P3-S is a series of Fox ESS three-phase hybrid inverters with a nominal output power of 5–15 kW, compatible with high-voltage LFP batteries. It allows solar energy to be used during the day and stored for the night. Remote monitoring via a mobile app or website enables device operation to be monitored in the FoxCloud V2.0 system.

Key benefits of P3-S

  • Output power 5–15 kW and 2–3 independent MPPT circuits, depending on the model.
  • Compatibility with LFP batteries within a voltage range of 100–800 V, with a maximum charging and discharging current of 50 A and charging and discharging power of up to 15 kW.
  • EPS output with a switchover time of less than 20 ms and a maximum apparent power of 5000–15000 VA, depending on the model.
  • Protection rating IP65 permitting outdoor use and wall mounting.
  • Electrical protection including short-circuit, overcurrent, overtemperature and Type II surge protection on the PV and AC sides; AFCI protection is optional.
  • Standard 10-year warranty and easy configuration and plug-and-play installation.

Who is this a good choice for?

P3-S is designed for photovoltaic system users who want to combine immediate use of solar energy with storage in high-voltage Fox ESS batteries. It is also an option for those who need an EPS output and remote monitoring of system operation. The 5–15 kW power range allows users to select a version that meets the system’s required power rating.

ParameterP3-5.0-SHP3-6.0-SHP3-8.0-SHP3-10.0-SHP3-12.0-SHP3-15.0-SH
DC input data
Maximum PV power (Wp)110001400018000200002400030000
Maximum input power (W)1100013200176001800022500
Maximum input voltage (V)1000 [1]
Nominal input voltage (V)620
Maximum MPPT input current (A)20/20
Maximum MPPT short-circuit current (A)25/25
Maximum MPPT input power (W)10000/10000
Minimum PV operating voltage (V)90 [2]
MPPT operating voltage range (V)120 ~ 950
Start-up voltage (V)140
Number of independent MPPTs23
Number of strings per MPPT1+11+1+1
Batteries
Battery typeLithium-ion (LFP)
Battery voltage range (V)100 ~ 800
Minimum battery operating voltage (V)100
Minimum battery voltage at full AC load (V)108125160210250310
Maximum charging/discharging current (A)50
Battery communication interfaceCAN
AC output data
Nominal output power (W)500060008000100001200015000
Maximum apparent power (VA)55006600880011000 [3]1320016500
Nominal grid voltage (V)400/230 AC; 380/220 AC, 3L/N/PE
Rated grid frequency (Hz)50/60, ±5
Rated AC current per phase (A)7,69,112,115,218,222,7
Maximum AC current per phase (A)8,310,013,316,720,025,0
Power factor1 (adjustable from 0.8 capacitive to 0.8 inductive)
Current total harmonic distortion THDI (%)<3 at nominal power
AC input data
Maximum AC input power (VA)600072009600120001440016000
Nominal AC grid voltage (V)400/230 AC; 380/220 AC, 3L/N/PE
Nominal AC grid frequency (Hz)50/60, ±5
Maximum AC current per phase (A)9,110,914,518,221,824,2
EPS output data
Maximum apparent power (VA)500060008000100001200015000
Peak apparent power for 60 s (VA)600072009600120001440015000
Nominal EPS grid voltage (V)400/230 AC; 380/220 AC, 3L/N/PE
Nominal EPS grid frequency (Hz)50/60
Maximum EPS current per phase (A)7,28,711,614,517,421,7
Power factor1 (adjustable from 0.8 capacitive to 0.8 inductive)
Switching time (ms)<20
Voltage harmonic distortion THDV (%)<3 under linear load
Efficiency
MPPT efficiency (%)97,3097,7097,90
Maximum efficiency (%)99,90
European efficiency (%)97,20
Protection
PV reverse polarity protectionYes
Battery reverse polarity protectionYes
Anti-islanding protectionYes
Short-circuit protectionYes
Leakage current monitoringYes
Insulation resistance monitoringYes
Overvoltage categoryIII (AC side), II (DC side)
Reverse polarity protectionYes
Overcurrent / thermal protectionYes
AC/DC surge protectionType II(PV)/Type II(AC)
AFCI protectionOptional
DC disconnectorYES
Dimensions and weight
Dimensions (W × H × D) (mm)600*450*226
Net weight (kg)34
Operating conditions
InstallationWall-mounted
Operating temperature range (°C)-25 ~ +60 (derating at 45)
Storage temperature (°C)-40 ~ +70
Storage/operating relative humidity (%)0 ~ 100
Working height (m)<4000 (derating above 2000)
Protection classAND
Degree of protectionIP65 (for outdoor use)
Power consumption (W)20 ~ 25
Idle modeYes
CoolingNaturalFan cooling
Noise level (dB)<40<55
General data and communication
Inverter topologyTransformerless
CommunicationEthernet, EMS(RS485), meter, WLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready
Buttons4 capacitive touch buttons
Audible alarm1, Internal (EPS and ground fault)
Warranty
Product warranty (years)10

[1] For a 1000 V system, the maximum PV operating voltage is 950 V. [2] The inverter startup voltage is 90 V. [3] In Belgium, the apparent power of the 10000 W model is limited to 10000 VA.