Fire protection switch – PROJOY – PEFS-EL50H-16 – P2 – 8 strings
| Manufacturer | |
|---|---|
| Weight | 5,48 kg |
| CN | 85353010 |
Gross
Product details
| Manufacturer | |
|---|---|
| Weight | 5,48 kg |
| CN | 85353010 |
Projoy PEFS EL50H-16 Safety Switch – P2
The Projoy PEFS safety switch series is an advanced solution designed to protect photovoltaic systems. It provides physical DC isolation with multiple disconnection methods, including overtemperature protection and emergency shutdown, ensuring high safety and reliability for PV installations.
Key features of the Projoy PEFS safety switch:
- IP66 protection for weather resistance and outdoor installation.
- Construction from flame-retardant materials with anti-UV protection.
- Physical isolation of the OV (Over Voltage) output for maximum safety.
- Multiple disconnection methods: thermal, vacuum-based, and emergency shutdown.
- Long service life of at least 1500 operations under load (PV1).
- Capable of handling 6 to 20 strings depending on the model.
Who is this a good choice for?
The Projoy PEFS safety switch is an ideal choice for PV system installers, solar farm owners, and residential or commercial installations seeking a reliable and safe solution for isolating and protecting their PV systems. High build quality, an IP66 rating, and advanced disconnection features make it well suited for harsh outdoor conditions.
| Parameter | PEFS | |||||||
|---|---|---|---|---|---|---|---|---|
| String voltage (Vdc) | 300-1500 | |||||||
| String current (A) | 9-55 | |||||||
| Number of strings | 6, 8, 10 | |||||||
| Switch cabling | 12, 16, 20 | |||||||
| Operating voltage | 100Vac – 270Vac | |||||||
| Rated voltage | 230Vac | |||||||
| Rated current | 60mA | |||||||
| Inrush current (under load) | average 200mA | |||||||
| Switch-on current | max 600mA | |||||||
| Feedback contact | 24Vdc-600mA max | |||||||
| Operating temperature range | -20°C – +50°C | |||||||
| Max. operating temperature before automatic shutdown | +70°C | |||||||
| Storage temperature range | -40°C – +85°C | |||||||
| Protection rating | IP66 | |||||||
| Protection class | Class II | |||||||
| Certification | CE | |||||||
| DC switch compliant with | EN 60947-1&3 | |||||||
| Number of operations | 10000 | |||||||
| Number of operations under load (PV1) | >1500 | |||||||
| Connector data | ||||||||
| Contact configuration | 1-6, 1-7, 1-8, 1-9, 1-10, 2-10 | |||||||
| Dimensions (mm) | ||||||||
| Height | 405 | |||||||
| Width | 440 | |||||||
| Depth | 422 | |||||||
| 300V | 600V | 800V | 1000V | 1200V | 1500V | Poles | No. of strings | Part number |
| 16 | 16 | 16 | 9 | 6 | 3 | 12/16 | 6/8 | PEFS-EL16-12/16 |
| 25 | 25 | 22 | 11 | 8 | 4 | 12/16 | 6/8 | PEFS-EL25-12/16 |
| 32 | 32 | 26 | 13 | 10 | 5 | 12/16 | 6/8 | PEFS-EL32-12/16 |
| 40 | 40 | 30 | 20 | 10 | 6 | 12/16 | 6/8 | PEFS-EL40-12/16 |
| 55 | 55 | 45 | 25 | 15 | 8 | 12/16 | 6/8 | PEFS-EL55-12/16 |
| 40 | 40 | 40 | 40 | 30 | 20 | 12/16/20 | 6/8/10 | PEFS-EL40H-12/16/20 |