Inverter – SOLAREDGE – SE120K-RW08IBNM4+3SESUK

SKU: SE120K-RW08IBNM4+3SESUK EAN: 5905515611862
Manufacturer

Net depth

Weight 113,75 kg
Price 6 232,55 €
Incl. VAT

6 232,55 €
Incl. VAT

In stock:

5 pcs
Log in to place an order

6 232,55 €
Incl. VAT

In stock:

5 pcs
Log in to place an order

Product details

Manufacturer

Net depth

Weight 113,75 kg

SE50K / SE66.6K / SE90K / SE100K / SE120K

The SolarEdge series of three-phase inverters with synergy technology offers a rated active AC output power of 50 to 120 kW, depending on the model. The system consists of 2–3 synergy units and a synergy manager. The IP65 protection rating allows outdoor and indoor installation.

Key benefits of SE50K / SE66.6K / SE90K / SE100K / SE120K

  • AC output power 50–120 kW — rated active power range covering models for 400 V grids and a 120 kW variant for 480 V grids.
  • Synergy technology — 2–3 synergic units in the system, depending on the model.
  • IP65 protection rating — can be installed indoors or outdoors using the included bracket.
  • Operating temperature range from −40 to +60°C — with power derating according to the manufacturer’s specifications.
  • Cooling with a replaceable fan — noise emissions below 67 dBA.
  • DC inputs with MC4 connectors — 8–12 pairs per inverter and 4 pairs per synergy unit; only MC4 connectors manufactured by Stäubli are permitted.

Who is this a good choice for?

This is an option for installation owners requiring a three-phase inverter with a rated AC output power of 50–120 kW, matched to a 400 V or 480 V grid. The series also meets the needs of users planning to install the device indoors or outdoors, in accordance with its IP65 protection rating.

ParameterSE50KSE66.6KSE90KSE100KSE120K
AC output data
Rated active AC output power (W)50000(2)6660090000100000120000
Maximum AC apparent output power (VA)50000(2)6660090000100000120000
Grid voltage (V)400480
DC input data
DC input connectors — inverter / synergy unit8/4 pairs of MC412/4 pairs MC4
Installation parameters
Number of synergic units in the system23
AC cable materialAluminium or copper
Maximum AC conductor cross-section — phase / ground (mm²)120 / 70
AC cable outer diameter — phase / grounding (mm)30–50 / 12–20
InstallationIncluded bracket
Dimensions and weight
Synergic unit dimensions — H × W × D (mm)558 x 328 x 273
Synergy Manager dimensions — H × W × D (mm)360 x 560 x 295
Synergic unit weight (kg)32
Synergy Manager weight (kg)18
Operating conditions
Operating temperature range (°C)From -40 to +60(8)
CoolingFan (replaceable)
Noise emission (dBA)< 67
Degree of protectionIP65 – outdoors and indoors
Installation locationOutdoors and indoors

Only MC4 connectors manufactured by Stäubli are permitted. Power derating applies across the operating temperature range in accordance with the manufacturer's documentation.

Official distribution