Inverter – FoxESS – P3-12.0-SH – hybrid – HV
Product details
P3-S
P3-S is a series of Fox ESS three-phase hybrid inverters compatible with high-voltage LFP lithium-ion batteries. They enable the use of solar energy during the day and its storage for the night. Plug-and-play configuration and installation simplify commissioning, while FoxCloud V2.0 allows remote monitoring of device operation via a mobile app or website.
Key benefits of P3-S
- Nominal output power 5–15 kW and 2–3 independent MPPT circuits, depending on the model.
- Compatibility with LFP batteries with a voltage of 100–800 V and a maximum charging and discharging current of 50 A.
- EPS output with a switchover time of less than 20 ms and a maximum apparent power of 5000–15000 VA, depending on the model.
- Protection rating IP65 allowing outdoor use and wall mounting.
- Short-circuit, overcurrent and thermal protection and type II surge protection on the PV and AC sides.
- Standard 10-year warranty for the entire series.
Who is this a good choice for?
P3-S is an option for homeowners and businesses that want to use solar energy and store it in batteries for nighttime use. The power range allows users to choose a model that matches the required system capacity, while remote monitoring makes it easier to track system operation.
| Parameter | P3-5.0-SH | P3-6.0-SH | P3-8.0-SH | P3-10.0-SH | P3-12.0-SH | P3-15.0-SH |
|---|---|---|---|---|---|---|
| DC input data | ||||||
| Maximum PV power (Wp) | 11000 | 14000 | 18000 | 20000 | 24000 | 30000 |
| Maximum input power (W) | 11000 | 13200 | 17600 | 18000 | 22500 | |
| Maximum input voltage (V) | 1000 | |||||
| Nominal input voltage (V) | 620 | |||||
| Maximum MPPT input current (A) | 20/20 | |||||
| Maximum MPPT short-circuit current (A) | 25/25 | |||||
| Maximum MPPT input power (W) | 10000/10000 | |||||
| Minimum PV operating voltage (V) | 90 | |||||
| MPPT operating voltage range (V) | 120 ~ 950 | |||||
| Start-up voltage (V) | 140 | |||||
| Number of independent MPPTs | 2 | 3 | ||||
| Number of strings per MPPT | 1+1 | 1+1+1 | ||||
| Batteries | ||||||
| Battery type | Lithium-ion (LFP) | |||||
| Battery voltage range (V) | 100 ~ 800 | |||||
| Minimum battery operating voltage (V) | 100 | |||||
| Minimum battery voltage at full AC load (V) | 108 | 125 | 160 | 210 | 250 | 310 |
| Maximum charging/discharging current (A) | 50 | |||||
| Communication interface | CAN | |||||
| AC output data | ||||||
| Nominal output power (W) | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 |
| Maximum apparent power (VA) | 5500 | 6600 | 8800 | 11000 | 13200 | 16500 |
| Nominal grid voltage (V) | 400/230 AC; 380/220 AC, 3L/N/PE | |||||
| Rated grid frequency (Hz) | 50/60, ±5 | |||||
| Rated AC current per phase (A) | 7,6 | 9,1 | 12,1 | 15,2 | 18,2 | 22,7 |
| Maximum AC current per phase (A) | 8,3 | 10,0 | 13,3 | 16,7 | 20,0 | 25,0 |
| Power factor | 1 (adjustable from 0.8 capacitive to 0.8 inductive) | |||||
| THDI (%) | <3 at nominal power | |||||
| AC input data | ||||||
| Maximum AC input power (VA) | 6000 | 7200 | 9600 | 12000 | 14400 | 16000 |
| Nominal AC grid voltage (V) | 400/230 AC; 380/220 AC, 3L/N/PE | |||||
| Nominal AC grid frequency (Hz) | 50/60, ±5 | |||||
| Maximum AC current per phase (A) | 9,1 | 10,9 | 14,5 | 18,2 | 21,8 | 24,2 |
| EPS output data | ||||||
| Maximum apparent power (VA) | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 |
| Peak apparent power for 60 s (VA) | 6000 | 7200 | 9600 | 12000 | 14400 | 15000 |
| Nominal EPS grid voltage (V) | 400/230 AC; 380/220 AC, 3L/N/PE | |||||
| Nominal EPS grid frequency (Hz) | 50/60 | |||||
| Maximum EPS current per phase (A) | 7,2 | 8,7 | 11,6 | 14,5 | 17,4 | 21,7 |
| Power factor | 1 (adjustable from 0.8 capacitive to 0.8 inductive) | |||||
| Switching time (ms) | <20 | |||||
| THDV (%) | <3 under linear load | |||||
| Efficiency | ||||||
| MPPT efficiency (%) | 97,30 | 97,70 | 97,90 | |||
| Maximum efficiency (%) | 99,90 | |||||
| European efficiency (%) | 97,20 | |||||
| Protection | ||||||
| PV reverse polarity protection | YES | |||||
| Battery reverse polarity protection | YES | |||||
| Anti-islanding protection | YES | |||||
| Short-circuit protection | YES | |||||
| Leakage current monitoring | YES | |||||
| Insulation resistance monitoring | YES | |||||
| Overvoltage category | III (AC side), II (DC side) | |||||
| Reverse polarity protection | YES | |||||
| Overcurrent and overtemperature protection | YES | |||||
| AC/DC surge protection | Type II (PV)/Type II (AC) | |||||
| AFCI protection | Optional | |||||
| DC disconnector | YES | |||||
| Dimensions and weight | ||||||
| Dimensions (W × H × D) (mm) | 600*450*226 | |||||
| Net weight (kg) | 34 | |||||
| Operating conditions | ||||||
| Mounting method | Wall mounting | |||||
| Operating temperature range (°C) | -25 ~ +60 (derating at 45) | |||||
| Storage temperature (°C) | -40 ~ +70 | |||||
| Storage and operating relative humidity (%) | 0 ~ 100 | |||||
| Working height (m) | <4000; derating above 2000 | |||||
| Protection class | AND | |||||
| Degree of protection | IP65 (for outdoor use) | |||||
| Power consumption (W) | 20 ~ 25 | |||||
| Idle mode | YES | |||||
| Cooling | Natural | Fan cooling | ||||
| Noise level (dB) | <40 | <55 | ||||
| General data and communication | ||||||
| Inverter topology | Transformerless | |||||
| Communication | Ethernet, EMS (RS485), meter, WLAN (WiFi+LAN+Bluetooth), 4G (optional), DRM, ripple control, USB, BMS (CAN), SG Ready | Ethernet, EMS(RS485), meter, WLAN(Wifi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS (RS485), meter, WLAN (WiFi+LAN+Bluetooth), 4G (optional), DRM, ripple control, USB, BMS (CAN), SG Ready | |||
| Buttons | 4 capacitive touch buttons | |||||
| Audible alarm | 1, internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, internal (EPS and ground fault) | |||
| Warranty | ||||||
| Product warranty (years) | 10 | |||||
For a 1000 V system, the maximum PV operating voltage is 950 V. The inverter start-up voltage is 90 V. In Belgium, the apparent power of the 10000 W model is limited to 10000 VA.