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net depth

CAN

RS485

SPD Type II

SPD Typ III

MPPT voltage range

Maksymalny prąd wejściowy na MPPT [A]

Sprawność europejska

CN 85044086

EcoFlow PowerOcean EF HD-P3-12K-S1 + Energy Meter EFA-ADL400-CT

EcoFlow PowerOcean is an innovative, modular solution for home photovoltaic installations with energy storage, designed for three-phase systems. It enables energy independence through flexible configuration, high safety standards and intelligent energy management, with the option to expand the system at any time.

Key features of EcoFlow PowerOcean (three-phase installation):

  • Modular design allowing energy storage expansion from 5.1 kWh to 15.3 kWh (depending on the model).
  • High maximum output power from 3,300 W to 9,900 W, capable of powering an entire home.
  • Safety ensured by lithium iron phosphate (LFP) batteries and integrated protection systems (including fire, overcurrent and short-circuit protection).
  • Intelligent control and monitoring via the EcoFlow Pro web portal and mobile apps.
  • IP65 rating for dust and water resistance, allowing for both indoor and outdoor installation.
  • Wide operating temperature range from -20 to 50°C, ensuring stable performance in various climates.

Who is this a good choice for?

EcoFlow PowerOcean is an excellent option for homeowners looking for a reliable and scalable energy storage solution for three-phase solar installations. It suits households aiming to maximize self-consumption, provide backup power during grid outages and reduce energy bills. This is a premium solution offering investment flexibility and advanced energy management features.

EcoFlow EFA-ADL400-CT Energy Meter

The EcoFlow EFA-ADL400-CT energy meter enables seamless integration with EcoFlow PowerOcean systems, allowing precise energy management. It provides tailored solutions that increase control over consumption and generation, improving overall system performance.

Key features of the EcoFlow EFA-ADL400-CT Energy Meter:

  • Available in single-phase and three-phase models, supporting rated currents from 80 A to 200 A.
  • RS485 communication for efficient data exchange.
  • Option of built-in or external current transformers (CTs).
  • Designed for DIN-rail mounting for easy installation.
  • Compatible with a wide range of EcoFlow products, including PowerOcean, PowerOcean DC Fit, PowerPulse and PowerGlow.
  • Special recommendation for users in the United Kingdom (120 A meter).

Who is this a good choice for?

The EcoFlow EFA-ADL400-CT energy meter is ideal for users of EcoFlow PowerOcean photovoltaic systems who need an advanced tool for monitoring and managing energy. It works well in both residential and commercial installations where measurement accuracy, easy integration and the ability to tailor the device to the specific system and user needs are important.

Datasheet EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Datasheet.pdf Manual EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Manual.pdf Declaration of confirmity EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Declaration-of-confirmity.pdf Installation guide EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Installation-guide.pdf Comatibility letter EcoFlow PowerOcean EF HD-P3-6K0-S1 - EF HD-P3-12K-S1 EcoFlow-PowerOcean-EF-HD-P3-6K0-S1-EF-HD-P3-12K-S1-Comatibility-letter.pdf Datasheet EcoFlow - EFA-ADL400-CT EcoFlow-EFA-ADL400-CT-Datasheet.pdf Manual EcoFlow - EFA-ADL400-CT EcoFlow-EFA-ADL400-CT-Manual.pdf

