Inverter – FRONIUS – Verto 33.3 Plus – hybrid – HV

SKU: 4,210,460
Manufacturer

Net depth

Weight 43 kg
Price 5 327,02 €
Incl. VAT

5 327,02 €
Incl. VAT

In stock:

5 pcs
Log in to place an order

5 327,02 €
Incl. VAT

In stock:

5 pcs
Log in to place an order

Product details

Manufacturer

Net depth

Weight 43 kg

Verto Plus 33.3

Verto Plus 33.3 is a three-phase, transformerless photovoltaic inverter with a rated power of 33.3 kW, equipped with a DC battery input. Three MPPT controllers support a photovoltaic array with a maximum total power of 50 kWp. The device also offers Full Backup mode with an AC-Boost function for short-term power increases.

Key benefits of Verto Plus 33.3

  • Rated power 33.3 kW and a three-phase grid connection.
  • 3 MPPT controllers with an MPP voltage range of 410–870 VDC and support for a PV array with a maximum total power of 50 kWp.
  • Battery DC input: voltage 150–700 V, maximum current 50 A and maximum power 35 kW.
  • Full backup power supply Full Backup: rated power of 33.3 kW and 50 kVA with AC-Boost function for 5–10 s.
  • Fast switching: switching time below 20 ms in fast switching mode; standard switching time below 35 s.
  • IP66 protection rating and permissible ambient temperature from −40 to +60°C.

Who is this a good choice for?

Verto Plus 33.3 is designed for owners of photovoltaic systems requiring a three-phase inverter with a power rating of 33.3 kW. For users planning to connect a battery, it offers a DC input with a maximum power of 35 kW, and for those needing backup power — Full Backup mode with the AC-Boost function.

ParameterValue
DC input data
Maximum input voltage at 1000 W/m² and -10°C under open-circuit conditions (V DC)1000
Start-up voltage (V DC)150
MPP voltage range (V DC)410–870
Number of MPPT controllers3
Maximum input current PV1 / PV2 / PV3 (A)28 / 28 / 28
Maximum input current per string (A)28
Total maximum short-circuit current (A)150
Maximum short-circuit current PV1 / PV2 / PV3 (A)50 / 50 / 50
Maximum short-circuit current per string (A)50
Total maximum PV array power (kWp)50
Maximum PV array power for PV1 / PV2 / PV3 (kWp)20 / 20 / 20
DC overvoltage category2
Maximum inverter reverse current (A)0
Maximum photovoltaic generator capacitance to ground (nF)6 660
Insulation and residual current monitoring
Factory-set insulation resistance limit between the photovoltaic generator and ground (kΩ)34
Insulation resistance monitoring setting range (kΩ)34–10 000
Factory-set limits and detection times for sudden residual current (mA / ms)30 / 300; 60 / 150; 90 / 40
Factory-set limit value and detection time for continuous residual current (mA / ms)300 / 300
Continuous residual current detection setting range (mA)30-1000
Factory-set interval for periodic insulation resistance checks (h)24
Setting range for repeated cyclic insulation resistance checks--
Battery DC input data
Maximum voltage (V)700
Minimum voltage (V)150
Maximum current (A)50
Maximum power (kW)35
Number of DC inputs1
AC output data
Grid voltage range (V AC)176–528
Rated grid voltage (V AC)220 / 230; 253 / 257
Rated power (kW)33,3
Maximum usable inverter DC power (kW)39
Rated apparent power (kVA)33,3
Rated frequency (Hz)50/60 ¹)
Maximum output current per phase (A)53,7
Initial symmetrical short-circuit current per phase IK″ (A)53,7
Power factor cos φ0–1 individuals/container
Grid connection (V AC)3~ (N)PE 380 / 220; 3~ (N)PE 400 / 230; 3~ (N)PE 440 / 253; 3~ (N)PE 480 / 277
Earthing systemsTT (permitted if UN_PE <30 V); TN-S(permitted); TN-C-S(permitted); IT(not permitted)
Maximum output power (kW)33,3
Rated output current per phase (A)50,5 / 48,3 / 43,7 / 40,1
Total harmonic distortion (%)<3%
AC overvoltage category3
Peak inrush current (A)24,72
RMS inrush current (A)6,82
Inrush current duration (ms)1,99
Maximum output short-circuit current and duration (A / ms)53,74 / 13,51
AC output data in full backup power mode
Maximum output current per phase (A)53,7
Output current with 3 phases in AC-Boost mode for 5–10 s (A)72,5
Output current with 1 phase in AC-Boost mode for 5–10 s (A)72,5
Rated output power (kW)33,3
Apparent power in AC-Boost mode for 5–10 s (kVA)50
Rated output current per phase (A)53,7
Rated grid voltage (V AC)3~ (N)PE 380 / 220; 3~ (N)PE 400 / 230; 3~ (N)PE 440 / 253; 3~ (N)PE 480 / 277
Rated frequency (Hz)50/60 ¹)
Switching time (s)<35
Switching time in fast switching mode (ms)<20
Power factor cos φ0–1 individuals/container
Efficiency
Nighttime standby losses (W)16
European efficiency at 400/600/870 V DC (%)97,42 / 97,95 / 97,56
Maximum efficiency (%)97,72
Operating conditions and protection
Protection class1
Device EMC emission classB
Pollution degree3
Permissible ambient temperature (°C)- 40 – +60°C
Permissible storage temperature (°C)-40 – +70°C
Relative humidity (%)0-100%
Sound pressure level (dB(A))56.7 dB(A) (ref. 20 µPA)
Degree of protectionIP66
Dimensions and weight
Dimensions: height × width × depth (mm)865 × 574 × 279
Inverter weight (kg)40,1
General information
Inverter topologynon-isolated, transformerless