Inverter – DEYE – SUN-6K-SG06LP1-EU-BM2 – 1 fazowy – hybrydowy – LV

SKU: F20GW11 EAN: 2010000042885
Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

CAN

CAN 2.0

RS485

SPD Type I

SPD Type II

SPD Type I+II

SPD – Free slot

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

CN 85044085
Price 800,73 €
Incl. VAT

800,73 €
Incl. VAT

Delivery time: 5 days

In stock:

5 pcs
Log in to place an order

800,73 €
Incl. VAT

Delivery time: 5 days

In stock:

5 pcs
Log in to place an order

Product details

Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

CAN

CAN 2.0

RS485

SPD Type I

SPD Type II

SPD Type I+II

SPD – Free slot

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

CN 85044085

Deye Series SUN-SG06LP1

The single-phase hybrid inverters from Deye’s SUN-SG06LP1 series are modern devices designed for energy management in photovoltaic installations, offering rated power from 3 kW to 6 kW. They provide a high degree of flexibility thanks to support for low-voltage batteries (24V or 48V depending on the model) and advanced on-grid and off-grid operating functions. With a robust IP65-rated enclosure and a clear color LCD touchscreen, these inverters are a reliable and intuitive solution for any home.

Key features of Deye Series SUN-SG06LP1:

  • High flexibility and safety: IP65 protection rating allows outdoor installation, and the color LCD touchscreen simplifies device operation.
  • Intelligent energy management: Configurable up to 6 time periods for battery charging and discharging.
  • Greater independence: Charging and discharging current up to 140 A and the ability to operate in parallel up to 16 units in on-grid and off-grid systems.
  • Expansion of existing systems: AC coupling capability to upgrade older photovoltaic installations.
  • Versatile power support: Supports energy storage from diesel generators and automatic adaptation to lithium-ion battery BMS.
  • High efficiency and safety: Maximum efficiency up to 97.6% and comprehensive electrical protections, including type II surge protection and an optional arc-fault circuit interrupter (AFCI).

Who is this a good choice for?

This series of hybrid inverters is an excellent choice for owners of single-family homes looking for reliable energy storage systems with power from 3 to 6 kW. It is suitable both for new photovoltaic installations and for upgrading older systems thanks to the AC coupling function. It is an ideal solution for those wishing to increase self-consumption, provide emergency power during outages, or integrate the inverter with a combustion generator.

Parameter SUN-3K-SG06LP1-24-EU-BM1 SUN-3K-SG06LP1-EU-BM1 SUN-3.6K-SG06LP1-EU-BM2 SUN-4K-SG06LP1-EU-BM2 SUN-4.6K-SG06LP1-EU-BM2 SUN-5K-SG06LP1-EU-BM2 SUN-6K-SG06LP1-EU-BM2
Battery input data
Battery type Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion
Battery voltage range (V) 20–30 40–60 40–60 40–60 40–60 40–60 40–60
Max. charging / discharging current (A) 140 70 90 95 120 120 135
Lithium-ion battery charging strategy Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS
Number of battery inputs 1 1 1 1 1 1 1
PV string input data
Max. PV connected power (W) 6000 6000 7200 8000 9200 10000 12000
Max. PV input power (W) 4800 4800 5760 6400 7360 8000 9600
Max. PV input voltage (V) 500 500 500 500 500 500 500
Start-up voltage (V) 125 125 125 125 125 125 125
MPPT voltage range (V) 150–425 150–425 150–425 150–425 150–425 150–425 150–425
Rated PV input voltage (V) 370 370 370 370 370 370 370
Max. operating PV input current (A) 18 18 18+18 18+18 18+18 18+18 18+18
Max. PV input short-circuit current (A) 27 27 27+27 27+27 27+27 27+27 27+27
Number of MPPT trackers / Number of strings per MPPT tracker 1/1 1/1 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1
AC input/output data
Rated active AC input/output power (W) 3000 3000 3600 4000 4600 5000 6000
Max. apparent AC input/output power (VA) 3300 3300 3960 4400 4600 5500 6600
Rated AC input/output current (A) 13,7/13,1 13,7/13,1 16,4/15,7 18,2/17,4 21/20 22,8/21,8 27,3/26,1
Max. AC input/output current (A) 15/14,4 15/14,4 18/17,3 20/19,2 21/20 25,0/24,0 30/28,7
Max. continuous AC flow (grid to load) (A) 50 50 50 50 50 50 50
Peak power (off-grid) (W) 2-krotność mocy znamionowej, 10 s 2-krotność mocy znamionowej, 10 s 2-krotność mocy znamionowej, 10 s 2-krotność mocy znamionowej, 10 s 2-krotność mocy znamionowej, 10 s 2-krotność mocy znamionowej, 10 s 2-krotność mocy znamionowej, 10 s
Power factor regulation range 0,8 wyprzedzający do 0,8 opóźniony 0,8 wyprzedzający do 0,8 opóźniony 0,8 wyprzedzający do 0,8 opóźniony 0,8 wyprzedzający do 0,8 opóźniony 0,8 wyprzedzający do 0,8 opóźniony 0,8 wyprzedzający do 0,8 opóźniony 0,8 wyprzedzający do 0,8 opóźniony
Rated input/output voltage 220/230 V 0,85Un-1,1Un L+N+PE 220/230 V 0,85Un-1,1Un L+N+PE 220/230 V 0,85Un-1,1Un L+N+PE 220/230 V 0,85Un-1,1Un L+N+PE 220/230 V 0,85Un-1,1Un L+N+PE 220/230 V 0,85Un-1,1Un L+N+PE 220/230 V 0,85Un-1,1Un L+N+PE
Rated frequency / grid frequency range (Hz) 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65 50/45-55, 60/55-65
Total harmonic distortion of current THDi <3% (mocy nominalnej) <3% (mocy nominalnej) <3% (mocy nominalnej) <3% (mocy nominalnej) <3% (mocy nominalnej) <3% (mocy nominalnej) <3% (mocy nominalnej)
DC current component <0,5% In <0,5% In <0,5% In <0,5% In <0,5% In <0,5% In <0,5% In
Efficiency
Maximum efficiency (%) 97,6% 97,6% 97,6% 97,6% 97,6% 97,6% 97,6%
European efficiency (%) 96,5% 96,5% 96,5% 96,5% 96,5% 96,5% 96,5%
MPPT efficiency (%) >99% >99% >99% >99% >99% >99% >99%
Device protection
Integrated protections DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Arc-fault circuit interrupter (AFCI) (optional), Anti-islanding protection, DC switch, Insulation impedance detection, Residual current detection DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Arc-fault circuit interrupter (AFCI) (optional), Anti-islanding protection, DC switch, Insulation impedance detection, Residual current detection DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Arc-fault circuit interrupter (AFCI) (optional), Anti-islanding protection, DC switch, Insulation impedance detection, Residual current detection DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Arc-fault circuit interrupter (AFCI) (optional), Anti-islanding protection, DC switch, Insulation impedance detection, Residual current detection DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Arc-fault circuit interrupter (AFCI) (optional), Anti-islanding protection, DC switch, Insulation impedance detection, Residual current detection DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Arc-fault circuit interrupter (AFCI) (optional), Anti-islanding protection, DC switch, Insulation impedance detection, Residual current detection DC reverse polarity protection, AC output overcurrent protection, Thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, Arc-fault circuit interrupter (AFCI) (optional), Anti-islanding protection, DC switch, Insulation impedance detection, Residual current detection
Surge protection level TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC)
Interface
Display LCD LCD LCD LCD LCD LCD LCD
Communication interface WIFI, RS485, CAN WIFI, RS485, CAN WIFI, RS485, CAN WIFI, RS485, CAN WIFI, RS485, CAN WIFI, RS485, CAN WIFI, RS485, CAN
General data
Operating temperature range (°C) -40 do +60°C, obniżenie wartości znamionowych >45°C -40 do +60°C, obniżenie wartości znamionowych >45°C -40 do +60°C, obniżenie wartości znamionowych >45°C -40 do +60°C, obniżenie wartości znamionowych >45°C -40 do +60°C, obniżenie wartości znamionowych >45°C -40 do +60°C, obniżenie wartości znamionowych >45°C -40 do +60°C, obniżenie wartości znamionowych >45°C
Permissible ambient humidity 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% 0–100%
Permissible altitude above sea level (m) 3000 3000 3000 3000 3000 3000 3000
Noise level (dB) <45 <45 <45 <45 <45 <45 <45
Protection class (IP) IP65 IP65 IP65 IP65 IP65 IP65 IP65
Inverter topology Transformerless (photovoltaic), Isolated (battery) Transformerless (photovoltaic), Isolated (battery) Transformerless (photovoltaic), Isolated (battery) Transformerless (photovoltaic), Isolated (battery) Transformerless (photovoltaic), Isolated (battery) Transformerless (photovoltaic), Isolated (battery) Transformerless (photovoltaic), Isolated (battery)
Overvoltage category OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC)
Enclosure dimensions (W × H × D) (mm) 310 × 460 × 218 (bez złączy i uchwytów) 310 × 460 × 218 (bez złączy i uchwytów) 310 × 460 × 218 (bez złączy i uchwytów) 310 × 460 × 218 (bez złączy i uchwytów) 310 × 460 × 218 (bez złączy i uchwytów) 310 × 460 × 218 (bez złączy i uchwytów) 310 × 460 × 218 (bez złączy i uchwytów)
Weight (kg) 15,6 15,6 15,6 15,6 15,6 15,6 15,6
Cooling type Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling
Warranty 5 lat / do 10 lat* 5 lat / do 10 lat* 5 lat / do 10 lat* 5 lat / do 10 lat* 5 lat / do 10 lat* 5 lat / do 10 lat* 5 lat / do 10 lat*
Grid standards IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC standards IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

* Okres gwarancji zależy od kraju instalacji. Szczegółowe informacje znajdują się w warunkach gwarancji.