Datasheet Huawei SUN 2000-100KTL-M2 400/480VAC datasheet-huawei-sun-2000-100ktl-m2-400-480vac.pdf

Product details

Manufacturer

Rated power

MPPT

Net depth

Maximum output current [A]

Weight 96 kg
CN 8504408600

SUN2000-100KTL-M2

The SUN2000-100KTL-M2 by HUAWEI is a transformerless inverter for photovoltaic installations with a rated AC active power of 100 kW. The device offers 10 MPPT trackers and achieves a maximum efficiency of 98.6% at 400 V and 98.8% at 480 V. It supports intelligent I-V curve diagnostics and PV module string fault monitoring.

Key advantages of SUN2000-100KTL-M2

  • Output power: rated AC active power of 100 kW and maximum AC active power of 110 kW at cosφ = 1.
  • 10 MPPT circuits: a maximum of 2 inputs per MPPT and an MPPT operating voltage range of 200–1000 V.
  • Maximum efficiency: 98.6% at 400 V and 98.8% at 480 V.
  • PV string protection: AFCI arc fault protection, an intelligent DC string disconnector and type II surge protection devices on the DC and AC sides.
  • Diagnostics and communication: intelligent I-V curve diagnostics, RS485 and USB interfaces, and MBUS support requiring an isolation transformer.
  • IP66 protection rating: air cooling and an operating temperature range from -25 to 60°C.

Who is this a good choice for?

This is an option for owners of photovoltaic systems requiring an inverter with a rated AC active power of 100 kW. Users who need PV string monitoring have access to I-V curve diagnostics and fault monitoring, while those prioritizing system protection benefit from AFCI functionality, an intelligent DC string disconnector, and Type II surge protection devices.

Datasheet Huawei SUN 2000-100KTL-M2 400/480VAC datasheet-huawei-sun-2000-100ktl-m2-400-480vac.pdf

Parameter Value
Efficiency
Maximum efficiency (%) 98.6% @ 400 V, 98.8% @ 480 V
European efficiency (%) 98.4% @ 400 V, 98.6% @ 480 V
DC input data
Maximum input voltage (V) 1100
Maximum current per MPPT (A) 30
Maximum input current (A) 20
Maximum short-circuit current per MPPT (A) 40
Start-up voltage (V) 200 V
MPPT operating voltage range (V) 200 V ~ 1000 V
Rated input voltage (V) 600 V @ 400 Vac, 720 V @ 480 Vac
Number of MPPTs 10
Maximum number of inputs per MPPT 2
AC output data
Rated AC active power (W) 100.000 W
Maximum AC apparent power (VA) 110,000
Maximum AC active power at cosφ=1 (W) 110,000
Rated output voltage (V) 400 / 480
Output connection configuration 3W+(N)+PE
Rated AC grid frequency (Hz) 50 Hz / 60 Hz
Rated output current (A) 144.4 A @ 400 V, 120.3 A @ 480 V
Maximum output current (A) 160.4 @ 400 V, 133.7 @ 480 V
Adjustable power factor range 0.8 leading… 0.8 lagging
Maximum total harmonic distortion (%) < 3
Protection
Input-side disconnecting device Yes
Anti-islanding protection Yes
AC overcurrent protection Yes
DC reverse polarity protection Yes
PV module string fault monitoring Yes
DC surge protector Type II
AC surge protector Type II
DC insulation resistance detection Yes
Residual current monitoring unit (RCMU) Yes
Arc fault protection Yes
Smart DC string disconnector Yes
Communication
Display LED indicators; WLAN adapter + FusionSolar APP
RS485 Yes
USB Yes
Connectivity via Smart Dongle-4G 4G / 3G / 2G via Smart Dongle – 4G (optional)
Monitoring bus (MBUS) Yes (isolation transformer required)
Dimensions and weight
Dimensions (W × H × D) (mm) 1035 x 700 x 365
Weight with mounting bracket (kg) 93
Operating conditions
Operating temperature range (°C) -25°C ~ 60°C
Cooling method Air cooling
Maximum working height (m) 4000
Relative humidity (%) 0 ~ 100%
Protection rating IP66
General information
DC connector Amphenol HH4
AC connector Waterproof connector + OT/DT terminal
Structure Transformerless
Nighttime power consumption (W) < 3.5 W
Certificates
Certificates and standards EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 61727, IEC 60068, IEC 61683
Grid connection standards VDE-AR-N4105, EN 50549-1, EN 50549-2, RD 661, RD 1699, C10/11

Exceeding the maximum DC input voltage may damage the inverter. DC voltage outside the MPPT operating range may cause malfunctions.