Inverter – SOLAX – X3-MGA-50K-G2(L)
Product details
| Weight | 52,26 kg |
|---|---|
| CN | 85044086 |
Solax X3-MEGA G2
The three-phase on-grid inverter Solax X3-MEGA G2 is an advanced solution for harvesting solar energy with power ranging from 40 to 60 kW. The device features a high efficiency of up to 98.4% and a wide MPPT voltage range, ensuring optimal utilization of the photovoltaic installation. Thanks to innovative solutions, the inverter guarantees safety, reliability and ease of use.
Key features of the Solax X3-MEGA G2:
- Maximum efficiency of 98.4% for effective energy conversion.
- Wide MPPT voltage range 180-1000 V DC with support for up to 6 MPPTs and 2 strings per tracker.
- 150% PV input oversizing and 110% output overload increase installation flexibility.
- Ingress protection IP66 and built-in SPD (type II) protection on both AC and DC sides enhance safety.
- Optional AFCI protection and advanced monitoring features, including Smart I-V Curve Diagnosis.
- Intelligent air cooling and advanced thermal management technology extend lifespan and reduce device dimensions.
Who is this a good choice for?
The Solax X3-MEGA G2 inverter is an ideal solution for medium and large photovoltaic installations, both commercial and industrial. It is suitable for systems requiring high performance, reliability and advanced monitoring and safety features. The ability to oversize the input and the IP66 rating make it suitable for use in more demanding conditions.
| Parameter | X3-MGA-40K-G2 | X3-MGA-50K-G2 | X3-MGA-60K-G2 |
|---|---|---|---|
| DC INPUT | |||
| Max. PV input power [kWp] | 60 | 75 | 90 |
| Max. PV input voltage [V] | 1100 | 1100 | 1100 |
| Start-up voltage [V] | 200 | 200 | 200 |
| Nominal input voltage [V] | 600 | 600 | 600 |
| MPPT tracker voltage range [V] | 180-1000 | 180-1000 | 180-1000 |
| Number of MPPT trackers | 4 | 5 | 6 |
| Strings per MPPT tracker | 2 | 2 | 2 |
| Max. PV input current per MPPT [A] | 32 | 32 | 32 |
| Isc PV Array Short-circuit current per MPPT [A] | 46 | 46 | 46 |
| AC OUTPUT | |||
| Rated AC output power [KW] | 40 | 50 | 60 |
| Rated AC output current [A] | 60,6/58 | 75,8/72,5 | 90,9/87 |
| Max. AC apparent output power [KVA] | 44 | 55 | 66 |
| Max. AC output current [A] | 66,7/63,8 | 83,3/79,7 | 100/95,7 |
| Nominal AC voltage [V] | 220/380 V, 230/400 V, 3/N/PE, 3/PE | 220/380 V, 230/400 V, 3/N/PE, 3/PE | 220/380 V, 230/400 V, 3/N/PE, 3/PE |
| AC voltage range [V] | 304-460 | 304-460 | 304-460 |
| Nominal AC frequency / AC frequency range [Hz] | 50/60; +5 | 50/60; +5 | 50/60; +5 |
| Power factor range | Leading 0.8 / Lagging 0.8 | Leading 0.8 / Lagging 0.8 | Leading 0.8 / Lagging 0.8 |
| THDi (rated power) [%] | <3 | <3 | <3 |
| SYSTEM DATA | |||
| Max. efficiency [%] | 98,4 | 98,4 | 98,4 |
| European efficiency [%] | 98,1 | 98,1 | 98,1 |
| Standby power consumption [W] at night | <2 | <2 | <2 |
| Ingress protection | IP66 | IP66 | IP66 |
| Operating ambient temperature range [°C] | -30~+60 (derating above 45) | -30~+60 (derating above 45) | -30~+60 (derating above 45) |
| Max. operating altitude [m] | 4000 (derating above 3000) | 4000 (derating above 3000) | 4000 (derating above 3000) |
| Relative humidity [%] | 0-100 | 0-100 | 0-100 |
| Dimensions (W x H x D) [mm] | 630 x 521 x 286 | 630 x 521 x 286 | 630 x 521 x 286 |
| Weight [kg] | 44 | 44,5 | 45,5 |
| Cooling method | Intelligent fan cooling | Intelligent fan cooling | Intelligent fan cooling |
| Communication interfaces | RS485/USB/DRM/PLC (optional) | RS485/USB/DRM/PLC (optional) | RS485/USB/DRM/PLC (optional) |
| Optional monitoring hardware key | Pocket WiFi/LAN/4G | Pocket WiFi/LAN/4G | Pocket WiFi/LAN/4G |
| Display | LCD (16×2, optional)/LEDX4 | LCD (16×2, optional)/LEDX4 | LCD (16×2, optional)/LEDX4 |
| PROTECTIONS | |||
| Over/under voltage protection | YES | YES | YES |
| Overcurrent protection | YES | YES | YES |
| DC isolation protection | YES | YES | YES |
| Grid monitoring | YES | YES | YES |
| DC pulse monitoring | YES | YES | YES |
| Residual current detection | YES | YES | YES |
| Anti-islanding protection | YES | YES | YES |
| String fault detection | YES | YES | YES |
| Over-temperature protection | YES | YES | YES |
| AC auxiliary power (APS) | YES | YES | YES |
| Power line communication (PLC) | Optional | Optional | Optional |
| SPD (DC/AC) | Type II/type II | Type II/type II | Type II/type II |
| Arc fault circuit interrupter (AFCI) | YES | YES | YES |
| STANDARDS | |||
| Safety | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 |
| EMC | EN/IEC 61000; NB/T 32004 | EN/IEC 61000; NB/T 32004 | EN/IEC 61000; NB/T 32004 |
| Certifications | VDE4105; EN 50549; AS 4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 | VDE4105; EN 50549; AS 4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 |
*The two values refer to different grid voltages 220 V/230 V. **AC voltage and frequency range may vary depending on different national regulations. Information is subject to change without notice.