Inverter DEYE SUN-10K-SG01HP3-EU-AM2
SKU: F20GZ7
EAN: 5905951584201
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 2 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
CAN | Yes |
SPD Type II | |
SPD Type I+II | |
Weight | 39,5 kg |
CN | 85044086 |
Manual Deye SUN-10K-SG01HP3-EU-AM2
manual-deye-sun-10k-sg01hp3-eu-am2.pdf
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 2 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
CAN | Yes |
SPD Type II | |
SPD Type I+II | |
Weight | 39,5 kg |
CN | 85044086 |
Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 Hybrid Three-Phase Inverter
The Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 series of hybrid inverters are advanced solutions for large photovoltaic systems. With the ability to handle high-voltage batteries, operate in both on-grid and off-grid modes, and offer flexible configuration options, these inverters meet the needs of the most demanding users.
Main Features of Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 Inverters:
- 100% Unbalanced Power – each phase can operate at full unbalanced power, ensuring the stability and reliability of the system.
- Upgrade Capability for Existing Systems – AC coupling allows for easy upgrades of solar systems.
- Support for Multiple Batteries – the ability to connect up to 10 devices in parallel for both on-grid and off-grid operation, providing great flexibility in configuration.
- Maximum Charging/Discharging Current of 50A – enhanced energy efficiency in energy storage processes.
- High-Voltage Batteries – ensure higher efficiency and reduced energy losses in the system.
- 6 Charging/Discharging Periods for Batteries – flexible energy management tailored to user needs.
- Support for Diesel Generators – the ability to store energy from a generator increases energy independence.
Who is This a Good Choice For?
The Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 inverters are an ideal solution for large industrial and commercial installations. With high-voltage support, reliability, and flexible configuration options, they are an excellent choice for users seeking advanced energy management and high efficiency.
Manual Deye SUN-10K-SG01HP3-EU-AM2
manual-deye-sun-10k-sg01hp3-eu-am2.pdf
Product Specifications | ||||||||
---|---|---|---|---|---|---|---|---|
Model | SUN-5K-SG01 HP3-EU-AM2 | SUN-6K-SG01 HP3-EU-AM2 | SUN-8K-SG01 HP3-EU-AM2 | SUN-10K-SG01 HP3-EU-AM2 | SUN-12K-SG01 HP3-EU-AM2 | SUN-15K-SG01 HP3-EU-AM2 | SUN-20K-SG01 HP3-EU-AM2 | SUN-25K-SG01 HP3-EU-AM2 |
Battery Input Data | ||||||||
Battery Type | Lithium-ion | Lithium-ion | Lithium-ion | Lithium-ion | Lithium-ion | Lithium-ion | Lithium-ion | Lithium-ion |
Battery Voltage Range (V) | 160-700 | 160-700 | 160-700 | 160-700 | 160-700 | 160-700 | 160-700 | 160-700 |
Max Charging Current (A) | 30 | 30 | 37 | 37 | 37 | 37 | 37 | 50 |
Max Discharging Current (A) | 30 | 30 | 37 | 37 | 37 | 37 | 37 | 50 |
Charging Strategy for Li-ion Batteries | Compatible with BMS | Compatible with BMS | Compatible with BMS | Compatible with BMS | Compatible with BMS | Compatible with BMS | Compatible with BMS | Compatible with BMS |
Number of Battery Inputs | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
PV Input/Output Data | ||||||||
Max PV Input Power (W) | 6500 | 7800 | 10400 | 13000 | 15600 | 19500 | 26000 | 32500 |
Max PV Input Voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Starting Voltage (V) | 180 | 180 | 180 | 180 | 180 | 180 | 180 | 180 |
MPPT Voltage Range (V) | 150-850 | 150-850 | 150-850 | 150-850 | 150-850 | 150-850 | 150-850 | 150-850 |
DC Voltage Range at Full Load (V) | 195-850 | 195-850 | 260-850 | 325-850 | 340-850 | 420-850 | 500-850 | 625-850 |
Nominal PV Input Voltage (V) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
Max PV Input Current (A) | 20+20 | 20+20 | 20+20 | 20+20 | 26+20 | 26+20 | 26+26 | 26+26 |
Max PV Short-Circuit Current (A) | 30+30 | 30+30 | 30+30 | 30+30 | 39+30 | 39+30 | 39+39 | 39+39 |
