Inverter – DEYE – SUN-20K-SG05LP3-EU – hybrid – LV – OUTLET

SKU: F20GZ33O EAN: 2010000042519
Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

RS485

CAN

RS232

SPD Type II

Off-grid mode

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

Weight 65 kg
CN 85044086
Price 1 704,47 €
Gross

1 704,47 €
Gross

1 704,47 €
Gross

Product details

Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

RS485

CAN

RS232

SPD Type II

Off-grid mode

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

Weight 65 kg
CN 85044086

Three-phase hybrid inverter Deye SUN-14/15/16/18/20K-SG05LP3-EU-SM2

Serviced unit; does not include the original box. All components shown in the photos are included.

The Deye three-phase hybrid inverters from the SUN-K-SG05LP3-EU-SM2 series are advanced, versatile devices designed for large photovoltaic installations in homes and small businesses. They offer high output power (14 to 20 kW) and work with low-voltage (48 V) energy storage systems. With support for parallel operation, diesel generator compatibility, and AC coupling, these inverters provide flexibility, reliability, and efficient energy management.

Key features of the Deye SUN-K-SG05LP3-EU-SM2 inverters:

  • Hybrid versatility: Seamless operation with the grid, PV array, and low-voltage (48 V) lead-acid or lithium-ion batteries.
  • High power and efficiency: Models rated from 14 kW to 20 kW with peak efficiency up to 97.6%.
  • Unbalanced load support: Ability to deliver up to 100% of rated power to a single phase, with maximum output per phase up to 50% of the inverter’s rated power.
  • Flexibility and scalability: AC coupling for retrofitting existing PV systems, support for diesel generator connection, and the ability to run multiple units in parallel (depending on configuration).
  • Advanced energy management: Six programmable battery charge and discharge periods to optimize energy use and costs.
  • High charge/discharge current: Maximum charge/discharge current up to 350 A (depending on model), enabling fast battery energy management.

Who is this a good choice for?

The Deye SUN-K-SG05LP3-EU-SM2 inverters are an excellent choice for owners of larger homes, farms, or small businesses with three-phase power who seek an efficient, flexible hybrid solution. They are ideal for users needing high output power, the ability to support unbalanced loads, emergency power options (including generator support), and preference for safe low-voltage battery systems.

 