EcoFlow PowerOcean hybrid inverter EF HD-P3-6K0-S1 EF HD-P3-8K0-S1 EF HD-P3-10K-S1 EF HD-P3-12K-S1
DC input (PV)
Max. PV array power (W) 10000 12000 14000 16000
Max. input voltage (V) 1000 1000 1000 1000
MPPT operating voltage range (V) 200-850 200-850 200-850 200-850
Start-up voltage (V) 160 160 160 160
Nominal input voltage (V) 600 600 600 600
Max. power per MPPT (W) 5000 6000 7000 8000
Max. input current per MPPT (A) 16 16 16 16
Max. short-circuit current per MPPT (A) 24 24 24 24
Number of strings per MPPT 1 1 1 1
Number of MPPTs 2 2 2 2
Surge protection category II II II II
DC input (battery)
Max. charging power (W) 6000 8000 10000 12000
Max. discharging power (W) 6000 8000 10000 12000
Max. continuous charging current (A) 12.5 12.5 12.5 15
Max. continuous discharging current (A) 12.5 12.5 12.5 15
Nominal voltage (V) 800 800 800 800
Max. battery capacity (kWh) 45.9 45.9 45.9 45.9
AC input
Surge protection category III III III III
Rated apparent power from the grid (VA) 12000 16000 16000 16000
Max. apparent power from the grid (VA) 12000 16000 16000 16000
Rated input voltage (V) 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE
Max. AC current from the grid (A) 17.4 23.1 23.1 23.1
Rated frequency (Hz) 50/60 50/60 50/60 50/60
Grid connection 3L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE
Surge protection category III III III III
AC output (grid operation)
Rated output apparent power to the grid (VA) 6000 8000 10000 12000
Max. output apparent power to the grid (VA) 6000 8000 10000 12000
Rated output voltage (V) 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE
Rated frequency (Hz) 50/60 50/60 50/60 50/60
Rated output current (A) 8.7 11.5 14.4 17.4
Total harmonic distortion (at rated power) <3% <3% <3% <3%
Power factor -0.8…1…+0.8 -0.8…1…+0.8 -0.8…1…+0.8 -0.8…1…+0.8
AC output (backup power)
Rated apparent power (VA) 6000 8000 10000 12000
Max. apparent power (VA) 7200 for 1 s 9600 for 1 s 12000 for 1 s 14400 for 1 s
Rated output voltage (V) 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE 230/400, 3L+N+PE
Rated frequency (Hz) 50/60 50/60 50/60 50/60
Rated output current (A) 8.7 11.5 14.4 17.4
Max. AC output current to the grid (A) 8.7 11.5 14.4 17.4
Max. output current (A) 10.4 for 1 s 13.9 for 1 s 17.4 for 1 s 20.9 for 1 s
Total harmonic distortion of voltage (with linear load at rated power) <3% <3% <3% <3%
Residual current monitoring Integrated Integrated Integrated Integrated
PV insulation resistance detection Integrated Integrated Integrated Integrated
Anti-islanding protection Integrated Integrated Integrated Integrated
PV reverse polarity protection Integrated Integrated Integrated Integrated
AC overcurrent protection Integrated Integrated Integrated Integrated
Backup load short-circuit protection Integrated Integrated Integrated Integrated
AC surge protection Integrated Integrated Integrated Integrated
DC disconnect | | | |
Remote shutdown | | | |
Efficiency
Maximum efficiency 97.6% 97.6% 97.6% 97.6%
Maximum MPPT efficiency 99.9% 99.9% 99.9% 99.9%
General information
Certifications CE/CB/TUV marking CE/CB/TUV marking CE/CB/TUV marking CE/CB/TUV marking
Safety standards IEC/EN62109-1, IEC/EN62109-2 IEC/EN62109-1, IEC/EN62109-2 IEC/EN62109-1, IEC/EN62109-2 IEC/EN62109-1, IEC/EN62109-2
Grid connection standards CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105 CE marking, EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPIREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105
EMC EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328 EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328
Topology Non-isolated Non-isolated Non-isolated Non-isolated
Operating temperature range (°C) -20 to 50 -20 to 50 -20 to 50 -20 to 50
Storage temperature (°C) -30 to 60 -30 to 60 -30 to 60 -30 to 60
Operating relative humidity 0%-100% (condensation) 0%-100% (condensation) 0%-100% (condensation) 0%-100% (condensation)
Noise emission (dB) <35 <35 <35 <35
Max. operating altitude above sea level (m) 3000 3000 3000 3000
Weight (kg) Approx. 29.6 kg Approx. 29.6 kg Approx. 29.6 kg Approx. 29.6 kg
Dimensions (W x D x H) (mm) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover) 588 x 175 x 380 (±1) (without cover), 588 x 175 x 455 (±1) (with cover)
Ingress protection IP65 IP65 IP65 IP65
Nighttime self-consumption (W) <25 <25 <25 <25
Cooling method Natural convection Natural convection Natural convection Natural convection
Communication methods RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional) RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional) RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional) RS485 (for meter) and CAN (for BMS) plus Wi‑Fi, Bluetooth, LAN and 4G (optional)
Wi‑Fi frequency range (MHz) 2412-2472 (20) / 2422-2462 (40), 2412-2472 (20) / 2422-2462 (40), 2412-2472 (20) / 2422-2462 (40), 2412-2472 (20) / 2422-2462 (40),
Maximum output power (dBm) 18.54 18.54 18.54 18.54
Bluetooth frequency range (MHz) 2402-2480, 2402-2480, 2402-2480, 2402-2480,
Maximum output power (dBm) 7.19 7.19 7.19 7.19
Pollution degree PD3 PD3 PD3 PD3
Environmental category Outdoor/indoor Outdoor/indoor Outdoor/indoor Outdoor/indoor
Parameter Energy meter EFA-ADL400-CT
General information
SKU EFA-ADL400-CT
Dimensions (mm) 72 x 90 x 65
Rated current (A) 80 A
Installation DIN rail
Communication RS485
Number of phases Three-phase
Current measurement Built-in current transformer
Compatibility
Compatible products EcoFlow PowerOcean (three-phase), EcoFlow PowerOcean Plus (three-phase), PowerOcean DC Fit, PowerPulse, PowerPulse 2, PowerGlow

All specifications and descriptions shown may differ from the actual product specifications. EcoFlow reserves the right to make changes and corrections to the product presented and described here at any time without prior notice of such changes.

Official distribution

Other brands in our portfolio