Energy meter – EASTRON – SDM630MCT – dedicated to SOLPLANET inverters – 3-phase

SKU: F280Z31 EAN: 2010000044704
Manufacturer

Net width

Net depth

Net height

Weight 0,3 kg
CN 90283019
Price 167,03 €
Incl. VAT

167,03 €
Incl. VAT

167,03 €
Incl. VAT

Product details

Manufacturer

Net width

Net depth

Net height

Weight 0,3 kg
CN 90283019

SDM630MCT Series

Advanced, multifunctional three-phase electricity meter for DIN-rail mounting, designed to work with current transformers (CT 1A/5A or optionally 333 mV). The device offers bidirectional measurement of energy and network parameters, a high level of accuracy and MID B+D certification. With flexible communication options, it is ideal for modern energy consumption monitoring systems in single- and three-phase installations.

Key features of the SDM630MCT Series:

  • Versatile measurement: Supports single-phase (2-wire) and three-phase (3- and 4-wire) installations with bidirectional measurement of active and reactive energy.
  • MID B+D certification: Compliance with the EU directive 2014/32/EU (SGS certificate) ensuring the legality of billing.
  • High accuracy: Available accuracy class 1.0 for active energy (standard) or optional class 0.5 in selected models.
  • Flexible communication: Built-in pulse outputs and optional RS485 Modbus RTU or M-Bus ports for remote data reading.
  • Multi-parameter and multi-tariff: Measurement of parameters such as voltage, current, active, reactive and apparent power, frequency, power factor and support for multiple tariffs (in selected versions).
  • Easy installation and operation: Compact DIN-rail enclosure 72 mm wide, IP51 protection rating and a clear backlit LCD display.

Who is this a good choice for?

The SDM630MCT Series is an excellent choice for building managers, energy auditors and installers of home and industrial automation systems who need a reliable and precise tool for submetering and monitoring electricity consumption. Thanks to MID certification, a wide range of communication interfaces and easy DIN-rail mounting, the device performs perfectly in commercial, residential and industrial applications requiring remote collection of measurement data.

Parameter SDM630MCT-Modbus SDM630MCT-MODBUS-0.5 SDM630MCT-Mbus SDM630MCT-2T SDM630MCT-MV
Electrical parameters
Rated voltage Un (V AC) 3×230/400 3×230/400 3×230/400 3×230/400 3×230/400
Operating voltage range 80% – 120% Un 80% – 120% Un 80% – 120% Un 80% – 120% Un 80% – 120% Un
Current input type / rated current (Ib) CT 1 A / 5 A CT 1 A / 5 A CT 1 A / 5 A CT 1 A / 5 A 333 mV input
Operating current range 0.4% Ib – Imax 0.4% Ib – Imax 0.4% Ib – Imax 0.4% Ib – Imax 0.4% Ib – Imax
Current overload withstand 20 Imax for 0.01 s 20 Imax for 0.01 s 20 Imax for 0.01 s 20 Imax for 0.01 s 20 Imax for 0.01 s
Rated frequency (Hz) 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60
AC withstand voltage (kV) 4 (for 1 min) 4 (for 1 min) 4 (for 1 min) 4 (for 1 min) 4 (for 1 min)
Impulse withstand voltage (kV) 6 (1.2 µs) 6 (1.2 µs) 6 (1.2 µs) 6 (1.2 µs) 6 (1.2 µs)
Power consumption per phase ≤ 2 W / 10 VA ≤ 2 W / 10 VA ≤ 2 W / 10 VA ≤ 2 W / 10 VA ≤ 2 W / 10 VA
Measurement accuracy
Accuracy class (active energy) Class 1.0 / Class B Class 0.5 Class 1.0 / Class B Class 1.0 / Class B Class 1.0 / Class B
Voltage and current ±0.5% of full scale ±0.5% of full scale ±0.5% of full scale ±0.5% of full scale ±0.5% of full scale
Frequency 0.2% of nominal frequency 0.2% of nominal frequency 0.2% of nominal frequency 0.2% of nominal frequency 0.2% of nominal frequency
Power factor 1% of unity (0.01) 1% of unity (0.01) 1% of unity (0.01) 1% of unity (0.01) 1% of unity (0.01)
Active and apparent power ±1% of full scale ±1% of full scale ±1% of full scale ±1% of full scale ±1% of full scale
Reactive power ±1% of full scale ±1% of full scale ±1% of full scale ±1% of full scale ±1% of full scale
Reactive energy Class 2 Class 2 Class 2 Class 2 Class 2
Communication and interfaces
Interface / bus protocol RS485 / Modbus RTU RS485 / Modbus RTU M-Bus / EN13757-3 RS485 / Modbus RTU RS485 / Modbus RTU
Communication speed (bps) 2400 / 4800 / 9600 / 19200 / 38400 2400 / 4800 / 9600 / 19200 / 38400 300 / 600 / 1200 / 2400 / 4800 / 9600 2400 / 4800 / 9600 / 19200 / 38400 2400 / 4800 / 9600 / 19200 / 38400
Number of supported tariffs 1 tariff 1 tariff 1 tariff 2 tariffs 1 tariff
Pulse output 1 Configurable Configurable Configurable Configurable Configurable
Pulse output 2 3200 imp/kWh 3200 imp/kWh 3200 imp/kWh 3200 imp/kWh 3200 imp/kWh
Display and user parameters
Display type Backlit LCD Backlit LCD Backlit LCD Backlit LCD Backlit LCD
Maximum reading 9999999.9 kWh / kVarh 9999999.9 kWh / kVarh 9999999.9 kWh / kVarh 9999999.9 kWh / kVarh 9999999.9 kWh / kVarh
Environmental conditions and construction
Operating temperature (°C) -25 to +55 -25 to +55 -25 to +55 -25 to +55 -25 to +55
Storage temperature (°C) -40 to +70 -40 to +70 -40 to +70 -40 to +70 -40 to +70
Operating humidity (%) ≤ 90 ≤ 90 ≤ 90 ≤ 90 ≤ 90
Storage humidity (%) ≤ 95 ≤ 95 ≤ 95 ≤ 95 ≤ 95
Protection rating IP51 (indoor use) IP51 (indoor use) IP51 (indoor use) IP51 (indoor use) IP51 (indoor use)
Protection class II II II II II
Pollution degree 2 2 2 2 2
Installation category CAT III CAT III CAT III CAT III CAT III
Mounting DIN rail DIN rail DIN rail DIN rail DIN rail
Dimensions (W × H × D) (mm) 72 × 94.5 × 65 72 × 94.5 × 65 72 × 94.5 × 65 72 × 94.5 × 65 72 × 94.5 × 65

Official distribution