Inverter Sofar 3300 TL – G3 / Single-phase
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 1 |
Warranty | |
Net width | |
Net depth | |
Net height | |
Ethernet | Optional |
GPRS | Yes |
RS485 | Yes |
USB | Yes |
Wi-Fi | Yes |
SPD Type II | |
Weight | 8 kg |
CN | 85044085 |
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 1 |
Warranty | |
Net width | |
Net depth | |
Net height | |
Ethernet | Optional |
GPRS | Yes |
RS485 | Yes |
USB | Yes |
Wi-Fi | Yes |
SPD Type II | |
Weight | 8 kg |
CN | 85044085 |
Sofar 1.1k~3.3kTL-G3 – Single-Phase Inverter with a Single MPPT
The Sofar 1.1k~3.3kTL-G3 is a modern single-phase inverter designed for small photovoltaic installations. With advanced features and a compact design, it is perfectly suited for household applications, delivering efficiency and reliability.
Key Features:
- DC Overload 1.4: Enables more efficient use of photovoltaic panels.
- IP65 Protection: Dust and water resistance, allowing for installation both indoors and outdoors.
- Maximum Efficiency: High efficiency reaching up to 97.7%.
- Easy Installation: Lightweight design facilitates quick setup.
- Smart Monitoring: Supports RS485, WiFi, and optional GPRS for easy system management.
Why Choose the Sofar 1.1k~3.3kTL-G3?
The Sofar inverter from the 1.1k~3.3kTL-G3 series combines functionality with simplicity. The built-in zero export feature allows for full utilization of generated energy without sending it back to the grid, leading to cost savings and better energy management. With intuitive monitoring, users have complete control over the system’s performance, while the compact and lightweight housing makes the device easy to handle and install. IP65 protection ensures reliability even in challenging weather conditions.
Data Sheet | SOFAR 3.3KTLX-G3 | SOFAR 4.4KTLX-G3 | SOFAR 5.5KTLX-G3 | SOFAR 6.6KTLX-G3 | SOFAR 8.8KTLX-G3 | SOFAR 11KTLX-G3 | SOFAR 12KTLX-G3 |
---|---|---|---|---|---|---|---|
Input (DC) | |||||||
Recommended Max PV Input Power (Wp) | 4500 | 6000 | 7500 | 9000 | 12000 | 15000 | 18000 |
Number of MPPTs | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Number of DC Inputs | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 2/1 |
Max Input Voltage (V) | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 |
Starting Voltage (V) | 160 | 160 | 160 | 160 | 160 | 160 | 160 |
Nominal Input Voltage (V) | 650 | 650 | 650 | 650 | 650 | 650 | 650 |
MPPT Operating Voltage Range (V) | 140-1000 | 140-1000 | 140-1000 | 140-1000 | 140-1000 | 140-1000 | 140-1000 |
MPPT Voltage Range at Full Power (V) | 160-850 | 190-850 | 240-850 | 290-850 | 380-850 | 420-850 | 460-850 |
Max MPPT Input Current (A) | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 | 30/15 |
Max Short-Circuit Current on MPPT (A) | 22.5/22.5 | 22.5/22.5 | 22.5/22.5 | 22.5/22.5 | 22.5/22.5 | 22.5/22.5 | 45/22.5 |
Output (AC) | |||||||
Rated Power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 |
Max AC Power (VA) | 3300 | 4400 | 5500 | 6600 | 8800 | 11000 | 13200 |
Max Output Current (A) | 4.8 | 6.4 | 8.0 | 9.6 | 12.8 | 15.9 | 19.1 |
Nominal Grid Voltage (Vac) | 3/N/PE, 230 / 400 | 3/N/PE, 230 / 400 | 3/N/PE, 230 / 400 | 3/N/PE, 230 / 400 | 3/N/PE, 230 / 400 | 3/N/PE, 230 / 400 | 3/N/PE, 230 / 400 |
Grid Voltage Range (Vac) | 310 – 480 Vac (according to local standards) | 310 – 480 Vac (according to local standards) | 310 – 480 Vac (according to local standards) | 310 – 480 Vac (according to local standards) | 310 – 480 Vac (according to local standards) | 310 – 480 Vac (according to local standards) | 310 – 480 Vac (according to local standards) |
Nominal Grid Frequency (Hz) | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
Grid Frequency Range (Hz) | 45 – 55 Hz / 55 – 65 Hz (according to local standards) | 45 – 55 Hz / 55 – 65 Hz (according to local standards) | 45 – 55 Hz / 55 – 65 Hz (according to local standards) | 45 – 55 Hz / 55 – 65 Hz (according to local standards) | 45 – 55 Hz / 55 – 65 Hz (according to local standards) | 45 – 55 Hz / 55 – 65 Hz (according to local standards) | 45 – 55 Hz / 55 – 65 Hz (according to local standards) |
Active Power Regulation Range | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% |
THDi | <3% | <3% | <3% | <3% | <3% | <3% | <3% |
Power Factor | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) | 1 default (adjustable +/-0.8) |
Efficiency | |||||||
Max Efficiency (%) | 98.40% | 98.40% | 98.40% | 98.40% | 98.50% | 98.50% | 98.50% |
European Efficiency (%) | 97.50% | 97.50% | 97.50% | 97.50% | 98.00% | 98.00% | 98.00% |
Protection | |||||||
DC Reverse Polarity Protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Island Mode Protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Residual Current Protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Ground Fault Detection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
PV String Fault Monitoring | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Energy Outflow Blocking | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
DC Switch | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
SPD Input/Output | PV: type II standard, AC: type II standard | PV: type II standard, AC: type II standard | PV: type II standard, AC: type II standard | PV: type II standard, AC: type II standard | PV: type II standard, AC: type II standard | PV: type II standard, AC: type II standard | PV: type II standard, AC: type II standard |
Communication | |||||||
Standard Communication Mode | RS485 / WiFi / Bluetooth, optionally: Ethernet | RS485 / WiFi / Bluetooth, optionally: Ethernet | RS485 / WiFi / Bluetooth, optionally: Ethernet | RS485 / WiFi / Bluetooth, optionally: Ethernet | RS485 / WiFi / Bluetooth, optionally: Ethernet | RS485 / WiFi / Bluetooth, optionally: Ethernet | RS485 / WiFi / Bluetooth, optionally: Ethernet |
General Data | |||||||
Ambient Temperature Range | -30°C … +60°C | -30°C … +60°C | -30°C … +60°C | -30°C … +60°C | -30°C … +60°C | -30°C … +60°C | -30°C … +60°C |
Night Power Consumption (W) | <1 | <1 | <1 | <1 | <1 | <1 | <1 |
Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
Protection Rating | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
Permissible Relative Humidity Range | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% |
Max Operating Height | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m |
Noise | <40 dB | <40 dB | <40 dB | <40 dB | <40 dB | <40 dB | <40 dB |
Weight (kg) | 15 | 15 | 15 | 15 | 17 | 17 | 17 |
Cooling | Natural | Natural | Natural | Natural | Natural | Natural | |
Dimensions (mm) | 430*375*179 | 430*375*179 | 430*375*179 | 430*375*179 | 430*375*179 | 430*375*179 | 430*375*179 |
Display | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth | LCD, application via Bluetooth |
Standards | |||||||
EMC | EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 | EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 | EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 | EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 | EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 | EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 | EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
Safety Standards | IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) | IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) | IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) | IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) | IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) | IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) | IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
Grid Standards | VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 | VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 | VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 | VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 | VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 | VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 | VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |