Inverter – FRONIUS – Symo GEN24 8.0 Plus SC – hybrid – HV
Incl. VAT
Product details
GEN24 SC
GEN24 SC by Fronius is a series of three-phase photovoltaic inverters with power ratings of 3–12 kW, equipped with the basic PV Point backup power function. Open interfaces enable the integration of components from Fronius and other suppliers, while energy management functions help control system operation. Integrated active cooling extends the inverter’s service life.
Key advantages of GEN24 SC
- Power 3–12 kW and a maximum efficiency of 98.1–98.3%, depending on the model.
- Built-in PV Point – basic backup power function with a single-phase 220/230 V output and a rated power of 3000 VA.
- Two maximum power point trackers (MPPT), DC input voltage range of 80–1000 V and usable MPP voltage range of 80–800 V.
- Connectivity and integration – WLAN, two Ethernet LAN ports and two RS485 interfaces, plus support for Fronius Solar.web, Modbus TCP SunSpec and Fronius Solar API.
- Protection rating IP66, suitable for indoor and outdoor installation and an ambient temperature range from -25 to +60 °C.
- Integrated protection – arc detection, reverse polarity protection, DC insulation measurement, DC disconnector and WSD emergency shutdown.
Who is this a good choice for?
GEN24 SC is an option for photovoltaic system owners who want basic PV Point backup power and performance monitoring via Fronius Solar.web. It is also suitable for users planning to integrate their system with components from Fronius or other suppliers, thanks to open interfaces and energy management functions.
| Parameter | Symo GEN24 8.0 Plus SC |
|---|---|
| Number of MPPT trackers | 2 |
| DC input voltage range (V) | 80 – 1,000 |
| Rated input voltage (V) | 610 |
| Grid feed-in start voltage (V) | 80 |
| Usable MPP voltage range (V) | 80 – 800 |
| MPP voltage range at rated power (V) | 197 – 800 |
| Maximum total usable DC power (W) | 8,260 |
| Maximum total PV generator power (Wp) | 12,000 |
| Maximum usable input current MPPT 1 (A) | 28 |
| Maximum PV generator short-circuit current MPPT 1 (A) | 40 |
| Number of DC connections MPPT 1 | 2 |
| Maximum usable DC power MPPT 1 (W) | 8,260 |
| Maximum PV generator power MPPT 1 (Wp) | 10,000 |
| Maximum usable input current MPPT 2 (A) | 14 |
| Maximum PV generator short-circuit current MPPT 2 (A) | 20 |
| Number of DC MPPT connections 2 | 1 |
| Maximum usable DC power MPPT 2 (W) | 8,260 |
| Maximum PV generator power MPPT 2 (Wp) | 10,000 |
| Rated AC active power (W) | 8,000 |
| Apparent power (VA) | 8,000 |
| Maximum output power (VA) | 8,000 |
| Rated AC output current at 380 V (A) | 12,1 |
| Rated AC output current at 400 V (A) | 11,6 |
| Grid connection (V) | 3~ NPE 400/230 or 3~ NPE 380/220 (+20%/-30%) |
| Rated frequency and frequency range (Hz) | 50/60 (45 – 65) |
| Total harmonic distortion (%) | < 3,5 |
| Power factor cos φ | 0.7 – 1 ind. / cap. |
| PV Point rated output power (VA) | 3,000 |
| PV Point connection (V) | 1~ NPE 220/230 |
| PV Point switchover time (s) | ~15 |
| Rated Full Backup output power (VA) | 8,000 |
| Rated single-phase Full Backup power (VA) | 4,225 |
| Full Backup connection (V) | 3~ NPE 400/230 or 3~ NPE 380/220 |
| Full Backup switchover time (s) | ~10 |
| Number of battery DC inputs | 1 |
| Maximum battery input current (A) | 22 |
| Battery input voltage range (V) | 160 – 700 |
| Battery DC terminals | 1x BATT+ and 1x BATT- push-in spring terminals 2.5 – 10 mm² |
| Maximum battery DC input/output power (W) | 8260 |
| Maximum AC-coupled charging power (W) | 8,000 |
| Compatible batteries | Fronius Reserva & BYD Battery-Box HVS/HVM, HVS+/HVM+ & LG FLEX |
| Maximum efficiency (%) | 98,3 |
| European efficiency (%) | 98,0 |
| MPP tracking efficiency (%) | > 99,9 |
| Nighttime power consumption (W) | <10 |
| Dimensions: height × width × depth (mm) | 595 × 529 × 180 |
| Inverter weight (kg) | 22.8 |
| Degree of protection | IP 66 |
| Protection class | 1 |
| DC/AC overvoltage category | 2/3 |
| Cooling | Active Cooling technology |
| Installation location | Indoor and outdoor installation |
| Ambient temperature (°C) | -25 to +60 |
| Permissible humidity (%) | 0 – 100 |
| Noise emission (dB(A)) | < 47 |
| Maximum altitude above sea level (m) | 3,000/4,000 (unrestricted/restricted voltage range) |
| PV installation DC terminals | 3 × DC+ and 3 × DC- push-in spring terminals 2.5 – 10 mm² |
| AC terminals | 5-pin AC push-in spring terminals 1.5 – 10 mm² |
| Backup power terminals | 3-pin backup power push-in spring terminals 1.5–10 mm² |
| PPE clamps | 5 × PPE screw terminals 2.5 – 16 mm² |
| Backup power functions | PV Point (Comfort) or Full Backup |
| DC insulation measurement | Integrated |
| DC disconnector | Integrated |
| Reverse polarity protection | Integrated |
| Arc fault detection | Integrated, Arc Guard Technology |
| WSD emergency shutdown | Integrated |
| WLAN / 2 × Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
| 6 digital inputs | Connection to ripple control receiver, energy management |
| 6 digital inputs/outputs | Connection to ripple control receiver, energy management |
| Data logger and web server | Integrated |
| 2 × RS485 | Modbus RTU SunSpec (third-party provider)/Fronius Smart Meter, battery, Fronius Ohmpilot |
| Certificates and compliance with standards | IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G 98, R25 |
| Country of manufacture | Austria |
| Life cycle analysis | In accordance with ÖNORM EN ISO 14040 and 14044 (checked by employees from Fraunhofer IZM) |
The battery connection applies only to Plus SC; Full Backup is available only in Plus SC 6.0–12.0 and requires external switching components. Battery power and compatibility depend on its type as well as availability and country-specific certification.