Inverter DEYE SUN-6K-SG05LP3-EU
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Sprawność europejska | |
| Weight | 42,56 kg |
| CN | 85044085 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Sprawność europejska | |
| Weight | 42,56 kg |
| CN | 85044085 |
Three-phase Hybrid Inverters Deye SUN-3/4/5/6K-SG05LP3-EU-SM2
The Deye three-phase hybrid inverters from the SUN-K-SG05LP3-EU-SM2 series are versatile and efficient devices designed for residential and small commercial photovoltaic installations. They offer power ratings from 3 kW to 6 kW, 100% unbalanced output on each phase, and the ability to operate in parallel with up to 10 units. Compatible with low-voltage 48V batteries, featuring AC-couple functionality and support for storing energy from a diesel generator, these inverters provide flexibility and reliability in energy management.
Key features of the Deye SUN-K-SG05LP3-EU-SM2 Hybrid Inverters:
- 100% unbalanced output: Ability to deliver up to 50% of rated power on a single phase, which is important for uneven household loads.
- High scalability and parallel operation: Up to 10 units can be connected in parallel, both in on-grid and off-grid modes, with support for multiple batteries connected in parallel.
- Compatibility with 48V batteries: Transformer-isolated design intended for use with common low-voltage 48V batteries (lead-acid or lithium-ion), with maximum charge/discharge current up to 135A.
- Advanced energy management: Ability to set 6 battery charge/discharge periods, AC-couple feature for upgrading existing solar systems, and support for storing energy from a diesel generator.
- High efficiency and reliability: Maximum efficiency up to 97.6%, MPPT efficiency >99%, and numerous integrated protections, including DC reverse polarity protection and AC/DC surge protection (Type II).
- Emergency power: In off-grid mode the inverter can supply twice its rated power for 10 seconds, enabling the start-up of demanding appliances.
Who is this a good choice for?
The Deye hybrid inverters in this series are an excellent choice for single-family homeowners and small businesses seeking a flexible, efficient, and reliable energy management solution. Their ability to handle unbalanced loads, expand the system, and work with common low-voltage 48V batteries makes them ideal for maximizing self-consumption, providing backup power, and upgrading existing photovoltaic installations.
| Parameter | SUN-3K-SG05LP3-EU-SM2 | SUN-4K-SG05LP3-EU-SM2 | SUN-5K-SG05LP3-EU-SM2 | SUN-6K-SG05LP3-EU-SM2 |
|---|---|---|---|---|
| Battery input data | ||||
| Battery type | Lead-acid or lithium-ion | Lead-acid or lithium-ion | Lead-acid or lithium-ion | Lead-acid or lithium-ion |
| Battery voltage range (V) | 40-60 | 40-60 | 40-60 | 40-60 |
| Max. charging current (A) | 70 | 95 | 120 | 135 |
| Max. discharging current (A) | 70 | 95 | 120 | 135 |
| Charging strategy for Li-ion batteries | Auto-adaptation to BMS | Auto-adaptation to BMS | Auto-adaptation to BMS | Auto-adaptation to BMS |
| Number of battery inputs | 1 | 1 | 1 | 1 |
| PV input data | ||||
| Max. PV input power (W) | 4500 | 6000 | 7500 | 9000 |
| Max. PV input voltage (V) | 800 | 800 | 800 | 800 |
| Start voltage (V) | 160 | 160 | 160 | 160 |
| MPPT voltage range (V) | 200-650 | 200-650 | 200-650 | 200-650 |
| Rated PV input voltage (V) | 550 | 550 | 550 | 550 |
| Max. operating PV input current (A) | 20+20 | 20+20 | 20+20 | 20+20 |
| Max. short-circuit input current (A) | 30+30 | 30+30 | 30+30 | 30+30 |
| Number of MPP trackers / strings per MPP tracker | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 |
