Inverter DEYE SUN-20K-SG01HP3-EU-AM2

SKU: F20GZB EAN: 5905951584232
Manufacturer

Rated power

Power supply

Hybrid device

MPPT

2

AFCI

Optional

Warranty

Net width

Net depth

Net height

CAN

Yes

SPD Type II

SPD Type I+II

Weight41 kg
CN85044086

2 456,36 
Gross

Login to place an order

Manual Deye SUN-20K-SG01HP3-EU-AM2 manual-deye-sun-20k-sg01hp3-eu-am2.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

MPPT

2

AFCI

Optional

Warranty

Net width

Net depth

Net height

CAN

Yes

SPD Type II

SPD Type I+II

Weight41 kg
CN85044086

Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 Hybrid Inverter

The Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 series of hybrid inverters offers advanced solutions for large photovoltaic systems. With the capability to support high-voltage batteries, operate in both on-grid and off-grid modes, and flexible configuration options, these inverters meet the needs of even the most demanding users.

Key Features of the Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 Inverters:

  • 100% Unbalanced Power – each phase can operate at full unbalanced power, ensuring stability and reliability of the system.
  • Upgrade Existing Systems – AC coupling allows for easy upgrades to solar systems.
  • Support for Multiple Batteries – ability to connect up to 10 devices in parallel for both on-grid and off-grid operation, providing great flexibility in configuration.
  • Maximum Charging/Discharging Current 50A – enhanced energy efficiency in energy storage processes.
  • High-Voltage Batteries – offer higher efficiency and reduced energy losses in the system.
  • 6 Charging/Discharging Periods – flexible energy management tailored to user needs.
  • Support for Diesel Generators – energy storage from the generator increases energy independence.

Who is it a Good Choice For?

The Deye SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 inverters are an ideal solution for large industrial and commercial installations. With high-voltage support, reliability, and flexible configuration options, they are an excellent choice for users seeking advanced energy management and high efficiency.

