Inverter SOFAR 30 KTLX – G3
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 3 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
Bluetooth | Yes |
Ethernet | Optional |
RS485 | Yes |
Wi-Fi | Optional |
SPD Type II | |
Weight | 40,5 kg |
CN | 85044086 |
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 3 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
Bluetooth | Yes |
Ethernet | Optional |
RS485 | Yes |
Wi-Fi | Optional |
SPD Type II | |
Weight | 40,5 kg |
CN | 85044086 |
Sofar 25~50KTLX-G3 – Three-Phase Inverter with Advanced MPPT Technology
The Sofar 25~50KTLX-G3 is a high-performance three-phase inverter designed for large photovoltaic installations. With a maximum efficiency of up to 98.90%, this device guarantees high energy efficiency. Equipped with 3–4 MPPT, it offers flexible configuration and exceptional reliability, adapting to the needs of even the most demanding users.
Key Product Features
- Up to 4 MPPT: With a DC overload capability of up to 150% for optimal energy management.
- Type II SPD Relay: Provides protection on both the DC and AC sides.
- Low Start-up Voltage: Wide MPPT voltage range for better performance in low sunlight conditions.
- I-V Curve Scanning Function: Precise diagnostics and optimization of the system’s operation.
- Maximum Efficiency: Up to 98.90%, translating to effective system performance.
Who Is This an Ideal Choice For?
The Sofar 25~50KTLX-G3 is the perfect solution for large commercial and industrial installations where performance, reliability, and flexible configuration are crucial. With advanced features such as multiple MPPT, a wide voltage range, and intelligent monitoring, this inverter is suitable for both new projects and the modernization of existing photovoltaic systems. It’s an excellent choice for those who value modern technology and maximizing solar energy utilization.
Communication Module – Specification
SOFAR 25KTLX-G3 | SOFAR 30KTLX-G3 | SOFAR 33KTLX-G3 | SOFAR 36KTLX-G3 | SOFAR 40KTLX-G3 | SOFAR 45KTLX-G3 | SOFAR 50KTLX-G3 | ||
---|---|---|---|---|---|---|---|---|
DC Input | ||||||||
Recommended Max. PV Input Power (Wp) | 37500 | 45000 | 49500 | 54000 | 60000 | 67500 | 75000 | |
Max. DC Power for Single MPPT (W) | 25000 | 25000 | 25000 | 25000 | 25000 | 25000 | 25000 | |
Number of MPP Trackers | 3 | 3 | 3 | 3 | 4 | 4 | 4 | |
Number of DC Inputs | 2 for each MPPT | 2 for each MPPT | 2 for each MPPT | 2 for each MPPT | 2 for each MPPT | 2 for each MPPT | 2 for each MPPT | |
Max. Input Voltage (V) | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |
Startup Voltage (V) | 200 | 200 | 200 | 200 | 200 | 200 | 200 | |
Rated Input Voltage (V) | 620 | 620 | 620 | 620 | 620 | 620 | 620 | |
Operating MPPT Voltage Range (V) | 180-1000 | 180-1000 | 180-1000 | 180-1000 | 180-1000 | 180-1000 | 180-1000 | |
MPPT Full Power Voltage Range (V) | 480-850 | 480-850 | 510-850 | 540-850 | 480-850 | 510-850 | 540-850 | |
Max. MPPT Input Current (A) | 3*40 | 3*40 | 3*40 | 3*40 | 4*40 | 4*40 | 4*40 | |
Max. Short-Circuit Input Current per MPPT (A) | 3*50 | 3*50 | 3*50 | 3*50 | 4*50 | 4*50 | 4*50 | |
AC Output | ||||||||
Rated Power (W) | 25000 | 30000 | 33000 | 36000 | 40000 | 45000 | 50000 | |
Max. AC Power (VA) | 28000 | 34000 | 37000 | 40000 | 44000 | 50000 | 55000 | |
Max. Output Current (A) | 42.4 | 51.5 | 56.0 | 60.6 | 66.7 | 75.8 | 83.3 | |
Nominal Grid Voltage | 3 / N / PE, 220 V / 380 Vac, 230 V / 400 Vac | 3 / N / PE, 220 V / 380 Vac, 230 V / 400 Vac | 3 / N / PE, 220 V / 380 Vac, 230 V / 400 Vac | 3 / N / PE, 220 V / 380 Vac, 230 V / 400 Vac | 3 / N / PE, 220 V / 380 Vac, 230 V / 400 Vac | 3 / N / PE, 220 V / 380 Vac, 230 V / 400 Vac | ||
Grid Voltage Range (Vac) | 310–480 Vac (according to local standards) | 310–480 Vac (according to local standards) | 310–480 Vac (according to local standards) | 310–480 Vac (according to local standards) | 310–480 Vac (according to local standards) | 310–480 Vac (according to local standards) | 310–480 Vac (according to local standards) | |
Nominal Frequency of the Grid | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | |
Grid Frequency Range (Hz) | 45 Hz–55 Hz / 54 Hz–66 Hz (according to local standards) | 45 Hz–55 Hz / 54 Hz–66 Hz (according to local standards) | 45 Hz–55 Hz / 54 Hz–66 Hz (according to local standards) | 45 Hz–55 Hz / 54 Hz–66 Hz (according to local standards) | 45 Hz–55 Hz / 54 Hz–66 Hz (according to local standards) | 45 Hz–55 Hz / 54 Hz–66 Hz (according to local standards) | 45 Hz–55 Hz / 54 Hz–66 Hz (according to local standards) | |
Active Power Control Range | 0–100% | 0–100% | 0–100% | 0–100% | 0–100% | 0–100% | 0–100% | |
THDi | < 3% | < 3% | < 3% | < 3% | < 3% | < 3% | < 3% | |
Power Factor | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | |
Efficiency | ||||||||
Max. Efficiency | 98.60% | 98.60% | 98.60% | 98.60% | 98.80% | 98.80% | 98.80% | |
European Weighted Efficiency | 98.20% | 98.20% | 98.20% | 98.20% | 98.20% | 98.20% | 98.20% | |
Protection | ||||||||
Protection Against DC Reverse Polarity | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Islanding Protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Residual Current Protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Grounding Detection Protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
PV Array Monitoring for Faults | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Energy Outflow Block | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
DC Circuit Breaker | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
SPD Input/Output | PV: Type II standard, AC: Type II standard | PV: Type II standard, AC: Type II standard | PV: Type II standard, AC: Type II standard | PV: Type II standard, AC: Type II standard | PV: Type II standard, AC: Type II standard | PV: Type II standard, AC: Type II standard | PV: Type II standard, AC: Type II standard | |
Communication | ||||||||
Standard Communication Mode | RS485 / Bluetooth / WiFi / Optional: Ethernet | RS485 / Bluetooth / WiFi / Optional: Ethernet | RS485 / Bluetooth / WiFi / Optional: Ethernet | RS485 / Bluetooth / WiFi / Optional: Ethernet | RS485 / Bluetooth / WiFi / Optional: Ethernet | RS485 / Bluetooth / WiFi / Optional: Ethernet | RS485 / Bluetooth / WiFi / Optional: Ethernet | |
General Information | ||||||||
Ambient Temperature Range | -30°C–+60°C | -30°C–+60°C | -30°C–+60°C | -30°C–+60°C | -30°C–+60°C | -30°C–+60°C | -30°C–+60°C | |
Self-Consumption (W) | <3 | <3 | <3 | <3 | <3 | <3 | <3 | |
Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | |
Protection Class | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | |
Allowed Relative Humidity Range | 0–100% | 0–100% | 0–100% | 0–100% | 0–100% | 0–100% | 0–100% | |
Max. Operating Height (m) | 4000 | 4000 | 4000 | 4000 | 4000 | 4000 | 4000 | |
Noise (dB) | <60 dB | <60 dB | <60 dB | <60 dB | <60 dB | <60 dB | <60 dB | |
Cooling | Fan | Fan | Fan | Fan | Fan | Fan | Fan | |
Weight (kg) | 36 | 36 | 36 | 36 | 37 | 37 | 37 | |
Cooling | Fan | Fan | Fan | Fan | Fan | Fan | Fan | |
Dimensions (mm) | 585*480*220 | 585*480*220 | 585*480*220 | 585*480*220 | 585*480*220 | 585*480*220 | 585*480*220 | |
Display | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | |
Standards | ||||||||
EMC | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 | ||
Safety Standards | IEC 62109-1/2, IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), IEC 60255 | IEC 62109-1/2, IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), IEC 60255 | IEC 62109-1/2, IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), IEC 60255 | IEC 62109-1/2, IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), IEC 60255 | IEC 62109-1/2, IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), IEC 60255 | IEC 62109-1/2, IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), IEC 60255 | ||
Grid Standards | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21/CEI 0-16, UNE 206 007-1, EN 50549, G98/G99, EN 50530 | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21/CEI 0-16, UNE 206 007-1, EN 50549, G98/G99, EN 50530 | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21/CEI 0-16, UNE 206 007-1, EN 50549, G98/G99, EN 50530 | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21/CEI 0-16, UNE 206 007-1, EN 50549, G98/G99, EN 50530 | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21/CEI 0-16, UNE 206 007-1, EN 50549, G98/G99, EN 50530 | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21/CEI 0-16, UNE 206 007-1, EN 50549, G98/G99, EN 50530 | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21/CEI 0-16, UNE 206 007-1, EN 50549, G98/G99, EN 50530 |