FoxESS P3-10.0-SH Hybrid Inverter
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 37,9 kg |
| CN | 85044086 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 37,9 kg |
| CN | 85044086 |
Three-phase Hybrid Inverter Fox ESS P3-5 (P3-SH Series)
The innovative three-phase hybrid inverters from Fox ESS’s P3-SH series are designed to maximize solar energy use during the day and store excess energy for nighttime. Equipped with advanced technology and compatibility with Fox ESS high-voltage batteries, they provide flexible and efficient energy management.
Key features of the Fox ESS P3-5:
- High compatibility with HV batteries: Seamless integration with Fox ESS high-voltage lithium‑ion batteries from 100–800 V for optimal energy storage.
- Exceptional efficiency: Peak efficiency up to 97.90% and an impressive MPPT efficiency of 99.90%, ensuring effective energy conversion.
- Wide power range: Available AC rated powers from 5 kW to 15 kW and maximum PV input power up to 30 kW, offering flexibility to suit different installation needs.
- Smart monitoring and ease of use: Remote system monitoring via mobile app or web portal (FoxCloud V2.0) and quick, intuitive plug-and-play installation.
- Durability and comprehensive protection: IP65-rated enclosure enables installation in diverse environments, complemented by full protections including reverse polarity prevention, anti-islanding, and overload protection.
- Long warranty: Standard 10-year manufacturer’s warranty confirming the device’s reliability and longevity.
Who is this a good choice for?
The Fox ESS P3-SH inverters are an excellent choice for homeowners and small to medium-sized businesses looking to optimize self-consumption of solar energy and increase energy independence. With three-phase design, high efficiency, flexible energy storage options, and remote monitoring, they are ideal for PV systems that require reliable, advanced energy management.
| Parameter | P3-5.0-SH | P3-6.0-SH | P3-8.0-SH | P3-9.9-SH | P3-10.0-SH | P3-12.0-SH | P3-15.0-SH |
|---|---|---|---|---|---|---|---|
| PV INPUT | |||||||
| Max PV Power (Wp) | 11000 | 14000 | 18000 | 20000 | 20000 | 24000 | 30000 |
| Max Input Power (W) | 11000 | 13200 | 17600 | 18000 | 18000 | 22500 | 22500 |
| Max Input Voltage (V) | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] | 1000 [1] |
| Nominal Input Voltage (V) | 620 | 620 | 620 | 620 | 620 | 620 | 620 |
| Max MPPT Input Current (A) | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 | 20/20/20 |
| Max MPPT Short-circuit Current (A) | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 | 25/25/25 |
| Max MPPT Input Power (W) | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 | 10000/10000/10000 |
| Min PV Operating Voltage (V) | 90 [2] | 90 [2] | 90 [2] | 90 [2] | 90 [2] | 90 [2] | 90 [2] |
| MPPT Operating Voltage Range (V) | 120~950 | 120~950 | 120~950 | 120~950 | 120~950 | 120~950 | 120~950 |
| Start-up Voltage (V) | 140 | 140 | 140 | 140 | 140 | 140 | 140 |
| Number of Independent MPPTs | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Strings per MPPT | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 | 1+1+1 |
| BATTERIES | |||||||
| Battery Type | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) | Lithium-Ion battery (LFP) |
| Battery Voltage Range (V) | 100~800 | 100~800 | 100~800 | 100~800 | 100~800 | 100~800 | 100~800 |
| Min Battery Operating Voltage (V) | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
| Min Battery Voltage for Full AC Load (V) | 108 | 125 | 160 | 210 | 210 | 250 | 310 |
| Max Charge/Discharge Current (A) | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Communication Interface | CAN | CAN | CAN | CAN | CAN | CAN | CAN |
| AC OUTPUT | |||||||
| Rated Output Power (W) | 5000 | 6000 | 8000 | 9900 | 10000 | 12000 | 15000 |
| Max Apparent Power (VA) | 5500 | 6600 | 8800 | 9900 | 11000 [3] | 13200 | 16500 |
| Nominal grid voltage (AC voltage range) (V) | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE |
| Rated Grid Frequency (Hz) | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 |
| Rated AC Current (A) (per phase) | 7,6 | 9,1 | 12,1 | 15,0 | 15,2 | 18,2 | 22,7 |
| Max AC Current (A) (per phase) | 8,3 | 10,0 | 13,3 | 15,0 | 16,7 | 20,0 | 25,0 |
| Power Factor | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) |
| THDI (%) | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power | <3 at rated power |
| AC INPUT | |||||||
| Max AC Input Power (VA) | 6000 | 7200 | 9600 | 12000 | 12000 | 14400 | 16000 |
| Nominal AC Grid Voltage (V) | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE |
| Nominal AC Grid Frequency (Hz) | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 | 50/60, ±5 |
| Max AC Current (A) (per phase) | 9,1 | 10,9 | 14,5 | 18,2 | 18,2 | 21,8 | 24,2 |
| EPS OUTPUT | |||||||
| Max Apparent Power (VA) | 5000 | 6000 | 8000 | 10000 | 10000 | 12000 | 15000 |
| Peak Apparent Power (VA) (60s) | 6000 | 7200 | 9600 | 12000 | 12000 | 14400 | 15000 |
| Nominal EPS Grid Voltage (V) | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE | 400/230Vac; 380/220Vac, 3L/N/PE |
| Nominal EPS Grid Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| Max EPS Current (A) (per phase) | 7,2 | 8,7 | 11,6 | 14,5 | 14,5 | 17,4 | 21,7 |
| Power Factor | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) | 1 (Adjustable from 0.8 capacitive to 0.8 inductive) |
| Transfer Time (ms) | <20 | <20 | <20 | <20 | <20 | <20 | |
| THDV (%) | <3 @Linear load | <3 @Linear load | <3 @Linear load | <3 @Linear load | <3 @Linear load | <3 @Linear load | <3 @Linear load |
| EFFICIENCY | |||||||
| MPPT Efficiency (%) | 99.90 | 99.90 | 99.90 | 99.90 | 99.90 | 99.90 | 99.90 |
| Max Efficiency (%) | 97.30 | 97.70 | 97.70 | 97.90 | 97.90 | 97.90 | 97.90 |
| European Efficiency (%) | 97.20 | 97.20 | 97.20 | 97.20 | 97.20 | 97.20 | 97.20 |
| PROTECTIONS | |||||||
| PV Reverse Polarity Protection | YES | YES | YES | YES | YES | YES | YES |
| Battery Reverse Polarity Protection | YES | YES | YES | YES | YES | YES | YES |
| Anti-islanding Protection | YES | YES | YES | YES | YES | YES | YES |
| Short-circuit Protection | YES | YES | YES | YES | YES | YES | YES |
| Leakage Current Monitoring | YES | YES | YES | YES | YES | YES | YES |
| Insulation Resistance Monitoring | YES | YES | YES | YES | YES | YES | YES |
| Surge Category | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) | III (AC side), II (DC side) |
| Reverse Polarity Protection | YES | YES | YES | YES | YES | YES | YES |
| Overcurrent / Overtemperature Protection | YES | YES | YES | YES | YES | YES | YES |
| AC/DC Surge Protection | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) | Type II(PV)/Type II(AC) |
| AFCI Protection | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
| DC Isolator | YES | YES | YES | YES | YES | YES | YES |
| GENERAL DATA | |||||||
| Dimensions (W*H*D) (mm) | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 | 600*450*226 |
| Package Dimensions (W*H*D) (mm) | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 | 665*545*390 |
| Net Weight (kg) | 34 | 34 | 34 | 34 | 34 | 34 | 34 |
| Gross Weight (kg) | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| Installation | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted |
| Operating Temperature Range (°C) | -25~+60 (Limitation at 45) | -25~+60 (Limitation at 45) | -25~+60 (Limitation at 45) | -25~+60 (Limitation at 45) | -25~+60 (Limitation at 45) | -25~+60 (Limitation at 45) | -25~+60 (Limitation at 45) |
| Storage Temperature (°C) | -40~+70 | -40~+70 | -40~+70 | -40~+70 | -40~+70 | -40~+70 | -40~+70 |
| Relative Humidity (storage/operation) (%) | 0~100 | 0~100 | 0~100 | 0~100 | 0~100 | 0~100 | 0~100 |
| Altitude (m) | <4000 m (limited above 2000 m) | <4000 m (limited above 2000 m) | <4000 m (limited above 2000 m) | <4000 m (limited above 2000 m) | <4000 m (limited above 2000 m) | <4000 m (limited above 2000 m) | <4000 m (limited above 2000 m) |
| Protection Class | I | I | I | I | I | I | I |
| Protection Rating | IP65 (Outdoor use) | IP65 (Outdoor use) | IP65 (Outdoor use) | IP65 (Outdoor use) | IP65 (Outdoor use) | IP65 (Outdoor use) | IP65 (Outdoor use) |
| Power Consumption (W) | 20~25 | 20~25 | 20~25 | 20~25 | 20~25 | 20~25 | 20~25 |
| Idle Mode | YES | YES | YES | YES | YES | YES | YES |
| Cooling | Natural | Natural | Natural | Natural | Natural | Fan cooling | Fan cooling |
| Noise Level (dB) | <40 | <40 | <40 | <40 | <40 | <55 | <55 |
| Inverter Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
| Communication | Ethernet, EMS(RS485), meter, WLAN(WiFi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WLAN(WiFi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WLAN(WiFi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WLAN(WiFi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WLAN(WiFi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WLAN(WiFi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready | Ethernet, EMS(RS485), meter, WLAN(WiFi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready |
| Standard Warranty (Years) | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Button | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons | 4* Capacitive touch buttons |
| Buzzer | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) | 1, Internal (EPS and ground fault) |
Notes:
[1] For 1000 V systems, the maximum PV operating voltage is 950 V.
[2] The inverter start-up voltage is 90 V.
[3] Belgian safety regulations require the 10000 W rating to correspond to 10000 VA.
Version 1.0 | 2025/02/05