Inverter – SOLAX – X3-MIC-5K-G2
Product details
| Weight | 18,8 kg |
|---|---|
| CN | 85044086 |
SOLAX X3-MIC G2
Three-phase On-Grid inverter SolaX X3-MIC G2 with power from 3 to 15 kW is an advanced solution for photovoltaic installations. The device features high efficiency of up to 98.3% and versatile energy management capabilities. Thanks to its robust construction and intelligent functions, it provides reliable and efficient operation in all conditions.
Key features of the SOLAX X3-MIC G2:
- Maximum efficiency up to 98.3% and a wide MPPT voltage range.
- DC oversizing up to 200% and support for high-power solar panels with 16 A input current per string.
- Built-in export power control function and intelligent load management, e.g. for a heat pump.
- High IP66 protection rating enabling outdoor installation.
- Integrated Type III surge protection devices (SPD) on both AC and DC sides.
- Multiple remote monitoring options via Pocket Wi-Fi, LAN or 4G modules.
Who is this a good choice for?
This inverter is an excellent choice for single-family homeowners and small commercial premises looking for a three-phase, reliable and safe photovoltaic inverter. The wide selection of models with power from 3 to 15 kW allows perfect matching of the installation to the building’s current energy needs.
| Parameter | X3-MIC-3K-G2 | X3-MIC-4K-G2 | X3-MIC-5K-G2 | X3-MIC-6K-G2 | X3-MIC-8K-G2 | X3-MIC-10K-G2 | X3-MIC-12K-G2 | X3-MIC-15K-G2 |
|---|---|---|---|---|---|---|---|---|
| DC INPUT | ||||||||
| Max. PV input power (Wp) | 6000 | 8000 | 10000 | 12000 | 16000 | 20000 | 24000 | 30000 |
| Max. PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
| Start-up voltage (V) | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
| Nominal DC input voltage (V) | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 |
| MPPT voltage range (V) | 120–980 | 120–980 | 120–980 | 120–980 | 120–980 | 120–980 | 120–980 | 120–980 |
| Number of MPPT trackers / Number of strings per MPPT tracker | 2 (1/1) | 2 (1/1) | 2 (1/1) | 2 (1/1) | 2 (1/1) | 2 (1/1) | 2 (2/1) | 2 (2/1) |
| Max. input current (A) | 16 / 16 | 16 / 16 | 16 / 16 | 16 / 16 | 16 / 16 | 16 / 16 | 16 × 2 / 16 | 16 × 2 / 16 |
| Max. short-circuit current (A) | 20 / 20 | 20 / 20 | 20 / 20 | 20 / 20 | 20 / 20 | 20 / 20 | 20 × 2 / 20 | 20 × 2 / 20 |
| AC OUTPUT | ||||||||
| Rated AC output power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 |
| Rated AC output current (A) | 4,6 / 4,4 | 6,1 / 5,8 | 7,6 / 7,3 | 9,1 / 8,7 | 12,2 / 11,6 | 15,2 / 14,5 | 18,2 / 17,4 | 22,7 / 21,8 |
| Max. AC apparent output power (VA) | 3300 | 4400 | 5500 | 6600 | 8800 | 11000 | 13200 | 15000 |
| Max. AC output current (A) | 4,8 | 6,4 | 8,0 | 9,6 | 12,8 | 16,0 | 19,1 | 22,7 |
| Nominal AC voltage (V) | 220/380 V, 230/400 V, 3/N/PE | 220/380 V, 230/400 V, 3/N/PE | 220/380 V, 230/400 V, 3/N/PE | 220/380 V, 230/400 V, 3/N/PE | 220/380 V, 230/400 V, 3/N/PE | 220/380 V, 230/400 V, 3/N/PE | 220/380 V, 230/400 V, 3/N/PE | 220/380 V, 230/400 V, 3/N/PE |
| Nominal grid frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
| Power factor range | 0.8 lead – 0.8 lag | 0.8 lead – 0.8 lag | 0.8 lead – 0.8 lag | 0.8 lead – 0.8 lag | 0.8 lead – 0.8 lag | 0.8 lead – 0.8 lag | 0.8 lead – 0.8 lag | 0.8 lead – 0.8 lag |
| THDi (rated power) (%) | <3 | <3 | <3 | <3 | <3 | <3 | <3 | <3 |
| SYSTEM DATA | ||||||||
| Max. efficiency (%) | 98,3 | 98,3 | 98,3 | 98,3 | 98,3 | 98,3 | 98,3 | 98,3 |
| European efficiency (%) | 97,8 | 97,8 | 97,8 | 97,8 | 97,8 | 97,8 | 97,8 | 97,8 |
| Standby power consumption (at night) (W) | <3 | <3 | <3 | <3 | <3 | <3 | <3 | <3 |
| Ingress protection | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating temperature range (°C) | -30 ~ +60 (derating above +45) | -30 ~ +60 (derating above +45) | -30 ~ +60 (derating above +45) | -30 ~ +60 (derating above +45) | -30 ~ +60 (derating above +45) | -30 ~ +60 (derating above +45) | -30 ~ +60 (derating above +45) | -30 ~ +60 (derating above +45) |
| Max. operating altitude (m) | 4000 (derating above 3000) | 4000 (derating above 3000) | 4000 (derating above 3000) | 4000 (derating above 3000) | 4000 (derating above 3000) | 4000 (derating above 3000) | 4000 (derating above 3000) | 4000 (derating above 3000) |
| Relative humidity (%) | 0–100 | 0–100 | 0–100 | 0–100 | 0–100 | 0–100 | 0–100 | 0–100 |
| Typical noise emission (dB) | <30 | <30 | <30 | <30 | <45 | <45 | <50 | <50 |
| Storage temperature (°C) | -30 ~ +60 | -30 ~ +60 | -30 ~ +60 | -30 ~ +60 | -30 ~ +60 | -30 ~ +60 | -30 ~ +60 | -30 ~ +60 |
| Dimensions (W × H × D) (mm) | 342 × 434 × 144,5 | 342 × 434 × 144,5 | 342 × 434 × 144,5 | 342 × 434 × 144,5 | 342 × 434 × 156 | 342 × 434 × 156 | 342 × 434 × 156 | 342 × 434 × 156 |
| Weight (kg) | 15,5 | 15,5 | 15,5 | 15,5 | 17 | 17 | 18 | 18 |
| Cooling method | Natural cooling | Natural cooling | Natural cooling | Natural cooling | Intelligent fan cooling | Intelligent fan cooling | Intelligent fan cooling | Intelligent fan cooling |
| Communication interfaces | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) | USB / RS485 / DRM / Pocket WiFi (optional: Pocket LAN/4G) / connection box (optional) |
| PROTECTIONS | ||||||||
| Over/under voltage protection | YES | YES | YES | YES | YES | YES | YES | YES |
| DC isolation protection | YES | YES | YES | YES | YES | YES | YES | YES |
| DC reverse polarity protection | YES | YES | YES | YES | YES | YES | YES | YES |
| Grid monitoring | YES | YES | YES | YES | YES | YES | YES | YES |
| DC current monitoring | YES | YES | YES | YES | YES | YES | YES | YES |
| Reverse current monitoring | YES | YES | YES | YES | YES | YES | YES | YES |
| Residual current detection | YES | YES | YES | YES | YES | YES | YES | YES |
| Anti-islanding protection | YES | YES | YES | YES | YES | YES | YES | YES |
| Over-temperature protection | YES | YES | YES | YES | YES | YES | YES | YES |
| Surge protection SPD (DC/AC) | Type III / Type III | Type III / Type III | Type III / Type III | Type III / Type III | Type III / Type III | Type III / Type III | Type III / Type III | Type III / Type III |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
| AC auxiliary power supply (APS) | Optional | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
| STANDARDS | ||||||||
| Safety | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 |
| Electromagnetic compatibility (EMC) | IEC/EN 61000; NB/T 32004 | IEC/EN 61000; NB/T 32004 | IEC/EN 61000; NB/T 32004 | IEC/EN 61000; NB/T 32004 | IEC/EN 61000; NB/T 32004 | IEC/EN 61000; NB/T 32004 | IEC/EN 61000; NB/T 32004 | IEC/EN 61000; NB/T 32004 |
| Certification | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 |
Input 1 is optional with two strings (max. input current: 32 A, max. short-circuit current: 40 A).