Model SUN-14K-SG05LP3-EU-SM2 SUN-15K-SG05LP3-EU-SM2 SUN-16K-SG05LP3-EU-SM2 SUN-18K-SG05LP3-EU-SM2 SUN-20K-SG05LP3-EU-SM2
Battery input data
Battery type Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion
Battery voltage range (V) 40-60 40-60 40-60 40-60 40-60
Max. charging current (A) 260 280 300 330 350
Max. discharging current (A) 260 280 300 330 350
Li-ion battery charging strategy Self-adapts to BMS Self-adapts to BMS Self-adapts to BMS Self-adapts to BMS Self-adapts to BMS
Number of battery ports 1 1 1 1 1
PV input data
Maximum PV access power (W) 28000 30000 32000 36000 40000
Max. PV input power (W) 22400 24000 25600 28800 32000
Max. PV input voltage (V) 800 800 800 800 800
Start voltage (V) 160 160 160 160 160
MPPT voltage range (V) 160-650 160-650 160-650 160-650 160-650
Rated DC input voltage (V) 550 550 550 550 550
Max. PV input current (A) 36+36 36+36 36+36 36+36 36+36
Max. short-circuit current (A) 54+54 54+54 54+54 54+54 54+54
Number of MPP / Number of MPPT strings 2 / 2+2 2 / 2+2 2 / 2+2 2 / 2+2 2 / 2+2
AC input/output data
Rated AC active power (W) 14000 15000 16000 18000 20000
Max. AC apparent power (W) 14000 15000 16000 18000 20000
Rated AC input/output current (A) 21.3/20.3 22.8/21.8 24.3/23.2 27.3/26.1 30.4/29
Max. AC input/output current (A) 23.4/22.4 25/24 26.7/25.6 30/28.7 33.4/31.9
Max. bypass port current Grid->Load (A) 70 70 70 70 70
Peak power (off-grid) (W) 2 times rated power, 10s 2 times rated power, 10s 2 times rated power, 10s 2 times rated power, 10s 2 times rated power, 10s
Power factor 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging
Rated input/output voltage / range (V) 220/380V, 230/400V 0.85Un-1.1Un 220/380V, 230/400V 0.85Un-1.1Un 220/380V, 230/400V 0.85Un-1.1Un 220/380V, 230/400V 0.85Un-1.1Un 220/380V, 230/400V 0.85Un-1.1Un
Rated grid frequency (Hz) 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65
Grid connection 3L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE
Total harmonic current distortion (THDi) <3% (at rated power) <3% (at rated power) <3% (at rated power) <3% (at rated power) <3% (at rated power)
DC injection current <0.5% In <0.5% In <0.5% In <0.5% In <0.5% In
Performance
Max. efficiency 97.6% 97.6% 97.6% 97.6% 97.6%
European efficiency 97.0% 97.0% 97.0% 97.0% 97.0%
MPPT efficiency >99% >99% >99% >99% >99%
Protections
Integrated DC reverse polarity protection, AC output reverse-current protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, protection against surge during load drop, ground fault current monitoring, arc-fault circuit interrupter (optional), power grid monitoring, islanding protection monitoring, earth fault detection, DC input switch, DC terminal insulation impedance monitoring, residual current detection (RCD), surge protection level DC reverse polarity protection, AC output reverse-current protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, protection against surge during load drop, ground fault current monitoring, arc-fault circuit interrupter (optional), power grid monitoring, islanding protection monitoring, earth fault detection, DC input switch, DC terminal insulation impedance monitoring, residual current detection (RCD), surge protection level DC reverse polarity protection, AC output reverse-current protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, protection against surge during load drop, ground fault current monitoring, arc-fault circuit interrupter (optional), power grid monitoring, islanding protection monitoring, earth fault detection, DC input switch, DC terminal insulation impedance monitoring, residual current detection (RCD), surge protection level DC reverse polarity protection, AC output reverse-current protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, protection against surge during load drop, ground fault current monitoring, arc-fault circuit interrupter (optional), power grid monitoring, islanding protection monitoring, earth fault detection, DC input switch, DC terminal insulation impedance monitoring, residual current detection (RCD), surge protection level DC reverse polarity protection, AC output reverse-current protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, protection against surge during load drop, ground fault current monitoring, arc-fault circuit interrupter (optional), power grid monitoring, islanding protection monitoring, earth fault detection, DC input switch, DC terminal insulation impedance monitoring, residual current detection (RCD), surge protection level
Surge protection level TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC)
Communication
Communication interface RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN
Monitoring modes GPRS/WIFI/Bluetooth/4G/LAN(optional) GPRS/WIFI/Bluetooth/4G/LAN(optional) GPRS/WIFI/Bluetooth/4G/LAN(optional) GPRS/WIFI/Bluetooth/4G/LAN(optional) GPRS/WIFI/Bluetooth/4G/LAN(optional)
General data
Operating temperature (°C) -40 to +60°C, >45°C derating -40 to +60°C, >45°C derating -40 to +60°C, >45°C derating -40 to +60°C, >45°C derating -40 to +60°C, >45°C derating
Permissible ambient humidity 0-100% 0-100% 0-100% 0-100% 0-100%
Max. installation altitude 3000m 3000m 3000m 3000m 3000m
Noise level (dB) ≤55 dB(A) ≤55 dB(A) ≤55 dB(A) ≤55 dB(A) ≤55 dB(A)
Ingress protection rating IP 65 IP 65 IP 65 IP 65 IP 65
Inverter topology Transformerless Transformerless Transformerless Transformerless Transformerless
Overvoltage category OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC)
Cabinet size (W × H × D mm) 456×750×268.5 (Without connectors and mounting brackets) 456×750×268.5 (Without connectors and mounting brackets) 456×750×268.5 (Without connectors and mounting brackets) 456×750×268.5 (Without connectors and mounting brackets) 456×750×268.5 (Without connectors and mounting brackets)
Weight (kg) 50.6 50.6 50.6 50.6 50.6
Cooling type Intelligent air cooling Intelligent air cooling Intelligent air cooling Intelligent air cooling Intelligent air cooling
Warranty 5-year / 10-year warranty period

Depends on inverter installation conditions. Details are available in the general warranty terms.

5-year / 10-year warranty period

Depends on inverter installation conditions. Details are available in the general warranty terms.

5-year / 10-year warranty period

Depends on inverter installation conditions. Details are available in the general warranty terms.

5-year / 10-year warranty period

Depends on inverter installation conditions. Details are available in the general warranty terms.

5-year / 10-year warranty period

Depends on inverter installation conditions. Details are available in the general warranty terms.

Grid connection standards IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
EMC / Safety standards IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Official distribution