Number of MPPT Trackers | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Number of Strings per MPPT Tracker | 1+1 | 1+1 | 1+1 | 1+1 | 2+1 | 2+1 | 2+2 | 2+2 |
AC Output Data | ||||||||
Rated AC Input/Output Power (W) | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | 25000 |
Max AC Apparent Input/Output Power (VA) | 5500 | 6600 | 8800 | 11000 | 13200 | 16500 | 22000 | 27500 |
Rated AC Input/Output Current (A) | 7.6/7.3 | 9.1/8.7 | 12.2/11.6 | 15.2/14.5 | 18.2/17.4 | 22.8/21.8 | 30.4/29 | 37.9/36.3 |
Max AC Input/Output Current (A) | 8.4/8 | 10/9.6 | 13.4/12.8 | 16.7/16 | 20/19.2 | 25/24 | 33.4/31.9 | 41.7/39.9 |
Max Continuous AC Redirect (from grid to load) (A) | 40 | 40 | 40 | 40 | 80 | 80 | 80 | 80 |
Peak Power (off-grid) (W) | 1.5 x rated power, for 10s | 1.5 x rated power, for 10s | 1.5 x rated power, for 10s | 1.5 x rated power, for 10s | 1.5 x rated power, for 10s | 1.5 x rated power, for 10s | 1.5 x rated power, for 10s | 1.5 x rated power, for 10s |
Generator Input / Smart Load Current (A) | 7.6/40/7.6 | 9.1/40/9.1 | 12.2/40/12.2 | 15.2/40/15.2 | 18.2/80/18.2 | 22.8/80/22.8 | 30.4/80/30.4 | 37.9/80/37.9 |
Power Factor Regulation Range | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
Nominal Frequency and Power of the Grid (Hz) (V) | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | 50/60Hz; 3L/N/PE 220/380, 230/400Vac |
Connection Form to the Grid | 3 phases | 3 phases | 3 phases | 3 phases | 3 phases | 3 phases | 3 phases | 3 phases |
Total Harmonic Distortion Current (THDi) | <3% (rated power) | <3% (rated power) | <3% (rated power) | <3% (rated power) | <3% (rated power) | <3% (rated power) | <3% (rated power) | <3% (rated power) |
DC Injection Current | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In |
Efficiency | ||||||||
Max Efficiency | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% |
European Efficiency | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% |
MPPT Efficiency | >99% | >99% | >99% | >99% | >99% | >99% | >99% | >99% |
Device Protection | ||||||||
Integrated Protection | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level | DC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level |
Surge Protection Level | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) |
Certifications and Standards | ||||||||
Grid Regulations | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
General Data | ||||||||
Operating Temperature Range (°C) | -40 to +60°C, >45°C power limitation | -40 to +60°C, >45°C power limitation | -40 to +60°C, >45°C power limitation | -40 to +60°C, >45°C power limitation | -40 to +60°C, >45°C power limitation | -40 to +60°C, >45°C power limitation | -40 to +60°C, >45°C power limitation | -40 to +60°C, >45°C power limitation |
Cooling Type | Natural cooling | Natural cooling | Smart air cooling | Smart air cooling | Smart air cooling | Smart air cooling | Smart air cooling | Smart air cooling |
Noise (dB) | ≤55 | ≤55 | ≤55 | ≤55 | ≤55 | ≤55 | ≤55 | ≤55 |
Communication with BMS | CAN | CAN | CAN | CAN | CAN | CAN | CAN | CAN |
Weight (kg) | 30.5 | 30.5 | 30.5 | 30.5 | 30.5 | 30.5 | 30.5 | 30.5 |
Dimensions (HxWxD mm) | 408×638×237 (excluding connectors and handles) | 408×638×237 (excluding connectors and handles) | 408×638×237 (excluding connectors and handles) | 408×638×237 (excluding connectors and handles) | 408×638×237 (excluding connectors and handles) | 408×638×237 (excluding connectors and handles) | 408×638×237 (excluding connectors and handles) | 408×638×237 (excluding connectors and handles) |
IP Protection Class | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 |
Mounting Method | Wall mounting | Wall mounting | Wall mounting | Wall mounting | Wall mounting | Wall mounting | Wall mounting | Wall mounting |
Warranty | 5 years/10 years (Optional) | 5 years/10 years (Optional) | 5 years/10 years (Optional) | 5 years/10 years (Optional) | 5 years/10 years (Optional) | 5 years/10 years (Optional) | 5 years/10 years (Optional) | 5 years/10 years (Optional) |