Inverter – GOODWE – GW6000-ET-20 – hybrid – HV

| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 28,76 kg |
| CN | 85044084 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 28,76 kg |
| CN | 85044084 |
GoodWe ET G2 (Series GW6000-ET-20 – GW15K-ET-20)
The GoodWe ET G2 three-phase hybrid inverter series is designed to maximize energy yield, increase self-consumption and provide stable and uninterrupted backup power (UPS). The device offers a rated AC output power from 6 kW to 15 kW and works with high-voltage lithium-ion batteries, serving as a reliable heart of a modern photovoltaic system. With intelligent operating modes and a built-in smart meter, the system allows optimization of energy consumption and reduction of electricity bills.
Key features of GoodWe ET G2:
- High efficiency: Maximum inverter efficiency up to 98.2% ensures effective conversion of solar energy into usable electricity.
- Backup power: Reliable support in backup (UPS) mode with short response time and high apparent power in case of grid outage.
- Design flexibility: Equipped with 2 to 3 independent MPPT trackers (depending on the model) enables optimal matching to PV installations with complex roof geometries.
- Wide battery voltage range: Supports high-voltage energy storage from 150 V to 720 V for efficient storage of excess energy.
- Safety and durability: IP66 protection rating, surge protectors on DC and AC circuits and comprehensive protection systems ensure long and reliable operation.
Who is this a good choice for?
The GoodWe ET G2 hybrid inverter series is an excellent solution for single-family homeowners and smaller commercial properties looking for an advanced energy management system with the option to expand with energy storage. It is an ideal choice for investors who want to become less dependent on rising electricity prices, protect the building from power outages and fully control energy flows in the household.
| Parameter | GW6000-ET-20 | GW8000-ET-20 | GW10K-ET-20 | GW12K-ET-20 | GW15K-ET-20 |
|---|---|---|---|---|---|
| Battery input parameters | |||||
| Battery type | Li-Ion | Li-Ion | Li-Ion | Li-Ion | Li-Ion |
| Battery nominal voltage (V) | 500 | 500 | 500 | 500 | 500 |
| Battery voltage range (V) | 150–720 | 150–720 | 150–720 | 150–720 | 150–720 |
| Start-up voltage (V) | 150 | 150 | 150 | 150 | 150 |
| Number of battery inputs | 1 | 1 | 1 | 1 | 1 |
| Max. continuous charging current (A) | 30 | 30 | 40 | 40 | 40 |
| Max. continuous discharging current (A) | 30 | 30 | 40 | 40 | 40 |
| Max. charging power (W) | 9000 | 12000 | 15000 | 18000 | 24000 |
| Max. discharging power (W) | 6600 | 8800 | 11000 | 13200 | 16500 |
| PV string input parameters | |||||
| Max. input power (W)*1 | 9600 | 12800 | 16000 | 19200 | 24000 |
| Max. input voltage (V)*2 | 1000 | 1000 | 1000 | 1000 | 1000 |
| MPPT operating voltage range (V) | 120–850 | 120–850 | 120–850 | 120–850 | 120–850 |
| Start-up voltage (V) | 150 | 150 | 150 | 150 | 150 |
| Rated input voltage (V) | 620 | 620 | 620 | 620 | 620 |
| Max. input current per MPPT (A) | 16 | 16 | 16 | 16 | 16 |
| Max. short-circuit current per MPPT (A) | 24 | 24 | 24 | 24 | 24 |
| Number of MPPTs | 2 | 2 | 3 | 3 | 3 |
| Number of PV module strings per MPPT | 1 | 1 | 1 | 1 | 1 |
| AC output parameters (to grid) | |||||
| Rated output power (W) | 6000 | 8000 | 10000 | 12000 | 15000 |
| Rated apparent power to the grid (VA) | 6000 | 8000 | 10000 | 12000 | 15000 |
| Max. apparent output power to the grid (VA)*3 | 6000 | 8000 | 10000 | 12000 | 15000 |
| Max. apparent power from the grid (VA) | 12000 | 16000 | 20000 | 20000 | 20000 |
| Rated output voltage (V) | 400/380, 3L/N/PE | 400/380, 3L/N/PE | 400/380, 3L/N/PE | 400/380, 3L/N/PE | 400/380, 3L/N/PE |
| Output voltage range (V)*4 | 170–290 | 170–290 | 170–290 | 170–290 | 170–290 |
| Rated AC grid frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| AC grid frequency range (Hz) | 45–65 | 45–65 | 45–65 | 45–65 | 45–65 |
| Max. AC output current to the grid (A)*5 | 8.7 | 11.6 | 14.5 | 17.4 | 21.7 |
| Max. AC current from the grid (A) | 15.7 | 21.0 | 26.1 | 26.1 | 26.1 |
