Inverter – DEYE – SUN-10K-SG01HP3-EU-DM2 – hybrid – high-voltage

SKU: F20GZ71 EAN: 2010000037638
Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

CAN

RS485

SPD Type II

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

Weight 30,1 kg
CN 85044086
Price 1 181,64 €
Gross

1 181,64 €
Gross

In stock:

6 pcs
Login to place an order

1 181,64 €
Gross

In stock:

6 pcs
Login to place an order

Datasheet Deye SUN-5K-SG01HP3-EU-DM2 - SUN-12K-SG01HP3-EU-DM2 Deye-SUN-5K-SG01HP3-EU-DM2-SUN-12K-SG01HP3-EU-DM2-Datasheet.pdf Certificate of compliance 1 Deye SUN-5K-SG01HP3-EU-DM2 - SUN-12K-SG01HP3-EU-DM2 Deye-SUN-5K-SG01HP3-EU-DM2-SUN-12K-SG01HP3-EU-DM2-Certificate-of-compliance-1.pdf Certificate of compliance 2 Deye SUN-5K-SG01HP3-EU-DM2 - SUN-12K-SG01HP3-EU-DM2 Deye-SUN-5K-SG01HP3-EU-DM2-SUN-12K-SG01HP3-EU-DM2-Certificate-of-compliance-2.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

CAN

RS485

SPD Type II

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

Weight 30,1 kg
CN 85044086

Three-phase hybrid inverter Deye SUN-5/6/8/10/12K-SG01HP3-EU-DM2

The Deye SUN-5/6/8/10/12K-SG01HP3-EU-DM2 hybrid inverter is an advanced energy management solution that supports both grid-tied and off-grid operation. It delivers high reliability and flexibility by working with high-voltage batteries and integrating with existing photovoltaic systems.

Key features of the SUN-5/6/8/10/12K-SG01HP3-EU-DM2:

  • 100% independent output on each phase for maximum flexibility.
  • Easy AC-coupling retrofit for existing solar systems.
  • Up to 16 inverters can operate in parallel in grid-tied and off-grid modes, with support for multiple batteries in parallel.
  • High-voltage battery support (160–700 V) for greater system efficiency.
  • Six charge/discharge periods for optimal energy management.
  • Support for energy storage from a diesel generator to increase power reliability.

Who is this a good choice for?

This inverter is ideal for homeowners and commercial installations seeking an efficient, flexible solar energy management solution. It is well suited for systems that need off-grid capability, scalability, and integration with existing infrastructure. Features like multi-battery support and independent phase outputs make it a versatile option for modern photovoltaic installations.

Datasheet Deye SUN-5K-SG01HP3-EU-DM2 - SUN-12K-SG01HP3-EU-DM2 Deye-SUN-5K-SG01HP3-EU-DM2-SUN-12K-SG01HP3-EU-DM2-Datasheet.pdf Certificate of compliance 1 Deye SUN-5K-SG01HP3-EU-DM2 - SUN-12K-SG01HP3-EU-DM2 Deye-SUN-5K-SG01HP3-EU-DM2-SUN-12K-SG01HP3-EU-DM2-Certificate-of-compliance-1.pdf Certificate of compliance 2 Deye SUN-5K-SG01HP3-EU-DM2 - SUN-12K-SG01HP3-EU-DM2 Deye-SUN-5K-SG01HP3-EU-DM2-SUN-12K-SG01HP3-EU-DM2-Certificate-of-compliance-2.pdf

