Energy storage system – HUAWEI – LUNA2000-241KWH-2S1 – HV

SKU: LUNA2000-241KWH-2S1
Manufacturer

Net depth

Weight 2800 kg
Price 52 954,50 €
Incl. VAT

52 954,50 €
Incl. VAT

52 954,50 €
Incl. VAT

Product details

Manufacturer

Net depth

Weight 2800 kg

LUNA2000-241-2S1

LUNA2000-241-2S1 is a Huawei energy storage system with grid-forming capability, designed for commercial and industrial applications. It uses LFP cells and hybrid cooling, offering a rated capacity of 241.0 kWh and a rated output power of 108 kW. Active balancing and automatic state-of-charge calibration support battery management.

Key benefits of LUNA2000-241-2S1

  • Capacity 241.0 kWh and power 108 kW — a system based on LFP cells, consisting of four battery packs.
  • Maximum cycle efficiency 91.3% and a charging and discharging depth range of 0–100%.
  • Hybrid cooling and an operating temperature range from -30 to 55°C, with performance derating above 50°C.
  • Multi-component fire protection — pack-level oxygen barrier, directional gas venting, top explosion relief vent and aerosol.
  • IP55 protection rating, type II surge protection on the AC side and safeguards including residual current detection and insulation resistance monitoring.
  • Communication via Ethernet or fiber optics using the Modbus TCP protocol.

Who is this a good choice for?

This solution is designed for commercial and industrial businesses requiring an energy storage system with a capacity of 241.0 kWh and an output power of 108 kW. Grid-forming capability, automatic state-of-charge calibration and Modbus TCP communication meet the needs of users who require these features in their energy storage system. This datasheet is preliminary; specific project details must be confirmed with a Huawei engineer.

ParameterValue
Energy storage system specifications
ModelLUNA2000-241-2S1
Rated capacity (kWh)241,0
Maximum cycle speed (CP)0,45
Maximum cycle efficiency (%)91,3
Depth of charge and discharge (%)0~100
Temperature control modeHybrid cooling
Balancing modeActive
SOC calibration modeAutomatic
Battery parameters (DC)
Cell materialLFP
Rated battery capacity (Ah)314
Battery configuration240S1P
Number of battery packs4
Operating voltage range (V)648~852
Rated DC current (A)155,9
PCS converter parameters (AC)
PCS converter modelPCS2000-108K-MB1
Rated output power (kW)108
Rated AC current (A)155,9
AC voltage (V)380 / 400 / 415
AC connection layout3P4W
AC frequency (Hz)50 / 60
Power factor adjustment range-1 ... +1
AC current total harmonic distortion THDi at rated output power in grid-connected operation (%)≤1,5
AC voltage harmonic distortion THDu under linear load in off-grid operation (%)≤2,0
Auxiliary power supply
Auxiliary power supply voltage range (V AC)176~300
Number of auxiliary power supply phases1
Auxiliary power supply rating (kW)≤5
Standby power consumption (W)≤150
Dimensions and weight
Dimensions (W × D × H) (mm)1150×1800×2100
Weight (t)<2,8
Operating conditions
Operating temperature range (°C)-30 ~ 55
Temperature above which power derating occurs (°C)>50
Storage temperature range (°C)-35 ~ 60
Operating relative humidity range (%)0 ~ 100 (non-condensing)
Maximum operating altitude above sea level (m)4,000
Noise level under rated operating conditions (dB(A))≤65
Communication
Communication interfaceEthernet / fiber optic
Communication protocolModbus TCP
Protection
Protection ratingIP55
EMC protection classB
Surge protectionType II (AC port)
Fire protection systemPack-level oxygen barrier, directional gas venting, top explosion relief vent, aerosol
Protection featuresAnti-islanding protection, residual current detection, insulation resistance monitoring, AC overcurrent protection, AC wiring connection protection
Certificates and standards
Environmental complianceRoHS6
Standards and certificationsUL9540A; UN38.3; IEC 62477-1; IEC 62040-1; IEC 61000-6-1/2/3/4; IEC 62619; IEC 60529; VDE-AR-E 2510-2/50; IEC 62933-5-1/2; IEC 61727; EN 50549; GB/T 34120

Rated operating conditions: grid-connected operation, ambient temperature 25°C, charge/discharge rate 0.45 CP, output voltage 400 V AC. Data are from a preliminary version.

Official distribution