Inverter – FRONIUS – Symo GEN24 5.0 Plus SC – hybrid – HV
Incl. VAT
Product details
Symo GEN24 SC
Symo GEN24 SC is a series of photovoltaic inverters with power ratings of 3–12 kW, equipped with the basic PV Point backup power function. Open interfaces enable integration of components from Fronius and other manufacturers, while energy management functions help control system operation. Active cooling extends the inverter’s service life.
Key benefits of Symo GEN24 SC
- PV Point backup power – basic backup power function integrated into the inverter.
- Two maximum power point trackers – the usable MPP voltage range is 80–800 V.
- High efficiency – maximum efficiency is 98.1–98.3%, depending on the model.
- Communication and energy management – WLAN, two Ethernet LAN ports, Fronius Solar.web support, and an integrated data logger and web server.
- Indoor and outdoor installation – IP66 protection rating and an ambient temperature range from −25 to +60 °C.
- Option for future expansion – the Fronius UP.storage software update enables battery support and the Full Backup function on the device.
Who is this a good choice for?
Symo GEN24 SC is an option for photovoltaic system owners who need basic PV Point backup power and access to data and energy management functions. It is also suitable for users planning to postpone their decision on energy storage, thanks to the option to extend its functionality through Fronius UP.storage.
| Parameter | Symo GEN24 5.0 Plus SC |
|---|---|
| Number of MPPT trackers | 2 |
| DC input voltage range (V) | 80 – 1,000 |
| Rated input voltage (V) | 610 |
| Grid feed-in start voltage (V) | 80 |
| Usable MPP voltage range (V) | 80 – 800 |
| MPP voltage range at rated power (V) | 190 – 800 |
| Maximum total usable DC power (W) | 5,200 |
| Maximum total PV generator power (Wp) | 7,500 |
| Maximum usable input current MPPT 1 (A) | 14 |
| Maximum PV generator short-circuit current MPPT 1 (A) | 20 |
| Number of DC connections MPPT 1 | 2 |
| Maximum usable DC power MPPT 1 (W) | 5,200 |
| Maximum PV generator power MPPT 1 (Wp) | 6,500 |
| Maximum usable input current MPPT 2 (A) | 14 |
| Maximum PV generator short-circuit current MPPT 2 (A) | 20 |
| Number of DC MPPT connections 2 | 1 |
| Maximum usable DC power MPPT 2 (W) | 5,200 |
| Maximum PV generator power MPPT 2 (Wp) | 6,500 |
| Rated AC active power (W) | 5,000 |
| Apparent power (VA) | 5,000 |
| Maximum output power (VA) | 5,000 |
| Rated AC output current at 380 V (A) | 7,6 |
| Rated AC output current at 400 V (A) | 7,2 |
| Grid connection (V) | 3~ NPE 400/230 or 3~ NPE 380/220 (+20%/-30%) |
| Rated frequency and frequency range (Hz) | 50/60 (45 – 65) |
| Total harmonic distortion (%) | < 3,5 |
| Power factor cos φ | 0.7 – 1 ind. / cap. |
| PV Point rated output power (VA) | 3,000 |
| PV Point connection (V) | 1~ NPE 220/230 |
| PV Point switchover time (s) | ~15 |
| Number of battery DC inputs | 1 |
| Maximum battery input current (A) | 14 |
| Battery input voltage range (V) | 160 – 700 |
| Battery DC terminals | 1x BATT+ and 1x BATT- push-in spring terminals 2.5 – 10 mm² |
| Maximum battery DC input/output power (W) | 5300 |
| Maximum AC-coupled charging power (W) | 5,000 |
| Compatible batteries | Fronius Reserva & BYD Battery-Box HVS/HVM, HVS+/HVM+ & LG FLEX |
| Maximum efficiency (%) | 98,1 |
| European efficiency (%) | 97,5 |
| MPP tracking efficiency (%) | > 99,9 |
| Nighttime power consumption (W) | <10 |
| Dimensions: height × width × depth (mm) | 530 × 474 × 165 |
| Inverter weight (kg) | 15.3 |
| Degree of protection | IP 66 |
| Protection class | 1 |
| DC/AC overvoltage category | 2/3 |
| Cooling | Active Cooling technology |
| Installation location | Indoor and outdoor installation |
| Ambient temperature (°C) | -25 to +60 |
| Permissible humidity (%) | 0 – 100 |
| Noise emission (dB(A)) | < 36 |
| Maximum altitude above sea level (m) | 3,000/4,000 (unrestricted/restricted voltage range) |
| PV installation DC terminals | 3 × DC+ and 3 × DC- push-in spring terminals 2.5 – 10 mm² |
| AC terminals | 5-pin AC push-in spring terminals 1.5 – 10 mm² |
| Backup power terminals | 3-pin backup power push-in spring terminals 1.5–10 mm² |
| PPE clamps | 5 × PPE screw terminals 2.5 – 16 mm² |
| Backup power functions | PV Point (Comfort) |
| DC insulation measurement | Integrated |
| DC disconnector | Integrated |
| Reverse polarity protection | Integrated |
| Arc fault detection | Integrated, Arc Guard Technology |
| WSD emergency shutdown | Integrated |
| WLAN / 2 × Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
| 6 digital inputs | Connection to ripple control receiver, energy management |
| 6 digital inputs/outputs | Connection to ripple control receiver, energy management |
| Data logger and web server | Integrated |
| 2 × RS485 | Modbus RTU SunSpec (third-party provider)/Fronius Smart Meter, battery, Fronius Ohmpilot |
| Certificates and compliance with standards | IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G 98, R25 |
| Country of manufacture | Austria |
| Life cycle analysis | In accordance with ÖNORM EN ISO 14040 and 14044 (checked by employees from Fraunhofer IZM) |
The battery connection applies only to Plus SC; Full Backup is available only in Plus SC 6.0–12.0 and requires external switching components. Battery power and compatibility depend on its type as well as availability and country-specific certification.