Inverter – FRONIUS – Symo GEN24 4.0 Plus SC – hybrid – HV
Incl. VAT
Product details
Symo GEN24 SC
Symo GEN24 SC is a series of three-phase photovoltaic inverters with power ratings of 3–12 kW, equipped with two maximum power point trackers (MPPT). The built-in PV Point function provides basic backup power, while open interfaces enable integration with components from Fronius and other manufacturers. Active cooling helps extend the inverter’s service life.
Key benefits of Symo GEN24 SC
- Rated AC power 3–12 kW and a maximum efficiency of 98.1–98.3%, depending on the model.
- Two MPPT systems with an operating MPP voltage range of 80–800 V and a DC input voltage range of 80–1000 V.
- Basic backup power supply PV Point as a built-in function of the inverter.
- Protection rating IP66, indoor and outdoor installation and an ambient temperature range from -25 to +60°C.
- WLAN connectivity, two Ethernet LAN ports and two RS485 interfaces; support for Fronius Solar.web, Modbus TCP SunSpec and Fronius Solar API, as well as a built-in data logger and web server.
- Integrated protection: DC insulation measurement, DC disconnector, reverse polarity protection, arc detection and WSD emergency shutdown.
Who is this a good choice for?
Symo GEN24 SC is designed for homeowners looking for an inverter for a photovoltaic system with basic PV Point backup power. Users who need to monitor system operation and integrate additional components benefit from open interfaces, a built-in data logger, and support for Fronius Solar.web.
| Parameter | Symo GEN24 4.0 Plus SC |
|---|---|
| Number of MPPT trackers | 2 |
| DC input voltage range (V) | 80 – 1,000 |
| Rated input voltage (V) | 610 |
| Grid feed-in start voltage (V) | 80 |
| Usable MPP voltage range (V) | 80 – 800 |
| MPP voltage range at rated power (V) | 150 – 800 |
| Maximum total usable DC power (W) | 4,180 |
| Maximum total PV generator power (Wp) | 6,000 |
| Maximum usable input current MPPT 1 (A) | 14 |
| Maximum PV generator short-circuit current MPPT 1 (A) | 20 |
| Number of DC connections MPPT 1 | 2 |
| Maximum usable DC power MPPT 1 (W) | 4,180 |
| Maximum PV generator power MPPT 1 (Wp) | 6,000 |
| Maximum usable input current MPPT 2 (A) | 14 |
| Maximum PV generator short-circuit current MPPT 2 (A) | 20 |
| Number of DC MPPT connections 2 | 1 |
| Maximum usable DC power MPPT 2 (W) | 4,180 |
| Maximum PV generator power MPPT 2 (Wp) | 6,000 |
| Rated AC active power (W) | 4,000 |
| Apparent power (VA) | 4,000 |
| Maximum output power (VA) | 4,000 |
| Rated AC output current at 380 V (A) | 6,1 |
| Rated AC output current at 400 V (A) | 5,8 |
| Grid connection (V) | 3~ NPE 400/230 or 3~ NPE 380/220 (+20%/-30%) |
| Rated frequency and frequency range (Hz) | 50/60 (45 – 65) |
| Total harmonic distortion (%) | < 3,5 |
| Power factor cos φ | 0.7 – 1 ind. / cap. |
| PV Point rated output power (VA) | 3,000 |
| PV Point connection (V) | 1~ NPE 220/230 |
| PV Point switchover time (s) | ~15 |
| Number of battery DC inputs | 1 |
| Maximum battery input current (A) | 14 |
| Battery input voltage range (V) | 160 – 700 |
| Battery DC terminals | 1x BATT+ and 1x BATT- push-in spring terminals 2.5 – 10 mm² |
| Maximum battery DC input/output power (W) | 4300 |
| Maximum AC-coupled charging power (W) | 4,000 |
| Compatible batteries | Fronius Reserva & BYD Battery-Box HVS/HVM, HVS+/HVM+ & LG FLEX |
| Maximum efficiency (%) | 98,1 |
| European efficiency (%) | 97,2 |
| MPP tracking efficiency (%) | > 99,9 |
| Nighttime power consumption (W) | <10 |
| Dimensions: height × width × depth (mm) | 530 × 474 × 165 |
| Inverter weight (kg) | 15.3 |
| Degree of protection | IP 66 |
| Protection class | 1 |
| DC/AC overvoltage category | 2/3 |
| Cooling | Active Cooling technology |
| Installation location | Indoor and outdoor installation |
| Ambient temperature (°C) | -25 to +60 |
| Permissible humidity (%) | 0 – 100 |
| Noise emission (dB(A)) | < 36 |
| Maximum altitude above sea level (m) | 3,000/4,000 (unrestricted/restricted voltage range) |
| PV installation DC terminals | 3 × DC+ and 3 × DC- push-in spring terminals 2.5 – 10 mm² |
| AC terminals | 5-pin AC push-in spring terminals 1.5 – 10 mm² |
| Backup power terminals | 3-pin backup power push-in spring terminals 1.5–10 mm² |
| PPE clamps | 5 × PPE screw terminals 2.5 – 16 mm² |
| Backup power functions | PV Point (Comfort) |
| DC insulation measurement | Integrated |
| DC disconnector | Integrated |
| Reverse polarity protection | Integrated |
| Arc fault detection | Integrated, Arc Guard Technology |
| WSD emergency shutdown | Integrated |
| WLAN / 2 × Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
| 6 digital inputs | Connection to ripple control receiver, energy management |
| 6 digital inputs/outputs | Connection to ripple control receiver, energy management |
| Data logger and web server | Integrated |
| 2 × RS485 | Modbus RTU SunSpec (third-party provider)/Fronius Smart Meter, battery, Fronius Ohmpilot |
| Certificates and compliance with standards | IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G 98, R25 |
| Country of manufacture | Austria |
| Life cycle analysis | In accordance with ÖNORM EN ISO 14040 and 14044 (checked by employees from Fraunhofer IZM) |
The battery connection applies only to Plus SC; Full Backup is available only in Plus SC 6.0–12.0 and requires external switching components. Battery power and compatibility depend on its type as well as availability and country-specific certification.