| Power factor adjustment range | from 0.8 leading to 0.8 lagging | from 0.8 leading to 0.8 lagging | from 0.8 leading to 0.8 lagging | from 0.8 leading to 0.8 lagging | from 0.8 leading to 0.8 lagging |
| Total Harmonic Distortion THD (%) | <3% | <3% | <3% | <3% | <3% |
| AC output parameters (backup circuit) | |||||
| Backup rated apparent power (VA) | 6000 | 8000 | 10000 | 12000 | 15000 |
| Max. apparent output power without grid (VA) | 6000 (12000 @60sek.)*6 | 8000 (16000 @60sek.)*6 | 10000 (18000 @60sek.)*6 | 12000 (18000 @60sek.)*6 | 15000 (18000 @60sek.)*6 |
| Max. apparent output power with grid (VA) | 6000 | 8000 | 10000 | 12000 | 15000 |
| Max. output current (A) | 13.0 (17.4 @60sek.) | 17.4 (23.3 @60sek.) | 21.7 (26.1 @60sek.) | 21.7 (26.1 @60sek.) | 21.7 (26.1 @60sek.) |
| Rated output voltage (V) | 400/380 | 400/380 | 400/380 | 400/380 | 400/380 |
| Rated output frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| THDV distortion on output (at linear load) | <3% | <3% | <3% | <3% | <3% |
| Efficiency | |||||
| Max. efficiency (%) | 98.0% | 98.0% | 98.2% | 98.2% | 98.2% |
| European efficiency (%) | 97.2% | 97.2% | 97.5% | 97.5% | 97.5% |
| Max. battery efficiency under load (%) | 97.2% | 97.5% | 97.5% | 97.5% | 97.5% |
| MPPT efficiency (%) | 99.5% | 99.5% | 99.5% | 99.5% | 99.5% |
| Protections | |||||
| PV insulation resistance detection | Integrated | Integrated | Integrated | Integrated | Integrated |
| PV AFCI | Optional | Optional | Optional | Optional | Optional |
| Residual current monitoring | Integrated | Integrated | Integrated | Integrated | Integrated |
| Reverse polarity protection on DC circuit | Integrated | Integrated | Integrated | Integrated | Integrated |
| Reverse polarity protection on energy storage power circuit | Integrated | Integrated | Integrated | Integrated | Integrated |
| Anti-islanding protection | Integrated | Integrated | Integrated | Integrated | Integrated |
| AC overcurrent protection | Integrated | Integrated | Integrated | Integrated | Integrated |
| AC short circuit protection | Integrated | Integrated | Integrated | Integrated | Integrated |
| AC surge protection | Integrated | Integrated | Integrated | Integrated | Integrated |
| DC isolator | Integrated | Integrated | Integrated | Integrated | Integrated |
| DC surge protector | Type II | Type II | Type II | Type II | Type II |
| AC surge protector | Type II | Type II | Type II | Type II | Type II |
| Remote shutdown | Integrated | Integrated | Integrated | Integrated | Integrated |
| General data | |||||
| Operating temperature range (°C) | -35 ~ +60 | -35 ~ +60 | -35 ~ +60 | -35 ~ +60 | -35 ~ +60 |
| Relative humidity (%) | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
| Max. operating altitude above sea level (m) | 4000 | 4000 | 4000 | 4000 | 4000 |
| Cooling method | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection |
| Display | LED, WLAN + APP | LED, WLAN + APP | LED, WLAN + APP | LED, WLAN + APP | LED, WLAN + APP |
| Communication with BMS | RS485, CAN | RS485, CAN | RS485, CAN | RS485, CAN | RS485, CAN |
| Communication with meter | RS485 | RS485 | RS485 | RS485 | RS485 |
| Communication with portal | WiFi + LAN + Bluetooth | WiFi + LAN + Bluetooth | WiFi + LAN + Bluetooth | WiFi + LAN + Bluetooth | WiFi + LAN + Bluetooth |
| Weight (kg) | 23 | 23 | 25 | 25 | 25 |
| Dimensions (W × H × D) (mm) | 496 × 460 × 221 | 496 × 460 × 221 | 496 × 460 × 221 | 496 × 460 × 221 | 496 × 460 × 221 |
| Noise emission (dB) | <30 | <30 | <45 | <45 | <45 |
| Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
| Night power consumption (W)*7 | <15 | <15 | <15 | <15 | <15 |
| Protection rating IP | IP66 | IP66 | IP66 | IP66 | IP66 |
| Mounting method | Wall mounting | Wall mounting | Wall mounting | Wall mounting | Wall mounting |
*1: Max. input power, non-continuous, up to 1.6 times the normal power.
*2: For a 1000V system, the maximum operating voltage is 950V.
*3: In accordance with local grid regulations.
*4: Output voltage range: phase voltage.
*5: The maximum AC current at the output to the grid load is respectively 13A, 17.4A, 21.7A, 21.7A, 21.7A.
*6: Only possible with sufficient PV panel and battery power.
*7: No backup output.