Inverter DEYE SUN-15K-SG05LP3-EU
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 2 |
Warranty | |
Net width | |
Net depth | |
Net height | |
RS485 | Yes |
RS232 | Yes |
CAN | Yes |
SPD Type II | |
Weight | 65,8 kg |
CN | 85044086 |
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 2 |
Warranty | |
Net width | |
Net depth | |
Net height | |
RS485 | Yes |
RS232 | Yes |
CAN | Yes |
SPD Type II | |
Weight | 65,8 kg |
CN | 85044086 |
Three-Phase Hybrid Inverter Deye SUN-14/15/16/18/20K-SG05LP3-EU-SM2
The Deye three-phase hybrid inverters from the SUN-K-SG05LP3-EU-SM2 series are advanced and versatile devices designed for large photovoltaic installations in homes and small businesses. They offer high output power (ranging from 14 to 20 kW) and are compatible with low-voltage (48V) energy storage systems. With the capability for parallel operation, support for diesel generators, and AC coupling functionality, these inverters ensure flexibility, reliability, and optimal energy management.
Key Features of Deye SUN-K-SG05LP3-EU-SM2 Inverters:
- Hybrid Versatility: Efficient collaboration with the power grid, photovoltaic installation, and low-voltage (48V) lead-acid or lithium-ion batteries.
- High Power and Efficiency: Models with rated power ranging from 14 kW to 20 kW with a maximum efficiency of up to 97.6%.
- Unbalanced Load Handling: Ability to deliver up to 100% of rated power on a single phase, with a maximum output power per phase of up to 50% of the inverter’s rated power.
- Flexibility and Scalability: AC coupling feature for upgrading existing PV systems, support for connecting a diesel generator, and the possibility of parallel operation with multiple units (depending on configuration).
- Advanced Energy Management: 6 programmable charging and discharging periods for optimizing energy consumption and costs.
- High Charging/Discharging Current: Maximum charging/discharging current of up to 350A (depending on the model), allowing for rapid energy management in the battery.
Who is it a good choice for?
The Deye SUN-K-SG05LP3-EU-SM2 series inverters are an excellent choice for owners of larger homes, farms, or small businesses with three-phase energy connections who are looking for an efficient and flexible hybrid solution. They are ideal for users who need high output power, the capability to support unbalanced loads, emergency power options (including from a generator), and who prefer working with safe, low-voltage battery systems.
Model | SUN-14K-SG05LP3-EU-SM2 | SUN-15K-SG05LP3-EU-SM2 | SUN-16K-SG05LP3-EU-SM2 | SUN-18K-SG05LP3-EU-SM2 | SUN-20K-SG05LP3-EU-SM2 |
---|---|---|---|---|---|
Battery Input Data | |||||
Battery Type | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
Max. Charging Current (A) | 260 | 280 | 300 | 330 | 350 |
Max. Discharging Current (A) | 260 | 280 | 300 | 330 | 350 |
Charging Strategy for Lithium-ion Battery | Self-adaptive to BMS | Self-adaptive to BMS | Self-adaptive to BMS | Self-adaptive to BMS | Self-adaptive to BMS |
Number of Battery Ports | 1 | 1 | 1 | 1 | 1 |
PV Input Data | |||||
Max. PV Input Power (W) | 28000 | 30000 | 32000 | 36000 | 40000 |
Max. PV Input Power (W) | 22400 | 24000 | 25600 | 28800 | 32000 |
Max. PV Input Voltage (V) | 800 | 800 | 800 | 800 | 800 |
Start Voltage (V) | 160 | 160 | 160 | 160 | 160 |
MPPT Voltage Range (V) | 160-650 | 160-650 | 160-650 | 160-650 | 160-650 |
Rated DC Input Voltage (V) | 550 | 550 | 550 | 550 | 550 |
Max. PV Input Current (A) | 36+36 | 36+36 | 36+36 | 36+36 | 36+36 |
Max. Short-Circuit Current (A) | 54+54 | 54+54 | 54+54 | 54+54 | 54+54 |
Number of MPP / Number of MPPT Strings | 2 / 2+2 | 2 / 2+2 | 2 / 2+2 | 2 / 2+2 | 2 / 2+2 |
AC Input/Output Data | |||||
Rated Active Power AC (W) | 14000 | 15000 | 16000 | 18000 | 20000 |
Max. Apparent Power AC (W) | 14000 | 15000 | 16000 | 18000 | 20000 |
Rated AC Input/Output Current (A) | 21.3/20.3 | 22.8/21.8 | 24.3/23.2 | 27.3/26.1 | 30.4/29 |
Max. AC Input/Output Current (A) | 23.4/22.4 | 25/24 | 26.7/25.6 | 30/28.7 | 33.4/31.9 |
Max. Bypass Current Grid->Load (A) | 70 | 70 | 70 | 70 | 70 |
Peak Power (off-grid) (W) | 2× rated power, 10s | 2× rated power, 10s | 2× rated power, 10s | 2× rated power, 10s | 2× rated power, 10s |
Power Factor | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
Rated Voltage Input/Output/Range (V) | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un |
Rated Network Frequency (Hz) | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 |
Connection Type to the Grid | 3L+N+PE | 3L+N+PE | 3L+N+PE | 3L+N+PE | 3L+N+PE |
Total Harmonic Distortion Current (THDi) | <3% (of rated power) | <3% (of rated power) | <3% (of rated power) | <3% (of rated power) | <3% (of rated power) |
DC Input Current | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In |
Efficiency | |||||
Max. Efficiency | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% |
Euro Efficiency | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% |
MPPT Efficiency | >99% | >99% | >99% | >99% | >99% |
Protections | |||||
Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Surge Protection for Load Drop, Earth Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Grid Monitoring, Islanding Protection Monitoring, Ground Fault Detection, DC Input Switch, DC Terminal Insulation Resistance Monitoring, Residual Current Detection (RCD), Surge Protective Device Level | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Surge Protection for Load Drop, Earth Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Grid Monitoring, Islanding Protection Monitoring, Ground Fault Detection, DC Input Switch, DC Terminal Insulation Resistance Monitoring, Residual Current Detection (RCD), Surge Protective Device Level | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Surge Protection for Load Drop, Earth Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Grid Monitoring, Islanding Protection Monitoring, Ground Fault Detection, DC Input Switch, DC Terminal Insulation Resistance Monitoring, Residual Current Detection (RCD), Surge Protective Device Level | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Surge Protection for Load Drop, Earth Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Grid Monitoring, Islanding Protection Monitoring, Ground Fault Detection, DC Input Switch, DC Terminal Insulation Resistance Monitoring, Residual Current Detection (RCD), Surge Protective Device Level | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Surge Protection for Load Drop, Earth Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Grid Monitoring, Islanding Protection Monitoring, Ground Fault Detection, DC Input Switch, DC Terminal Insulation Resistance Monitoring, Residual Current Detection (RCD), Surge Protective Device Level |
Surge Protective Device Level | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) |
Communication | |||||
Communication Interface | RS485/RS232/CAN | RS485/RS232/CAN | RS485/RS232/CAN | RS485/RS232/CAN | RS485/RS232/CAN |
Monitoring Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | GPRS/WIFI/Bluetooth/4G/LAN (optional) | GPRS/WIFI/Bluetooth/4G/LAN (optional) | GPRS/WIFI/Bluetooth/4G/LAN (optional) | GPRS/WIFI/Bluetooth/4G/LAN (optional) |
General Data | |||||
Operating Temperature (°C) | -40 to +60°C, >45°C derating | -40 to +60°C, >45°C derating | -40 to +60°C, >45°C derating | -40 to +60°C, >45°C derating | -40 to +60°C, >45°C derating |
Allowable Ambient Humidity | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
Max. Installation Height | 3000m | 3000m | 3000m | 3000m | 3000m |
Noise Level (dB) | ≤55 dB(A) | ≤55 dB(A) | ≤55 dB(A) | ≤55 dB(A) | ≤55 dB(A) |
IP Protection Level | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 |
Inverter Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
Overvoltage Category | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) |
Cabinet Size (W × H × D mm) | 456×750×268.5 (Without connectors and mounting brackets) | 456×750×268.5 (Without connectors and mounting brackets) | 456×750×268.5 (Without connectors and mounting brackets) | 456×750×268.5 (Without connectors and mounting brackets) | 456×750×268.5 (Without connectors and mounting brackets) |
Weight (kg) | 50.6 | 50.6 | 50.6 | 50.6 | 50.6 |
Cooling Type | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling |
Warranty | 5 years/10 years warranty depends on the installation conditions of the inverter. Details available in the general warranty conditions. | 5 years/10 years warranty depends on the installation conditions of the inverter. Details available in the general warranty conditions. | 5 years/10 years warranty depends on the installation conditions of the inverter. Details available in the general warranty conditions. | 5 years/10 years warranty depends on the installation conditions of the inverter. Details available in the general warranty conditions. | 5 years/10 years warranty depends on the installation conditions of the inverter. Details available in the general warranty conditions. |
Grid Connection Standard | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
EMC Safety/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |