Inverter – FRONIUS – Verto 17.5 Plus – hybrid – HV

SKU: 4,210,452
Manufacturer

Net depth

Weight 43 kg
Price 4 154,14 €
Incl. VAT

4 154,14 €
Incl. VAT

4 154,14 €
Incl. VAT

Product details

Manufacturer

Net depth

Weight 43 kg

Verto Plus 17.5

Verto Plus 17.5 is a three-phase, transformerless photovoltaic inverter with a rated power of 17.5 kW, equipped with a DC battery input. Three MPPT controllers support a photovoltaic array with a maximum total power of 26.25 kWp. The device also offers a full backup power mode (Full Backup) and a fast switching mode with a switching time of less than 20 ms.

Key benefits of Verto Plus 17.5

  • Rated power 17.5 kW and a three-phase grid connection.
  • Three MPPT controllers with an MPP voltage range of 210–870 VDC and support for a PV array with a maximum total power of 26.25 kWp.
  • Battery DC input with a voltage of 150–700 V, a maximum current of 50 A and a maximum power of 26.25 kW.
  • Full backup power supply (Full Backup) with a rated output power of 17.5 kW; the AC-Boost function delivers 30 kVA for 5–10 s.
  • Fast switching in under 20 ms in fast switching mode; the standard switching time is less than 35 s.
  • IP66 protection rating and permissible ambient temperature from −40 to +60°C.

Who is this a good choice for?

Verto Plus 17.5 is an option for photovoltaic system owners who need a 17.5 kW three-phase inverter with three MPPT trackers. It offers a dedicated DC input for users planning to connect a battery, and a Full Backup mode with AC-Boost and fast switching capability for those seeking backup power.

ParameterValue
DC input data
Maximum input voltage at 1000 W/m² and -10°C under open-circuit conditions (VDC)1000
Start-up voltage (VDC)150
MPP voltage range (VDC)210–870
Number of MPPT controllers3
Maximum input current PV1 / PV2 / PV3 (A)28 / 28 / 28
Maximum input current per string (A)28
Maximum total short-circuit current (A)150
Maximum short-circuit current PV1 / PV2 / PV3 (A)50 / 50 / 50
Maximum short-circuit current per string (A)50
Maximum total PV array power (kWp)26,25
Maximum PV array power for PV1 / PV2 / PV3 (kWp)20 / 20 / 20
DC overvoltage category2
Maximum inverter reverse current (A)0
Maximum photovoltaic generator capacitance to ground (nF)3600
Insulation and residual current monitoring
Factory-set limit for insulation resistance monitoring between the photovoltaic generator and earth (kΩ)34
Setting range for insulation resistance monitoring between the photovoltaic generator and ground (kΩ)34–10 000
Factory-set threshold and detection time for sudden residual current (mA / ms)30 / 300; 60 / 150; 90 / 40
Factory-set limit value and detection time for continuous residual current (mA / ms)300 / 300
Continuous residual current detection setting range (mA)30-1000
Factory-set interval for periodic insulation resistance checks (h)24
Setting range for repeated cyclic insulation resistance checks-
Battery DC input data
Maximum voltage (V)700
Minimum voltage (V)150
Maximum current (A)50
Maximum power (kW)26,25
Number of DC inputs1
AC output data
Grid voltage range (VAC)176–528
Rated mains voltage (VAC)3~ (N)PE 380 / 220, 3~ (N)PE 400 / 230, 3~ (N)PE 440 / 253, 3~ (N)PE 480 / 277
Rated power (kW)17,5
Maximum usable inverter DC power (kW)26,25
Rated apparent power (kVA)17,5
Rated frequency (Hz)50/60
Maximum output current per phase (A)32,3
Initial short-circuit alternating current per phase (A)32,3
Power factor cos φ0–1 individuals/container
Grid connection (VAC)3~ (N)PE 380 / 220, 3~ (N)PE 400 / 230, 3~ (N)PE 440 / 253, 3~ (N)PE 480 / 277
Earthing systemsTT (permitted if UN_PE <30 V), TN-S (permitted), TN-C-S (permitted), IT (not permitted)
Maximum output power (kW)17,5
Rated output current per phase (A)26,5 / 25,4 / 23,0 / 21,1
Total harmonic distortion (%)<3
AC overvoltage category3
Peak inrush current (A)24,72
RMS inrush current (A)6,82
Inrush current duration (ms)1,99
Maximum output short-circuit current and its duration (A / ms)24,38 / 38,72
AC output data in full backup power mode
Maximum output current per phase during three-phase operation (A)32,3
Maximum output current per phase during three-phase operation with AC-Boost (A)43.5 (for 5–10 s)
Maximum output current during single-phase operation with AC-Boost (A)32 (for 5–10 s)
Rated output power (kW)17,5
Apparent power with AC-Boost (kVA)30 (for 5–10 s)
Rated output current per phase (A)32.3 (max. asymmetry 25 A)
Rated mains voltage (VAC)3~ (N)PE 380 / 220, 3~ (N)PE 400 / 230, 3~ (N)PE 440 / 253, 3~ (N)PE 480 / 277
Rated frequency (Hz)53/63
Switching time (s)<35
Switching time in fast switching mode (ms)<20
Power factor cos φ0–1 individuals/container
Efficiency and losses
Nighttime standby losses (W)16
European efficiency at 210 / 600 / 870 VDC (%)96,87 / 97,54 / 96,88
Maximum efficiency (%)97,42
Operating conditions and protection
Protection class1
Device EMC emission classB
Pollution degree3
Permissible ambient temperature (°C)-40 – +60
Permissible storage temperature (°C)-40 – +70
Relative humidity (%)0-100
Sound pressure level (dB(A))50.3 (ref. 20 µPA)
Degree of protectionIP66
Dimensions and weight
Dimensions: height × width × depth (mm)865 × 574 × 279
Inverter weight (kg)40,1
General information
Inverter topologynon-isolated, transformerless

Official distribution