Manual Deye SUN-20K-SG01HP3-EU-AM2 manual-deye-sun-20k-sg01hp3-eu-am2.pdf

Product Specifications
ModelSUN-5K-SG01 HP3-EU-AM2SUN-6K-SG01 HP3-EU-AM2SUN-8K-SG01 HP3-EU-AM2SUN-10K-SG01 HP3-EU-AM2SUN-12K-SG01 HP3-EU-AM2SUN-15K-SG01 HP3-EU-AM2SUN-20K-SG01 HP3-EU-AM2SUN-25K-SG01 HP3-EU-AM2
Battery Input Data
Battery TypeLithium-ionLithium-ionLithium-ionLithium-ionLithium-ionLithium-ionLithium-ionLithium-ion
Battery Voltage Range (V)160-700160-700160-700160-700160-700160-700160-700160-700
Max Charging Current (A)3030373737373750
Max Discharging Current (A)3030373737373750
Charging Strategy for Li-ion BatteriesCompatible with BMSCompatible with BMSCompatible with BMSCompatible with BMSCompatible with BMSCompatible with BMSCompatible with BMSCompatible with BMS
Number of Battery Inputs11111111
PV Input/Output Data
Max PV Input Power (W)65007800104001300015600195002600032500
Max PV Input Voltage (V)10001000100010001000100010001000
Starting Voltage (V)180180180180180180180180
MPPT Voltage Range (V)150-850150-850150-850150-850150-850150-850150-850150-850
DC Voltage Range at Full Load (V)195-850195-850260-850325-850340-850420-850500-850625-850
Nominal PV Input Voltage (V)600600600600600600600600
Max PV Input Current (A)20+2020+2020+2020+2026+2026+2026+2626+26
Max PV Short-Circuit Current (A)30+3030+3030+3030+3039+3039+3039+3939+39
Number of MPPT Trackers22222222
Number of Strings per MPPT Tracker1+11+11+11+12+12+12+22+2
AC Output Data
Rated AC Input/Output Power (W)5000600080001000012000150002000025000
Max AC Apparent Input/Output Power (VA)5500660088001100013200165002200027500
Rated AC Input/Output Current (A)7.6/7.39.1/8.712.2/11.615.2/14.518.2/17.422.8/21.830.4/2937.9/36.3
Max AC Input/Output Current (A)8.4/810/9.613.4/12.816.7/1620/19.225/2433.4/31.941.7/39.9
Max Continuous AC Redirect (from grid to load) (A)4040404080808080
Peak Power (off-grid) (W)1.5 x rated power, for 10s1.5 x rated power, for 10s1.5 x rated power, for 10s1.5 x rated power, for 10s1.5 x rated power, for 10s1.5 x rated power, for 10s1.5 x rated power, for 10s1.5 x rated power, for 10s
Generator Input / Smart Load Current (A)7.6/40/7.69.1/40/9.112.2/40/12.215.2/40/15.218.2/80/18.222.8/80/22.830.4/80/30.437.9/80/37.9
Power Factor Regulation Range0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging
Nominal Frequency and Power of the Grid (Hz) (V)50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac50/60Hz; 3L/N/PE 220/380, 230/400Vac
Connection Method to the Grid3 phases3 phases3 phases3 phases3 phases3 phases3 phases3 phases
Total Harmonic Distortion Current (THDi)<3% (rated power)<3% (rated power)<3% (rated power)<3% (rated power)<3% (rated power)<3% (rated power)<3% (rated power)<3% (rated power)
DC Injection Current<0.5% In<0.5% In<0.5% In<0.5% In<0.5% In<0.5% In<0.5% In<0.5% In
Efficiency
Max Efficiency97.6%97.6%97.6%97.6%97.6%97.6%97.6%97.6%
European Efficiency97.0%97.0%97.0%97.0%97.0%97.0%97.0%97.0%
MPPT Efficiency>99%>99%>99%>99%>99%>99%>99%>99%
Device Protection
Integrated ProtectionDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection levelDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection levelDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection levelDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection levelDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection levelDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection levelDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection levelDC reverse polarity protection, AC overcurrent protection, AC surge protection, AC output short circuit protection, thermal protection, DC insulation impedance monitoring, DC component monitoring, ground leakage current monitoring, grid monitoring, island protection, ground detection, DC input switch, load switch surge protection, residual current detection (RCD), surge protection level
Surge Protection LevelType II (DC), Type II (AC)Type II (DC), Type II (AC)Type II (DC), Type II (AC)Type II (DC), Type II (AC)Type II (DC), Type II (AC)Type II (DC), Type II (AC)Type II (DC), Type II (AC)Type II (DC), Type II (AC)
Certifications and Standards
Grid RegulationsIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC StandardsIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (°C)-40 to +60°C, >45°C power limitation-40 to +60°C, >45°C power limitation-40 to +60°C, >45°C power limitation-40 to +60°C, >45°C power limitation-40 to +60°C, >45°C power limitation-40 to +60°C, >45°C power limitation-40 to +60°C, >45°C power limitation-40 to +60°C, >45°C power limitation
Cooling TypeNatural coolingNatural coolingIntelligent air coolingIntelligent air coolingIntelligent air coolingIntelligent air coolingIntelligent air coolingIntelligent air cooling
Noise (dB)≤55≤55≤55≤55≤55≤55≤55≤55
Communication with BMSCANCANCANCANCANCANCANCAN
Weight (kg)30.530.530.530.530.530.530.530.5
Dimensions (HxWxD mm)408×638×237 (excluding connectors and handles)408×638×237 (excluding connectors and handles)408×638×237 (excluding connectors and handles)408×638×237 (excluding connectors and handles)408×638×237 (excluding connectors and handles)408×638×237 (excluding connectors and handles)408×638×237 (excluding connectors and handles)408×638×237 (excluding connectors and handles)
IP Protection ClassIP 65IP 65IP 65IP 65IP 65IP 65IP 65IP 65
Mounting MethodWall mountingWall mountingWall mountingWall mountingWall mountingWall mountingWall mountingWall mounting
Warranty5 years/10 years (Optional)5 years/10 years (Optional)5 years/10 years (Optional)5 years/10 years (Optional)5 years/10 years (Optional)5 years/10 years (Optional)5 years/10 years (Optional)5 years/10 years (Optional)

Official distribution

Other brands in our portfolio