Inverter FoxESS H3-8.0-E Hybrid
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 2 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
DRM | Yes |
Ethernet | Yes |
GSM | Optional |
RS485 | Yes |
USB | Yes |
Wi-Fi | Yes |
SPD Type II | |
Weight | 33,98 kg |
CN | 85044086 |
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 2 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
DRM | Yes |
Ethernet | Yes |
GSM | Optional |
RS485 | Yes |
USB | Yes |
Wi-Fi | Yes |
SPD Type II | |
Weight | 33,98 kg |
CN | 85044086 |
FoxESS H3-5.0 -12.0 AC3-5.0 -10.0 – Three-Phase Hybrid Inverter
The FoxESS H3-5.0 -10.0 AC3 is an advanced three-phase hybrid inverter designed for maximizing solar energy usage both during the day and at night. With the capability to integrate with FoxESS batteries, this device provides a flexible and efficient energy management solution for a variety of installation environments.
Key Product Features
- Easy Installation: Flexible configuration and readiness for installation ensure straightforward system expansion.
- High-Performance Batteries: Capability to create a setup that works with high-performance FoxESS batteries for optimal synergy.
- IP65 Rating: Designed to withstand harsh weather conditions, making it ideal for both indoor and outdoor installations.
- Remote Monitoring: Real-time device monitoring through a website or mobile app.
- Easy Expansion: Option to add additional batteries, increasing the system capacity up to 20.8 kWh.
Who is it a Good Choice For?
The FoxESS H3-5.0 -12.0 AC3-5.0 -10.0 is an ideal solution for homeowners and businesses looking for a reliable energy management system with battery integration. With advanced features such as remote monitoring, flexible configuration, and resilience to challenging conditions, this product meets the expectations of the most demanding users.
PV Input (for hybrid devices only) | ||||||
---|---|---|---|---|---|---|
Parameter | H3-5.0-E AC3-5.0-E | H3-6.0-E AC3-6.0-E | H3-8.0-E AC3-8.0-E | H3-10.0-E AC3-10.0-E | H3-12.0-E | |
Max. Input Power [W] | A: 4000 B: 4000 | A: 4000 B: 4000 | A: 8000 B: 5000 | A: 8000 B: 5000 | A: 9000 B: 6000 | |
Max. Input Voltage [V] | 1000 | 1000 | 1000 | 1000 | 1000 | |
Starting Voltage [V] | 160 | 160 | 160 | 160 | 160 | |
Nominal Input Voltage [V] | 720 | 720 | 720 | 720 | 720 | |
MPPT Voltage Range [V] | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 | |
Max. Input Current [A] | 14/14 | 14/14 | 26/14 | 26/14 | 26/14 | |
Max. Short Circuit Current [A] | 16/16 | 16/16 | 32/16 | 32/16 | 32/16 | |
Number of Independent MPPTs | 2 | 2 | 2 | 2 | 2 | |
Strings per MPPT | 1 | 1 | 2 | 2 | 2 | |
Battery | ||||||
Battery Type | Lithium Iron Phosphate (LFP) | Lithium Iron Phosphate (LFP) | Lithium Iron Phosphate (LFP) | Lithium Iron Phosphate (LFP) | Lithium Iron Phosphate (LFP) | |
Battery Voltage Range [V] | 180-600 | 180-600 | 180-600 | 180-600 | 180-600 | |
Max. Charge/Discharge Current [A] | 26.0 | 26.0 | 26.0 | 26.0 | 26.0 | |
Communication Interface | CAN (Communication with inverter), RS485 (BMS update) | CAN (Communication with inverter), RS485 (BMS update) | CAN (Communication with inverter), RS485 (BMS update) | CAN (Communication with inverter), RS485 (BMS update) | CAN (Communication with inverter), RS485 (BMS update) | |
AC Input and Output (Distribution Network) | ||||||
Max. AC Input Power [VA] | 10000 | 12000 | 16000 | 16000 | 16000 | |
Max. AC Input Current (per phase) [A] | 15.2 | 18.2 | 24.2 | 24.2 | 24.2 | |
Nominal Output Power [W] | 5000 | 6000 | 8000 | 10000 | 12000 | |
Max. Output Apparent Power [VA] | 5500 | 6600 | 8800 | 11000 | 13200 | |
Nominal Output Current (per phase) [A] | 7.2 | 8.7 | 11.6 | 14.5 | 17.4 | |
Max. Output Current (per phase) [A] | 8.8 | 10.6 | 14.1 | 17.4 | 21.2 | |
Nominal Grid Voltage [V] | 3L/N/PE 380/220; 400/230; 415/240 | 3L/N/PE 380/220; 400/230; 415/240 | 3L/N/PE 380/220; 400/230; 415/240 | 3L/N/PE 380/220; 400/230; 415/240 | 3L/N/PE 380/220; 400/230; 415/240 | |
Nominal Grid Frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | |
Power Factor | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | |
THDi (Linear Load) | <3%@Nominal Power | <3%@Nominal Power | <3%@Nominal Power | <3%@Nominal Power | <3%@Nominal Power | |
EPS | ||||||
Max. Apparent Power [VA] | 5000 | 6000 | 8000 | 10000 | 12000 | |
Peak Apparent Power (60s) [VA] | 10000 | 12000 | 14000 | 15000 | 15000 | |
Max. Output Current (per phase) [A] | 7.2 | 8.7 | 11.6 | 14.5 | 17.4 | |
Nominal Output Voltage [V] | 3L/N/PE 400/230 | 3L/N/PE 400/230 | 3L/N/PE 400/230 | 3L/N/PE 400/230 | 3L/N/PE 400/230 | |
Nominal Output Frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | |
Power Factor | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | 1 (Adjustable from 0.8 leading to 0.8 lagging) | |
THDv (Linear Load) | <3%@Nominal Power | <3%@Nominal Power | <3%@Nominal Power | <3%@Nominal Power | <3%@Nominal Power | |
Switching Time [ms] | <20 | <20 | <20 | <20 | <20 | |
Efficiency | ||||||
Max. Efficiency | 98.00% | 98.00% | 98.00% | 98.00% | 98.00% | |
European Efficiency | 97.30% | 97.30% | 97.30% | 97.30% | 97.30% | |
Max. Battery Charging Efficiency (PV to BAT) (@full load) | 98.50% | 98.50% | 98.50% | 98.50% | 98.50% | |
Max. Battery Discharging Efficiency (BAT to AC) (@full load) | 97.00% | 97.00% | 97.00% | 97.00% | 97.00% | |
Protections | ||||||
Insulation Monitoring | Yes | Yes | Yes | Yes | Yes | |
Residual Current Protection | Yes | Yes | Yes | Yes | Yes | |
DC Reverse Polarity Protection | Yes | Yes | Yes | Yes | Yes | |
Island Operation Protection | Yes | Yes | Yes | Yes | Yes | |
AC Short-Circuit Protection | Yes | Yes | Yes | Yes | Yes | |
Overcurrent/Overvoltage Protection for AC | Yes | Yes | Yes | Yes | Yes | |
DC Disconnect | Yes | Yes | Yes | Yes | Yes | |
Surge Protection | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | |
General Information | ||||||
Dimensions (HxWxD) [mm] | 449 × 519 × 198 | 449 × 519 × 198 | 449 × 519 × 198 | 449 × 519 × 198 | 449 × 519 × 198 | |
Weight [kg] | 28 | 28 | 28 | 28 | 28 | |
Inverter Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | |
Cooling | Natural/Convective | Natural/Convective | Natural/Convective | Natural with additional fan | Natural with additional fan | |
Noise Emission [dB] | 35 | 35 | 35 | 45 | 45 | |
Max. Mounting Height [m] | 2000 | 2000 | 2000 | 2000 | 2000 | |
Operating Temperature Range [°C] | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | |
Humidity (Non-condensing) | 0%-100% | 0%-100% | 0%-100% | 0%-100% | 0%-100% | |
Protection Rating | IP65 | IP65 | IP65 | IP65 | IP65 | |
Power Consumption [W] | <15 | <15 | <15 | <15 | <15 | |
Monitoring and Communication | ||||||
Monitoring | WiFi, ETH, GSM (in development) | WiFi, ETH, GSM (in development) | WiFi, ETH, GSM (in development) | WiFi, ETH, GSM (in development) | WiFi, ETH, GSM (in development) | |
Communication | 2xRS485, DRM, USB | 2xRS485, DRM, USB | 2xRS485, DRM, USB | 2xRS485, DRM, USB | 2xRS485, DRM, USB | |
Display | LCD, Mobile App, Web | LCD, Mobile App, Web | LCD, Mobile App, Web | LCD, Mobile App, Web | LCD, Mobile App, Web | |
Certifications | ||||||
Safety Standards | EN 62109-1, EN 62109-2, EN 62477-1 | EN 62109-1, EN 62109-2, EN 62477-1 | EN 62109-1, EN 62109-2, EN 62477-1 | EN 62109-1, EN 62109-2, EN 62477-1 | EN 62109-1, EN 62109-2, EN 62477-1 | |
Electromagnetic Compatibility | IEC 61000-6-1, IEC 61000-6-3 | IEC 61000-6-1, IEC 61000-6-3 | IEC 61000-6-1, IEC 61000-6-3 | IEC 61000-6-1, IEC 61000-6-3 | IEC 61000-6-1, IEC 61000-6-3 | |
Current Standards | EN 50549-1, C10/11, VDE-AR-N 4105, G98, CEI 0-21 | EN 50549-1, C10/11, VDE-AR-N 4105, G98, CEI 0-21 | EN 50549-1, C10/11, VDE-AR-N 4105, G98, CEI 0-21 | EN 50549-1, C10/11, VDE-AR-N 4105, G98, CEI 0-21 | EN 50549-1, C10/11, VDE-AR-N 4105, G98, CEI 0-21 |