Inverter – FRONIUS – Symo GEN24 6.0 Plus – hybrid – HV
Incl. VAT
Falownik Fronius Symo GEN24 6.0 plus, 6kW, hybrydowy, trójfazowy, 2 mppt, bez wyświetlacza, wifi
Product details
SYMO GEN24 PLUS
SYMO GEN24 PLUS is a series of hybrid inverters from Fronius designed for private households, with a rated AC output of 6–10 kW depending on the model. It combines energy management features with an integrated backup power function: PV Point or full backup power. Standard WLAN and Ethernet connectivity and the ability to integrate third-party components make it easy to connect the device to an energy management system.
Key benefits of SYMO GEN24 PLUS
- Backup power: PV Point with a nominal power of 3 kVA or full backup power of 6–10 kVA, depending on the model; switchover time below 90 seconds.
- Maximum efficiency 98.2%: European weighted efficiency is 97.7–97.9%, depending on the model.
- Two MPP trackers: usable MPP voltage range of 80–800 V and Dynamic Peak Manager function.
- Battery connection: DC voltage range of 160–500 V and maximum input current of 22 A.
- Communication and energy management: WLAN, two Ethernet LAN ports, Modbus interfaces, and a data logger and web server included.
- Installation indoors or outdoors: IP66 protection rating and ambient temperature range from -25 to +60 °C.
Who is this a good choice for?
SYMO GEN24 PLUS is designed for homeowners who want to manage energy from their photovoltaic system and use backup power functions. It is also an option for users planning to connect a battery and those who value communication with the system via WLAN or Ethernet.
| Parameter | SYMO GEN24 6.0 PLUS | SYMO GEN24 8.0 PLUS | SYMO GEN24 10.0 PLUS |
|---|---|---|---|
| DC input data | |||
| Number of MPP trackers | 2 | ||
| Maximum input current MPPT1 / MPPT2 (A) | 25 / 12,5 | ||
| Maximum module array short-circuit current MPPT1 / MPPT2 (A) | 37,5 / 18,75 | ||
| Input voltage range (V) | 80 - 1,000 | ||
| Rated input voltage (V) | 610 | ||
| Start-up voltage (V) | 80 | ||
| Usable MPP voltage range (V) | 80 V - 800 V | ||
| Number of strings MPPT1 / MPPT2 | 2 / 1 | ||
| Maximum PV generator power (kWpeak) | 9 | 12 | 15 |
| AC output data | |||
| Rated AC power (W) | 6,000 | 8,000 | 10,000 |
| Maximum output power (VA) | 6,000 | 8,000 | 10,000 |
| Maximum output current (A) | 16,4 | ||
| Grid connection and voltage range (V) | 3~NPE 400 / 230 or 3~NPE 380 / 220 (+20% / -30%) | ||
| Frequency and frequency range (Hz) | 50 / 60 (45 - 66) | ||
| Total harmonic distortion THD (%) | < 3,5 % | ||
| Power factor cos φ | 0.7 - 1 ind. / cap. | ||
| Backup power supply (V) | 3~NPE 400 V / 230 V | ||
| PV Point backup power and full backup power | |||
| Nominal output power of PV Point / full backup power supply (VA) | 3,000 / 6,000 | 3,000 / 8,000 | 3,000 / 10,000 |
| Nominal power per phase for full backup power (kVA) | 3,68 | ||
| PV Point connection (V) | 1~NPE 220 / 230 | ||
| Full backup power connection (V) | 3~NPE 400 / 230 or 3~NPE 380 / 220 | ||
| Switching time (s) | < 90 seconds | ||
| Battery connection | |||
| Number of DC connections | 1 | ||
| Maximum input current (A) | 22 | ||
| DC input voltage range (V) | 160 - 500 | ||
| Maximum input/output power (W) | 6,220 | 8,260 | 10,300 |
| Maximum AC-side charging power (W) | 6,000 | 8,000 | 10,000 |
| Compatible battery types | BYD Battery-Box Premium HVS/HVM | ||
| Dimensions and weight | |||
| Dimensions: height × width × depth (mm) | 594 x 527 x 180 | ||
| Inverter weight (kg) | 24 | ||
| General information | |||
| Protection rating | IP 66 | ||
| Protection class | 1 | ||
| Nighttime power losses (W) | < 10 | ||
| DC / AC overvoltage category | 2 / 3 | ||
| Inverter topology | Transformerless | ||
| Cooling | Adjustable forced ventilation | ||
| Installation | Indoor or outdoor installation | ||
| Backup power functions | PV Point or full backup | ||
| Operating conditions | |||
| Ambient temperature range (°C) | -25 - +60 °C | ||
| Permissible air humidity (%) | 0 - 100 % | ||
| Maximum installation height (m) | 3,000 / 4,000 (unrestricted / restricted voltage range) | ||
| Connection terminals | |||
| DC terminals for PV | 3x DC+ and 3x DC-, plug-in spring terminals | ||
| Cross-sectional area of DC cables for PV (mm²) | 2,5 - 10 | ||
| DC battery clamps | 1x BATT+ and 1x BATT-, plug-in spring terminals | ||
| Cross-sectional area of DC cables to the battery (mm²) | 2,5 - 10 | ||
| AC terminals | 5x AC, plug-in spring terminals | ||
| AC conductor cross-section (mm²) | 1,5 - 10 | ||
| Emergency power supply terminals | 3x backup power plug-in spring terminals 1.5mm² - 10mm² | ||
| Emergency power supply cable cross-section (mm²) | 1,5 - 10 | ||
| PE terminals | 5x PE screw terminals 2.5 - 16 mm² | ||
| PE conductor cross-section (mm²) | 2,5 - 16 | ||
| Efficiency | |||
| Maximum efficiency (%) | 98,2 | ||
| European weighted efficiency (%) | 97,7 | 97,8 | 97,9 |
| MPP tracking efficiency (%) | > 99,9 % | ||
| Protection | |||
| DC insulation measurement | Operating point shift, output power limitation | ||
| Behavior during overload | Yes | ||
| DC disconnector | Yes | ||
| Reverse polarity protection | Yes | ||
| Interfaces | |||
| WLAN / 2x Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) | ||
| 6 digital inputs/outputs + 6 digital inputs | Interface for remote control receiver, energy management | ||
| USB 2.0 supply current, Type A socket (A) | 1 | ||
| WSD emergency stop | Yes | ||
| Data logger and web server | Included | ||
| 2x RS485 | Modbus RTU SunSpec (third-party supplier) / Fronius Smart Meter, battery, Fronius Ohmpilot | ||
| Certificates | |||
| Certificates and compliance with standards | IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126, VDE AR-N4105, AS/NZS 4777,2, EN 50549, CEI 0-21, G 98, R25 | ||
The maximum battery input/output power depends on the connected battery. Overvoltage category in accordance with IEC 62109-1. Battery compatibility does not include HVS 12.8 and HVM 8.3.