Inverter – FRONIUS – Symo GEN24 6.0 Plus – hybrid – HV

SKU: 4,210,153,002 EAN: 9007947330697
Manufacturer

Net depth

Weight 28 kg
Price 2 501,62 €
Incl. VAT

2 501,62 €
Incl. VAT

In stock:

5 pcs
Log in to place an order

Falownik Fronius Symo GEN24 6.0 plus, 6kW, hybrydowy, trójfazowy, 2 mppt, bez wyświetlacza, wifi

2 501,62 €
Incl. VAT

In stock:

5 pcs
Log in to place an order

Product details

Manufacturer

Net depth

Weight 28 kg

SYMO GEN24 PLUS

SYMO GEN24 PLUS is a series of hybrid inverters from Fronius designed for private households, with a rated AC output of 6–10 kW depending on the model. It combines energy management features with an integrated backup power function: PV Point or full backup power. Standard WLAN and Ethernet connectivity and the ability to integrate third-party components make it easy to connect the device to an energy management system.

Key benefits of SYMO GEN24 PLUS

  • Backup power: PV Point with a nominal power of 3 kVA or full backup power of 6–10 kVA, depending on the model; switchover time below 90 seconds.
  • Maximum efficiency 98.2%: European weighted efficiency is 97.7–97.9%, depending on the model.
  • Two MPP trackers: usable MPP voltage range of 80–800 V and Dynamic Peak Manager function.
  • Battery connection: DC voltage range of 160–500 V and maximum input current of 22 A.
  • Communication and energy management: WLAN, two Ethernet LAN ports, Modbus interfaces, and a data logger and web server included.
  • Installation indoors or outdoors: IP66 protection rating and ambient temperature range from -25 to +60 °C.

Who is this a good choice for?

SYMO GEN24 PLUS is designed for homeowners who want to manage energy from their photovoltaic system and use backup power functions. It is also an option for users planning to connect a battery and those who value communication with the system via WLAN or Ethernet.

ParameterSYMO GEN24 6.0 PLUSSYMO GEN24 8.0 PLUSSYMO GEN24 10.0 PLUS
DC input data
Number of MPP trackers2
Maximum input current MPPT1 / MPPT2 (A)25 / 12,5
Maximum module array short-circuit current MPPT1 / MPPT2 (A)37,5 / 18,75
Input voltage range (V)80 - 1,000
Rated input voltage (V)610
Start-up voltage (V)80
Usable MPP voltage range (V)80 V - 800 V
Number of strings MPPT1 / MPPT22 / 1
Maximum PV generator power (kWpeak)91215
AC output data
Rated AC power (W)6,0008,00010,000
Maximum output power (VA)6,0008,00010,000
Maximum output current (A)16,4
Grid connection and voltage range (V)3~NPE 400 / 230 or 3~NPE 380 / 220 (+20% / -30%)
Frequency and frequency range (Hz)50 / 60 (45 - 66)
Total harmonic distortion THD (%)< 3,5 %
Power factor cos φ0.7 - 1 ind. / cap.
Backup power supply (V)3~NPE 400 V / 230 V
PV Point backup power and full backup power
Nominal output power of PV Point / full backup power supply (VA)3,000 / 6,0003,000 / 8,0003,000 / 10,000
Nominal power per phase for full backup power (kVA)3,68
PV Point connection (V)1~NPE 220 / 230
Full backup power connection (V)3~NPE 400 / 230 or 3~NPE 380 / 220
Switching time (s)< 90 seconds
Battery connection
Number of DC connections1
Maximum input current (A)22
DC input voltage range (V)160 - 500
Maximum input/output power (W)6,2208,26010,300
Maximum AC-side charging power (W)6,0008,00010,000
Compatible battery typesBYD Battery-Box Premium HVS/HVM
Dimensions and weight
Dimensions: height × width × depth (mm)594 x 527 x 180
Inverter weight (kg)24
General information
Protection ratingIP 66
Protection class1
Nighttime power losses (W)< 10
DC / AC overvoltage category2 / 3
Inverter topologyTransformerless
CoolingAdjustable forced ventilation
InstallationIndoor or outdoor installation
Backup power functionsPV Point or full backup
Operating conditions
Ambient temperature range (°C)-25 - +60 °C
Permissible air humidity (%)0 - 100 %
Maximum installation height (m)3,000 / 4,000 (unrestricted / restricted voltage range)
Connection terminals
DC terminals for PV3x DC+ and 3x DC-, plug-in spring terminals
Cross-sectional area of DC cables for PV (mm²)2,5 - 10
DC battery clamps1x BATT+ and 1x BATT-, plug-in spring terminals
Cross-sectional area of DC cables to the battery (mm²)2,5 - 10
AC terminals5x AC, plug-in spring terminals
AC conductor cross-section (mm²)1,5 - 10
Emergency power supply terminals3x backup power plug-in spring terminals 1.5mm² - 10mm²
Emergency power supply cable cross-section (mm²)1,5 - 10
PE terminals5x PE screw terminals 2.5 - 16 mm²
PE conductor cross-section (mm²)2,5 - 16
Efficiency
Maximum efficiency (%)98,2
European weighted efficiency (%)97,797,897,9
MPP tracking efficiency (%)> 99,9 %
Protection
DC insulation measurementOperating point shift, output power limitation
Behavior during overloadYes
DC disconnectorYes
Reverse polarity protectionYes
Interfaces
WLAN / 2x Ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 digital inputs/outputs + 6 digital inputsInterface for remote control receiver, energy management
USB 2.0 supply current, Type A socket (A)1
WSD emergency stopYes
Data logger and web serverIncluded
2x RS485Modbus RTU SunSpec (third-party supplier) / Fronius Smart Meter, battery, Fronius Ohmpilot
Certificates
Certificates and compliance with standardsIEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126, VDE AR-N4105, AS/NZS 4777,2, EN 50549, CEI 0-21, G 98, R25

The maximum battery input/output power depends on the connected battery. Overvoltage category in accordance with IEC 62109-1. Battery compatibility does not include HVS 12.8 and HVM 8.3.

Official distribution