| AC input/output data | ||||
| Rated AC input/output active power (W) | 3000 | 4000 | 5000 | 6000 |
| Max AC input/output apparent power (VA) | 3300 | 4400 | 5500 | 6600 |
| Rated AC input/output current (A) | 4.6/4.4 | 6.1/5.8 | 7.6/7.3 | 9.1/8.7 |
| Max AC input/output current (A) | 5/4.8 | 6.7/6.4 | 8.4/8 | 10/9.6 |
| Max unbalanced current of three-phase output (A) | 6.9/6.6 | 9.1/8.7 | 11.4/10.9 | 13.7/13.1 |
| Max continuous AC transfer current (grid to load) (A) | 45 | 45 | 45 | 45 |
| Peak power (off-grid) | 2× rated power, 10 s | 2× rated power, 10 s | 2× rated power, 10 s | 2× rated power, 10 s |
| Power factor adjustment range | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
| Rated voltage / input/output range (V) | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un | 220/380V, 230/400V 0.85Un-1.1Un |
| Rated frequency / grid input/output range (Hz) | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 |
| Grid connection type | 3L+N+PE | 3L+N+PE | 3L+N+PE | 3L+N+PE |
| Total harmonic distortion of current (THDI) | <3% (rated power) | <3% (rated power) | <3% (rated power) | <3% (rated power) |
| Injected DC current | <0.5% In | <0.5% In | <0.5% In | <0.5% In |
| Efficiency | ||||
| Max. efficiency (%) | 97.6% | 97.6% | 97.6% | 97.6% |
| Euro efficiency (%) | 97.0% | 97.0% | 97.0% | 97.0% |
| MPPT efficiency (%) | >99% | >99% | >99% | >99% |
| Protections | ||||
| Integrated protections | DC reverse polarity protection, AC output overcurrent protection, AC output surge protection, AC output short-circuit protection, Thermal protection, DC terminal insulation impedance monitoring, DC component monitoring, Leakage current monitoring, Grid monitoring, Anti-islanding protection, Earth fault detection, DC input switch, Surge protection with discharge, Residual current detection (RCD), Surge protection | |||
| Surge protection level | TYP II(DC), TYP II(AC) | TYP II(DC), TYP II(AC) | TYP II(DC), TYP II(AC) | TYP II(DC), TYP II(AC) |
| Interface | ||||
| Communication interface | RS485/RS232/CAN | RS485/RS232/CAN | RS485/RS232/CAN | RS485/RS232/CAN |
| Monitoring mode | GPRS/WiFi/Bluetooth/4G/LAN (optional) | GPRS/WiFi/Bluetooth/4G/LAN (optional) | GPRS/WiFi/Bluetooth/4G/LAN (optional) | GPRS/WiFi/Bluetooth/4G/LAN (optional) |
| General data | ||||
| Operating temperature range (°C) | -40 to +60°C, >45°C power derating | -40 to +60°C, >45°C power derating | -40 to +60°C, >45°C power derating | -40 to +60°C, >45°C power derating |
| Ambient humidity (%) | 0-100% | 0-100% | 0-100% | 0-100% |
| Maximum altitude (m) | 3000 | 3000 | 3000 | 3000 |
| Noise level (dB) | ≤55 | ≤55 | ≤55 | ≤55 |
| Ingress protection (IP) | IP 65 | IP 65 | IP 65 | IP 65 |
| Inverter topology | Transformerless | Transformerless | Transformerless | Transformerless |
| Overvoltage category | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) |
| Enclosure dimensions (W x H x D mm) | 386×660×253 (excluding connectors and handles) | 386×660×253 (excluding connectors and handles) | 386×660×253 (excluding connectors and handles) | 386×660×253 (excluding connectors and handles) |
| Weight (kg) | 35.2 | 35.2 | 35.2 | 35.2 |
| Cooling type | Intelligent air cooling | Intelligent air cooling | Intelligent air cooling | Intelligent air cooling |
| Warranty and Standards | ||||
| Warranty | 5 years / 10 years (Warranty period depends on the final installation location of the inverter. See the warranty policy for more information.) | |||
| Grid regulations | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | |||
| Safety / EMC standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||