Inverter – GOODWE – GW60KS-MT-EU_AFCI
Product details
SMT
SMT by GoodWe is a series of three-phase string inverters designed for commercial rooftop photovoltaic installations with complex configurations. The rated output power is 25–60 kW, with 3–6 MPPTs, depending on the model. The compact and lightweight design facilitates transport and installation.
Key advantages of SMT
- Flexible system configuration: 3–6 MPPTs, two photovoltaic module strings per MPPT, depending on the model.
- High efficiency: maximum efficiency is 98.6–98.8%, and European efficiency is 98.1–98.5%, depending on the model.
- Full power up to 45°C: operation at full power at temperatures up to 45°C.
- Surge protection: type II protection on the AC and DC sides.
- Integrated monitoring: PV string current measurement, PV insulation resistance detection and residual current monitoring.
- Integration with the GoodWe SEC1000 controller: ability to monitor loads and limit energy exports.
Who is this a good choice for?
The SMT series is designed for businesses using commercial photovoltaic systems on roofs with complex structures. A power range of 25–60 kW and 3–6 MPPTs allow the model to be matched to the system configuration, while integration with GoodWe SEC1000 meets the need for load monitoring and limiting energy exports.
| Parameter | GW25K-MT | GW30K-MT | GW36K-MT | GW50KS-MT | GW60KS-MT | GW50KS-MT-EU | GW60KS-MT-EU |
|---|---|---|---|---|---|---|---|
| DC input data | |||||||
| Maximum input voltage (V) | 1100 | ||||||
| MPPT operating voltage range (V) | 200 ~ 950 | ||||||
| Start-up voltage (V) | 180 | ||||||
| Rated input voltage (V) | 600 | ||||||
| Maximum input current per MPPT (A) | 30 | ||||||
| Maximum short-circuit current per MPPT (A) | 37,5 | ||||||
| Number of MPPTs | 3 | 5 | 6 | 5 | 6 | ||
| Number of photovoltaic module strings per MPPT | 2 | ||||||
| AC output data | |||||||
| Rated output power (kW) | 25,0 | 30,0 | 36,0 | 50,0 | 60,0 | 50,0 | 60,0 |
| Rated output apparent power (kVA) | 25,0 | 30,0 | 36,0 | 50,0 | 60,0 | 50,0 | 60,0 |
| Maximum AC active power (kW) | 27,5 | 33,0 | 36,0 | 55,0 | 66,0 | 55,0 | 66,0 |
| Maximum AC apparent power (kVA) | 27,5 | 33,0 | 36,0 | 55,0 | 66,0 | 55,0 | 66,0 |
| Rated output voltage (V) | 400, 3L / N / PE or 3L / PE | 230 / 400, 3L / N / PE or 3L / PE | |||||
| Output voltage range (V) | 320 ~ 460 | ||||||
| Rated AC grid frequency (Hz) | 50 / 60 | ||||||
| AC grid frequency range (Hz) | 47,5 ~ 51,5 / 57,0 ~ 61,8 | 45 ~ 55 / 55 ~ 65 | |||||
| Maximum output current (A) | 40,0 | 48,0 | 53,3 | 80,0 | 96,0 | 80 | 96 |
| Power factor adjustment range | ~1 (adjustable from 0.8 leading to 0.8 lagging) | ||||||
| Total harmonic distortion THD (%) | <3% | ||||||
| Efficiency | |||||||
| Maximum efficiency (%) | 98,7 | 98,8 | 98,6 | ||||
| European efficiency (%) | 98,4% | 98,5% | 98,1% | ||||
| Protection | |||||||
| PV string current monitoring | Integrated. | ||||||
| PV insulation resistance detection | Integrated. | ||||||
| Residual current monitoring | Integrated. | ||||||
| Reverse polarity protection in the DC circuit | Integrated. | ||||||
*The basket impedance has been set in accordance with EN50549-1, C10/11, VDE-AR-N 4105, NTS type A, CEI 0-21: 2019, G98, G99, UTE C15-712-1, VDE 0126-1-1, VFR2019, PPDES 2022, UNE 217001: 2020, EN50549-2, C10/11, VDE-AR-N 4105, NTS type B, CEI 0-21: 2019, G98, G99, UTE C15-712-1, VDE 0126-1-1, VFR2019, PPDES 2022, UNE 217001: 2020. **Values and certificates are available on the GoodWe website.