Inverter – GOODWE – GW50K-ET-10 – hybrid – HV
Product details
ET50
GoodWe’s ET50 is a series of three-phase hybrid inverters for commercial and industrial energy storage systems. Intelligent operating modes support self-consumption, peak shaving, time-of-use tariffs, and grid support. Parallel connection capability allows the expansion of on-grid and off-grid installations.
Key benefits of ET50
- Rated output power of 40–50 kW and 3–4 MPPT systems — depending on the model; the MPPT operating voltage range is 165–850 V.
- Compatibility with lithium-ion batteries with a voltage of 200–800 V and a maximum continuous charging and discharging current of 100 A.
- Maximum efficiency 98.1% and European efficiency of 97.5%.
- Backup power with UPS-level switching — this function requires an additional STS box.
- Parallel connection enabling system expansion in both grid-connected and off-grid installations.
- IP66 protection rating and integrated safeguards, including AC and DC overcurrent protection, DC reverse polarity protection, and type II surge arresters on the AC and DC sides.
Who is this a good choice for?
ET50 is designed for businesses and industrial facilities looking to increase energy self-consumption, reduce peak power demand and take advantage of time-of-use tariffs. It is also a solution for businesses planning to expand energy storage through parallel connection or requiring backup power with the addition of an STS box.
| Parameter | GW40K-ET-10 | GW50K-ET-10 |
|---|---|---|
| Battery input data | ||
| Battery type | Li-Ion | |
| Nominal battery voltage (V) | 500 | |
| Battery voltage range (V) | 200 ~ 800 | |
| Start-up voltage (V) | 200 | |
| Number of battery inputs | 1 | |
| Maximum continuous charging current (A) | 100 | |
| Maximum continuous discharge current (A) | 100 | |
| DC input data | ||
| Maximum input power (W) | 60000 | 75000 |
| Maximum input voltage (V) | 1000 | |
| MPPT operating voltage range (V) | 165 ~ 850 | |
| Start-up voltage (V) | 200 | |
| Rated input voltage (V) | 620 | |
| Maximum input current per MPPT (A) | 42 / 32 / 42 | 42 / 32 / 32 |
| Maximum short-circuit current per MPPT (A) | 55 / 42 / 55 | 55 / 42 / 42 |
| Number of MPPTs | 3 | 4 |
| Number of photovoltaic module strings per MPPT | 2 | |
| AC output data (grid-connected operation) | ||
| Rated output power (W) | 40000 | 50000 |
| Rated apparent power fed into the grid (VA) | 40000 | 50000 |
| Maximum apparent power fed into the grid (VA) | 40000 | 50000 |
| Maximum output power (VA) | 40000 | 50000 |
| Rated output voltage (V) | 380 / 400, 3L / N / PE | |
| Output voltage range (V) | 176 ~ 276 | |
| Rated AC grid frequency (Hz) | 50 / 60 | |
| AC grid frequency range (Hz) | 45 ~ 55 / 55 ~ 65 | |
| Maximum AC current from the power grid (A) | 60.6 @ 380V; 58.0 @ 400V | 75.8 @ 380V; 72.5 @ 400V |
| Power factor adjustment range | ~1 (adjustable from 0.8 leading to 0.8 lagging) | |
| Total harmonic distortion THD (%) | <3 | |
| AC output data (backup circuit) | ||
| Rated backup apparent power (VA) | 40000 | 50000 |
| Maximum apparent power (VA) | 44000 (48000 @ 60 sec., 60000 @ 10 sec.) | 55000 (60000 @ 60 sec., 75000 @ 10 sec.) |
| Maximum output current (A) | 66.7 @ 380V; 63.8 @ 400V | 83.3 @ 380V; 79.7 @ 400V |
| Rated output voltage (V) | 380 / 400, 3L / N / PE | |
| Rated output frequency (Hz) | 50 / 60 | |
| Output THDv distortion under linear load (%) | <3 | |
| Efficiency | ||
| Maximum efficiency (%) | 98,1 | |
| European efficiency (%) | 97,5 | |
| Maximum battery efficiency under load (%) | 97,7 | |
| MPPT efficiency (%) | 99,0 | |
| Protection | ||
| Residual current monitoring | Integrated. | |
| Reverse polarity protection in the DC circuit | Integrated. | |
| Reverse polarity protection in the energy storage power supply circuit | Integrated. | |
| Anti-islanding protection | Integrated. | |
| AC circuit overcurrent protection | Integrated. | |
| DC circuit overcurrent protection | Integrated. | |
| AC circuit short-circuit protection | Integrated. | |
| AC circuit surge protection | Type II (Type I + II Optional) | |
| DC circuit surge protection | Type II | |
| DC switch disconnector | Integrated. | |
| DC circuit surge arrester | Type II | |
| Surge arrester in the AC circuit | Type II | |
| AFCI arc fault protection | Optionally | |
| Remote shutdown | Integrated. | |
| Operating conditions | ||
| Operating temperature range (°C) | -35 ~ +60 | |
| Relative humidity (%) | 0 ~ 95 | |
| Maximum operating altitude above sea level (m) | 4000 | |
| Cooling method | Intelligent active cooling | |
| IP protection rating | IP66 | |
| Communication and operation | ||
| Display | LED, WLAN + APP | |
| Communication with BMS | CAN | |
| Communication with the meter | RS485 | |
| Communication with the portal | RS485, WiFi + LAN + Bluetooth, 4G + Bluetooth (Optional) | |
| Dimensions and weight | ||
| Weight (kg) | 62 | 65 |
| Dimensions (W × H × D) (mm) | 520 × 660 × 260 | |
| Installation method | Wall mounting | |
| General information | ||
| Topology | Uninsulated | |
| Nighttime power consumption (W) | <15 | |
| Compatibility with the BAT61.4 energy storage system | ||
| Battery type | Li-Ion | |
| Number of connected storage units (pcs.) | 1 / 2 / 3 / 4 | |
| Inverter AC power (kW) | 40 | 50 |
| Maximum inverter battery current (A) | 100 | |
| Nominal capacity of a single storage unit (kWh) | 61,4 | |
| Usable capacity per battery (kWh) | 60 | |
| Nominal storage voltage (V) | 307,2 | |
| Power limited by inverter current (kW) | 30,72 | |
| Maximum energy storage charging power (kW) | 30,72 | |
| Maximum storage discharge power (kW) | 30,72 | |
| Compatibility with the BAT112.6 energy storage system | ||
| Battery type | Li-Ion | |
| Number of connected storage units (pcs.) | 1 / 2 / 3 / 4 | |
| Inverter AC power (kW) | 40 | 50 |
| Maximum inverter battery current (A) | 100 | |
| Nominal capacity of a single storage unit (kWh) | 112,6 | |
| Usable capacity per battery (kWh) | 110 | |
| Nominal storage voltage (V) | 563,2 | |
| Power limited by inverter current (kW) | 56,32 | |
| Maximum energy storage charging power (kW) | 40 | 50 |
| Maximum storage discharge power (kW) | 40 | 50 |
The backup circuit requires an additional STS box. The output voltage range refers to the phase voltage. At input voltages above 980 V, the inverter enters standby mode and resumes operation below 970 V. For most PV modules, the maximum input power can reach 2 × Pn. The MPPT counts and current values per MPPT have been retained as listed in the source table.