GEN24 SC
GEN24 SC by Fronius is a series of three-phase photovoltaic inverters with a rated AC power of 3–12 kW, depending on the model. The integrated PV Point function provides basic backup power, while open interfaces enable integration with components from Fronius and other manufacturers. Energy management functions and active cooling support system operation and extend the inverter’s service life.
Key advantages of GEN24 SC
- Basic backup power supply PV Point: rated output power of 3000 VA and a switchover time of approximately 15 seconds.
- Two maximum power point trackers: usable MPP voltage range of 80–800 V and DC input voltage range of 80–1000 V.
- Maximum efficiency 98.1–98.3%: value depends on the model in the series.
- Communication and energy management: WLAN, two Ethernet LAN ports, two RS485 interfaces and an integrated data logger and web server.
- Active cooling: a solution that extends the inverter’s lifespan.
- IP66 protection rating: suitable for indoor and outdoor installation and an ambient temperature range from −25 to +60°C.
Who is this a good choice for?
GEN24 SC is designed for homeowners with photovoltaic systems who need basic PV Point backup power and energy management functions. For users who want to combine Fronius components with devices from other manufacturers, it offers open interfaces and access to data via Fronius Solar.web.
| Parameter | Symo GEN24 10.0 Plus SC |
|---|---|
| Number of MPPT trackers | 2 |
| DC input voltage range (V) | 80 – 1,000 |
| Rated input voltage (V) | 610 |
| Grid feed-in start voltage (V) | 80 |
| Usable MPP voltage range (V) | 80 – 800 |
| MPP voltage range at rated power (V) | 246 – 800 |
| Maximum total usable DC power (W) | 10,300 |
| Maximum total PV generator power (Wp) | 15,000 |
| Maximum usable input current MPPT 1 (A) | 28 |
| Maximum PV generator short-circuit current MPPT 1 (A) | 40 |
| Number of DC connections MPPT 1 | 2 |
| Maximum usable DC power MPPT 1 (W) | 10,300 |
| Maximum PV generator power MPPT 1 (Wp) | 12,000 |
| Maximum usable input current MPPT 2 (A) | 14 |
| Maximum PV generator short-circuit current MPPT 2 (A) | 20 |
| Number of DC MPPT connections 2 | 1 |
| Maximum usable DC power MPPT 2 (W) | 10,300 |
| Maximum PV generator power MPPT 2 (Wp) | 12,000 |
| Rated AC active power (W) | 10,000 |
| Apparent power (VA) | 10,000 |
| Maximum output power (VA) | 10,000 |
| Rated AC output current at 380 V (A) | 15,2 |
| Rated AC output current at 400 V (A) | 14,5 |
| Grid connection (V) | 3~ NPE 400/230 or 3~ NPE 380/220 (+20%/-30%) |
| Rated frequency and frequency range (Hz) | 50/60 (45 – 65) |
| Total harmonic distortion (%) | < 3,5 |
| Power factor cos φ | 0.7 – 1 ind. / cap. |
| PV Point rated output power (VA) | 3,000 |
| PV Point connection (V) | 1~ NPE 220/230 |
| PV Point switchover time (s) | ~15 |
| Rated Full Backup output power (VA) | 10,000 |
| Rated single-phase Full Backup power (VA) | 4,225 |
| Full Backup connection (V) | 3~ NPE 400/230 or 3~ NPE 380/220 |
| Full Backup switchover time (s) | ~10 |
| Number of battery DC inputs | 1 |
| Maximum battery input current (A) | 22 |
| Battery input voltage range (V) | 160 – 700 |
| Battery DC terminals | 1x BATT+ and 1x BATT- push-in spring terminals 2.5 – 10 mm² |
| Maximum battery DC input/output power (W) | 10300 |
| Maximum AC-coupled charging power (W) | 10,000 |
| Compatible batteries | Fronius Reserva & BYD Battery-Box HVS/HVM, HVS+/HVM+ & LG FLEX |
| Maximum efficiency (%) | 98,3 |
| European efficiency (%) | 98,1 |
| MPP tracking efficiency (%) | > 99,9 |
| Nighttime power consumption (W) | <10 |
| Dimensions: height × width × depth (mm) | 595 × 529 × 180 |
| Inverter weight (kg) | 22.8 |
| Degree of protection | IP 66 |
| Protection class | 1 |
| DC/AC overvoltage category | 2/3 |
| Cooling | Active Cooling technology |
| Installation location | Indoor and outdoor installation |
| Ambient temperature (°C) | -25 to +60 |
| Permissible humidity (%) | 0 – 100 |
| Noise emission (dB(A)) | < 47 |
| Maximum altitude above sea level (m) | 3,000/4,000 (unrestricted/restricted voltage range) |
| PV installation DC terminals | 3 × DC+ and 3 × DC- push-in spring terminals 2.5 – 10 mm² |
| AC terminals | 5-pin AC push-in spring terminals 1.5 – 10 mm² |
| Backup power terminals | 3-pin backup power push-in spring terminals 1.5–10 mm² |
| PPE clamps | 5 × PPE screw terminals 2.5 – 16 mm² |
| Backup power functions | PV Point (Comfort) or Full Backup |
| DC insulation measurement | Integrated |
| DC disconnector | Integrated |
| Reverse polarity protection | Integrated |
| Arc fault detection | Integrated, Arc Guard Technology |
| WSD emergency shutdown | Integrated |
| WLAN / 2 × Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
| 6 digital inputs | Connection to ripple control receiver, energy management |
| 6 digital inputs/outputs | Connection to ripple control receiver, energy management |
| Data logger and web server | Integrated |
| 2 × RS485 | Modbus RTU SunSpec (third-party provider)/Fronius Smart Meter, battery, Fronius Ohmpilot |
| Certificates and compliance with standards | IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G 98, R25 |
| Country of manufacture | Austria |
| Life cycle analysis | In accordance with ÖNORM EN ISO 14040 and 14044 (checked by employees from Fraunhofer IZM) |
The battery connection applies only to Plus SC; Full Backup is available only in Plus SC 6.0–12.0 and requires external switching components. Battery power and compatibility depend on its type as well as availability and country-specific certification.