Parameter SUN-5K-SG01HP3-EU-DM2 SUN-6K-SG01HP3-EU-DM2 SUN-8K-SG01HP3-EU-DM2 SUN-10K-SG01HP3-EU-DM2 SUN-12K-SG01HP3-EU-DM2
Battery input
Battery type Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion Lead-acid or lithium-ion
Battery voltage range (V) 160-700 160-700 160-700 160-700 160-700
Max. charging current (A) 37 37 37 37 37
Max. discharging current (A) 37 37 37 37 37
Charging strategy for Li-ion battery Self-adapts to BMS Self-adapts to BMS Self-adapts to BMS Self-adapts to BMS Self-adapts to BMS
Number of battery ports 1 1 1 1 1
PV input
Maximum PV access power (W) 10000 12000 16000 20000 24000
Max. PV input power (W) 8000 9600 12800 16000 19200
Max. PV input voltage (V) 1000 1000 1000 1000 1000
Start-up voltage (V) 180 180 180 180 180
MPPT voltage range (V) 150-850 150-850 150-850 150-850 150-850
Rated DC input voltage (V) 600 600 600 600 600
Max. PV input current (A) 18+18 18+18 18+18 18+18 18+18
Max. short-circuit current (A) 27+27 27+27 27+27 27+27 27+27
Number of MPP / Number of MPPT strings 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1
AC input/output
Rated AC active power (W) 5000 6000 8000 10000 12000
Max. AC apparent power (W) 5500 6600 8800 11000 13200
Rated AC input/output current (A) 7.6/7.3 9.1/8.7 12.2/11.6 15.2/14.5 18.2/17.4
Max. AC input/output current (A) 8.4/8 10/9.6 13.4/12.8 16.7/16 20/19.2
Max. bypass port Grid->Load current (A) 35 35 35 35 35
Peak power (off-grid) (W) 2× rated power, 10s 2× rated power, 10s 2× rated power, 10s 2× rated power, 10s 2× rated power, 10s
Power factor 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging
Rated input/output voltage / range (V) 220/230 0.85Un-1.1Un 220/230 0.85Un-1.1Un 220/230 0.85Un-1.1Un 220/230 0.85Un-1.1Un 220/230 0.85Un-1.1Un
Rated grid frequency (Hz) 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
Grid connection 3L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE
Total harmonic current distortion (THD) <3% (at rated power) <3% (at rated power) <3% (at rated power) <3% (at rated power) <3% (at rated power)
DC input current <0.5% In <0.5% In <0.5% In <0.5% In <0.5% In
Efficiency
Max. efficiency 97.6% 97.6% 97.6% 97.6% 97.6%
Euro efficiency 96.5% 96.5% 96.5% 96.5% 96.5%
MPPT efficiency >99% >99% >99% >99% >99%
Protections
Surge protection level TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC)
Integrated DC reverse polarity protection, AC output overcurrent protection, AC output surge protection, AC output short-circuit protection, Thermal protection, Insulation resistance detection, DC component monitoring, Residual current device (AFCI), DC switch, Anti-islanding protection, Leakage current detection
Communication
Display LCD/LED LCD+LED LCD+LED LCD+LED LCD+LED LCD+LED
Communication interface RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN
Monitoring mode GPRS/WiFi/Bluetooth/4G/LAN (optional) GPRS/WiFi/Bluetooth/4G/LAN (optional) GPRS/WiFi/Bluetooth/4G/LAN (optional) GPRS/WiFi/Bluetooth/4G/LAN (optional) GPRS/WiFi/Bluetooth/4G/LAN (optional)
General specifications
Operating temperature (C) -40 to +60°C, derating above 45°C -40 to +60°C, derating above 45°C -40 to +60°C, derating above 45°C -40 to +60°C, derating above 45°C -40 to +60°C, derating above 45°C
Permissible ambient humidity 0-100% 0-100% 0-100% 0-100% 0-100%
Max. installation altitude 2000m 2000m 2000m 2000m 2000m
Noise level (dB) ≤45 dB ≤45 dB ≤45 dB ≤45 dB ≤45 dB
Inverter topology Transformerless Transformerless Transformerless Transformerless Transformerless
Overvoltage category OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC)
Weight (kg) 24 24 24 24 24
Cabinet size (W x H x D mm) 376×470×244.5 (Without connectors and mounting brackets) 376×470×244.5 (Without connectors and mounting brackets) 376×470×244.5 (Without connectors and mounting brackets) 376×470×244.5 (Without connectors and mounting brackets) 376×470×244.5 (Without connectors and mounting brackets)
IP rating IP65 IP65 IP65 IP65 IP65
Cooling type Intelligent air cooling Intelligent air cooling Intelligent air cooling Intelligent air cooling Intelligent air cooling
Warranty 5-year / 10-year warranty period depends on inverter installation conditions. Details are available in the general warranty terms. 5-year / 10-year warranty period depends on inverter installation conditions. Details are available in the general warranty terms. 5-year / 10-year warranty period depends on inverter installation conditions. Details are available in the general warranty terms. 5-year / 10-year warranty period depends on inverter installation conditions. Details are available in the general warranty terms. 5-year / 10-year warranty period depends on inverter installation conditions. Details are available in the general warranty terms.
Grid connection standard IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105
EMC / Safety standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Official distribution