Energy storage system – GOODWE – GW61.4-BAT-AC-G10 – 61.4 kWh – HV
Product details
BAT
BAT is a high-voltage energy storage system from GoodWe for outdoor installation in commercial and industrial applications. It uses LFP (LiFePO4) cells and an integrated cabinet design, and works with GoodWe ET series hybrid inverters and an STS box. Parallel connection capability allows the system to expand as energy storage needs grow.
Key benefits of BAT
- Nominal energy 61.4–112.6 kWh and usable energy of 60–110 kWh, depending on the variant and system configuration.
- Scalability up to 4 devices connected in parallel and a total nominal energy of up to 450.4 kWh.
- LFP cells and 6-layer safety protection, including an aerosol fire suppression system at module and cabinet level.
- Charging up to 0.9C and discharging up to 1.1C; actual performance and continuous operating time depend on the state of charge and temperature.
- IP55 protection rating and air conditioning cooling with an operating temperature range from -20 to +55°C.
- Cycle efficiency 96% at 100% depth of discharge, 0.2C charging and discharging, and a temperature of 25 ± 2°C.
Who is this a good choice for?
BAT is designed for businesses requiring outdoor energy storage for medium and large commercial and industrial applications. It meets the needs of users at industrial parks, agricultural and commercial complexes who plan to expand system capacity by connecting units in parallel and expect fire protection at both module and cabinet level.
| Parameter | GW61.4-BAT-AC-G10 | GW112.6-BAT-AC-G10 |
|---|---|---|
| Battery system | ||
| Cell type | LFP (LiFePO4) | |
| Cell capacity (Ah) | 100 | |
| Rated capacity (Ah) | 200 | |
| Set model | GW10.2-PACK-ACI-G10 | |
| Nominal energy of the set (kWh) | 10,24 | |
| Kit configuration | 2P96S | 2P176S |
| Set weight (kg) | <90 | |
| Number of sets | 6 | 11 |
| Nominal energy (kWh) | 61,4 | 112,6 |
| Usable energy (kWh) | 60 | 110 |
| Nominal voltage (V) | 307,2 | 563,2 |
| Operating voltage range (V) | 275,52 ~ 346,56 | 505,12 ~ 635,36 |
| Maximum charging / discharging current (A) | 180 / 220 | |
| Maximum charging / discharging rate (C) | 0,9 / 1,1 | |
| Maximum charging / discharging power (kW) | 55,2 / 67,5 | 101,3 / 123,9 |
| Service life (cycles) | 6000 (25 ± 2°C, 0.5C, 90% DOD, 70% EOL) | |
| Depth of discharge (%) | 100 | |
| Efficiency | ||
| Cycle efficiency (%) | 96 (100% DOD, 0.2C, 25 ± 2°C) | |
| Operating conditions | ||
| Operating temperature range during charging (°C) | -20 ~ +55 | |
| Operating temperature range during discharge (°C) | -20 ~ +55 | |
| Operating temperature range (°C) | -20 ~ +55 | |
| Storage temperature (°C) | +35 ~ +45 (<6 months); -20 ~ +35 (<1 year) | |
| Relative humidity (%) | 0 ~ 100 (non-condensing) | |
| Maximum working height (m) | 4000 | |
| Cooling method | Air conditioner | |
| Protection rating | IP55 | |
| Corrosion resistance class | C4 (optionally C5-M) | |
| Dimensions and weight | ||
| Weight (kg) | <950 | <1400 |
| Dimensions (W × H × D) (mm) | 1055 × 2000 × 1055 | |
| Communication and operation | ||
| User interface | LED | |
| Communication | CAN (optional RS485) | |
| Safety and certifications | ||
| Fire protection system | Aerosol (module and cabinet level) | |
| Safety standards | IEC62619 / IEC63056 / IEC60730 / IEC62477 / VDE2510 / ISO13849 IEC62040 / N140 / EU 2023 / 1542 / UN38.3 | |
| Electromagnetic compatibility | IEC / EN61000-6-1 / 2 / 3 / 4 | |
Usable energy depends on the system configuration; measured at the start of service life at 100% DOD and +25 ± 2°C. Actual charging and discharging current and power depend on cell temperature and state of charge. Continuous operating time also depends on ambient temperature.