Inverter – FRONIUS – Verto 20.0 Plus – hybrid – HV

SKU: 4,210,454
Manufacturer

Net depth

Weight 43 kg
Price 4 424,19 €
Incl. VAT

4 424,19 €
Incl. VAT

4 424,19 €
Incl. VAT

Product details

Manufacturer

Net depth

Weight 43 kg

Verto Plus 20.0

Verto Plus 20.0 is a Fronius three-phase photovoltaic inverter with a rated output of 20 kW, equipped with a DC battery input. The transformerless design offers three MPPT controllers and supports a photovoltaic array with a total capacity of up to 30 kWp. Full backup power mode enables operation at a rated output of 20 kW, while fast switching mode provides a switchover time of less than 20 ms.

Key benefits of Verto Plus 20.0

  • Rated power 20 kW and a three-phase grid connection.
  • Three MPPT controllers with an MPP voltage range of 240–870 VDC and a maximum total PV array power of 30 kWp.
  • Battery DC input with a voltage range of 150–700 V, a maximum current of 50 A and a maximum power of 30 kW.
  • Full backup power with a rated power of 20 kW and a temporary power boost function up to 30 kVA for 5–10 s.
  • Fast switching in under 20 ms in fast switching mode; the standard switching time is less than 35 s.
  • IP66 protection rating and permissible ambient temperature from −40°C to +60°C.

Who is this a good choice for?

This solution is for owners of photovoltaic systems who need a 20 kW three-phase inverter with battery connectivity. It is also suitable for users who require full backup power and a switchover time of less than 20 ms in fast switching mode.

ParameterValue
DC input data
Maximum input voltage at 1000 W/m² and -10°C under open-circuit conditions (VDC)1000
Start-up voltage (VDC)150
MPP voltage range (VDC)240–870
Number of MPPT controllers3
Maximum input current PV1 / PV2 / PV3 (A)28 / 28 / 28
Maximum input current per string (A)28
Maximum total short-circuit current (A)150
Maximum short-circuit current PV1 / PV2 / PV3 (A)50 / 50 / 50
Maximum short-circuit current per string (A)50
Maximum total PV array power (kWp)30,0
Maximum PV array power for PV1 / PV2 / PV3 (kWp)20 / 20 / 20
DC overvoltage category2
Maximum inverter reverse current (A)0
Maximum photovoltaic generator capacitance to ground (nF)5000
Factory-set threshold for monitoring insulation resistance between the generator and ground (kΩ)34
Setting range for insulation resistance monitoring between the generator and ground (kΩ)34–10 000
Factory-set threshold and detection time for sudden residual current (mA / ms)30 / 300; 60 / 150; 90 / 40
Factory-set limit value and detection time for continuous residual current (mA / ms)300 / 300
Continuous residual current detection setting range (mA)30-1000
Factory-set interval for periodic insulation resistance checks (h)24
Setting range for the periodic insulation resistance test interval-
Battery DC input data
Maximum voltage (V)700
Minimum voltage (V)150
Maximum current (A)50
Maximum power (kW)30
Number of DC inputs1
AC output data
Grid voltage range (VAC)176–528
Rated mains voltage (VAC)220 / 230; 253 / 257
Rated power (kW)20
Maximum usable inverter DC power (kW)30
Rated apparent power (kVA)20
Rated frequency (Hz)50/60
Maximum output current per phase (A)32,3
Initial symmetrical short-circuit current per phase IK″ (A)32,3
Power factor cos φ0–1 individuals/container
Grid connection (VAC)3~ (N)PE 380 / 220; 3~ (N)PE 400 / 230; 3~ (N)PE 440 / 253; 3~ (N)PE 480 / 277
Earthing systemsTT (permitted if UN_PE <30 V); TN-S(permitted); TN-C-S(permitted); IT(not permitted)
Maximum output power (kW)20
Rated output current per phase (A)30,3 / 29 / 26,2 / 24,1
Total harmonic distortion (%)<3
AC overvoltage category3
Peak inrush current (A)24,72
RMS inrush current (A)6,82
Inrush current duration (ms)1,99
Maximum output short-circuit current and duration (A / ms)24,38 / 38,72
AC output data in full backup power mode (Full Backup)
Maximum output current per phase (A)32,3
Maximum output current per phase with 3 phases and AC-Boost (A)43.5 (for 5–10 s)
Maximum single-phase output current with AC-Boost (A)32 (for 5–10 s)
Rated output power (kW)20
Apparent output power with AC-Boost (kVA)30 (for 5–10 s)
Rated output current per phase (A)32,3
Maximum current asymmetry (A)25
Rated mains voltage (VAC)220 / 230; 253 / 257
Rated frequency (Hz)53/63
Switching time (s)<35
Switching time in fast switching mode (ms)< 20
Power factor cos φ0–1 individuals/container
Efficiency
Nighttime standby loss (W)16
European efficiency at 240 / 600 / 870 VDC (%)97,08 / 97,95 / 96,93
Maximum efficiency (%)97,52
Operating conditions and protection
Protection class1
Device EMC emission classB
Pollution degree3
Permissible ambient temperature (°C)- 40°C – +60°C
Permissible storage temperature (°C)-40°C – +70°C
Relative humidity (%)0–100
Sound pressure level (dB(A))50.3 dB(A) (ref. 20 µPA)
Degree of protectionIP66
Dimensions and weight
Dimensions: height × width × depth (mm)865 × 574 × 279
Inverter weight (kg)40,1
General information
Inverter topologynon-isolated, transformerless

Official distribution