FoxESS P3-8.0-SH Hybrid Inverter

SKU: F290B61 EAN: 2010000034590
Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

3

Warranty

Net width

Net depth

Net height

CAN

Yes

RS485

Yes

SPD Type II

AFCI

Optional

MPPT voltage range

Weight 37,9 kg
CN 85044086
Price 1 536,36 
Gross

1 536,36 
Gross

In stock:

7 pcs
Login to place an order

1 536,36 
Gross

In stock:

7 pcs
Login to place an order

Datasheet FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Datasheet.pdf Declaration of confirmity FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Declaration-of-confirmity.pdf Certificate of compliance 1 FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Certificate-of-compliance-1.pdf Certificate of compliance 2 FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Certificate-of-compliance-2.pdf Statement FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Statement.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

3

Warranty

Net width

Net depth

Net height

CAN

Yes

RS485

Yes

SPD Type II

AFCI

Optional

MPPT voltage range

Weight 37,9 kg
CN 85044086

FOX P3-S Three-Phase Hybrid Inverter

The Fox ESS P3-S series hybrid inverters are technologically advanced devices designed for efficient solar energy management. They enable daytime use and nighttime storage of energy and are compatible with Fox ESS high-voltage batteries. They feature easy installation, resistance to outdoor conditions (IP65), and remote monitoring capabilities.

Key features of the FOX P3-S:

  • Flexible power range from 5 kW to 15 kW, adaptable to installation needs.
  • Works with high-voltage Lithium-Ion (LFP) batteries in the 100–800 V range.
  • Three independent Maximum Power Point Tracking (MPPT) inputs for optimal PV performance.
  • High MPPT efficiency up to 97.90% and peak efficiency up to 99.90%.
  • IP65 ingress protection rating, allowing installation in various environments, including outdoors.
  • Advanced system monitoring via a mobile app or web portal (FoxCloud V2.0).

Who is this a good choice for?

The Fox ESS P3-S inverters are an ideal solution for residential and commercial users seeking an efficient and flexible renewable energy management system. Their plug-and-play design, robust protection, and battery integration make them an excellent choice for photovoltaic installations aimed at maximizing self-consumption of solar energy and ensuring reliable power supply.

Datasheet FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Datasheet.pdf Declaration of confirmity FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Declaration-of-confirmity.pdf Certificate of compliance 1 FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Certificate-of-compliance-1.pdf Certificate of compliance 2 FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Certificate-of-compliance-2.pdf Statement FoxESS P3-5.0-SH - P3-15.0-SH FoxESS-P3-5.0-SH-P3-15.0-SH-Statement.pdf

Parameter P3-5.0-SH P3-6.0-SH P3-8.0-SH P3-9.0-SH P3-10.0-SH P3-12.0-SH P3-15.0-SH
PV INPUT
Max PV Power (W) 11000 14000 18000 20000 20000 24000 30000
Max DC Input Power (W) 11000 13200 17600 18000 18000 22500 22500
Max Input Voltage (V) 1000 [1] 1000 [1] 1000 [1] 1000 [1] 1000 [1] 1000 [1] 1000 [1]
Nominal Input Voltage (V) 620 620 620 620 620 620 620
Max MPPT Input Current (A) 20/20/20 20/20/20 20/20/20 20/20/20 20/20/20 20/20/20 20/20/20
Max MPPT Short-Circuit Current (A) 25/25/25 25/25/25 25/25/25 25/25/25 25/25/25 25/25/25 25/25/25
Max MPPT Input Power (W) 10000/10000/10000 10000/10000/10000 10000/10000/10000 10000/10000/10000 10000/10000/10000 10000/10000/10000 10000/10000/10000
Min PV Operating Voltage (V) 90 [2] 90 [2] 90 [2] 90 [2] 90 [2] 90 [2] 90 [2]
MPPT Operating Voltage Range (V) 120 ~ 950 120 ~ 950 120 ~ 950 120 ~ 950 120 ~ 950 120 ~ 950 120 ~ 950
Start-up Voltage (V) 140 140 140 140 140 140 140
Number of Independent MPPTs 3 3 3 3 3 3 3
Strings per MPPT 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1
BATTERY
Battery Type Lithium-Ion battery (LFP) Lithium-Ion battery (LFP) Lithium-Ion battery (LFP) Lithium-Ion battery (LFP) Lithium-Ion battery (LFP) Lithium-Ion battery (LFP) Lithium-Ion battery (LFP)
Battery Voltage Range (V) 100 ~ 800 100 ~ 800 100 ~ 800 100 ~ 800 100 ~ 800 100 ~ 800 100 ~ 800
Min Battery Operating Voltage (V) 100 100 100 100 100 100 100
Min Battery Voltage at Full AC Load (V) 108 125 160 210 210 250 310
Max Charge/Discharge Current (A) 50 50 50 50 50 50 50
Communication Interface CAN CAN CAN CAN CAN CAN CAN
AC OUTPUT
Rated Output Power (W) 5000 6000 8000 9900 10000 12000 15000
Max Output Power (VA) 5500 6600 8800 9900 11000 13200 16500
Rated Grid Voltage (V) 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE
Rated Grid Frequency (Hz) 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5
Rated AC Current (A) (per phase) 7.6 9.1 12.1 15.0 15.2 18.2 22.7
Max AC Current (A) (per phase) 8.3 10.0 13.3 15.0 16.7 20.0 25.0
Power Factor 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive)
THDi (%) <3 at rated power <3 at rated power <3 at rated power <3 at rated power <3 at rated power <3 at rated power <3 at rated power
AC INPUT
Max AC Input Power (VA) 6000 7200 9600 12000 12000 14400 16000
Nominal AC Grid Voltage (V) 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE
Nominal AC Grid Frequency (Hz) 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5
Max AC Current (A) (per phase) 9.1 10.9 14.5 18.2 18.2 21.8 24.2
EPS OUTPUT
Max EPS Output Power (VA) 5000 6000 8000 10000 10000 12000 15000
Peak Output Power (VA) (60s) 6000 7200 9600 12000 12000 14400 15000
Rated EPS Voltage (V) 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE 400/230; 380/220, 3L/N/PE
Rated EPS Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60
Max EPS Current (A) (per phase) 7.2 8.7 11.6 14.5 14.5 17.4 21.7
Power Factor 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive) 1 (Adjustable from 0.8 capacitive to 0.8 inductive)
Switching Time (ms) <20 <20 <20 <20 <20 <20 <20
THDi (%) <3 (Average linear) <3 (Average linear) <3 (Average linear) <3 (Average linear) <3 (Average linear) <3 (Average linear)
EFFICIENCY
MPPT Efficiency (%) 99.90 99.90 99.90 99.90 99.90 99.90 99.90
Max Efficiency (%) 97.30 97.70 97.70 97.90 97.90 97.90 97.90
European Efficiency (%) 97.20 97.20 97.20 97.20 97.20 97.20 97.20
PROTECTIONS
PV Reverse Polarity Protection YES YES YES YES YES YES YES
Battery Reverse Polarity Protection YES YES YES YES YES YES YES
Anti-islanding Protection YES YES YES YES YES YES YES
Short-circuit Protection YES YES YES YES YES YES YES
Load Current Monitoring YES YES YES YES YES YES YES
Insulation Resistance Monitoring YES YES YES YES YES YES YES
Surge Category III (AC side), II (DC side) III (AC side), II (DC side) III (AC side), II (DC side) III (AC side), II (DC side) III (AC side), II (DC side) III (AC side), II (DC side) III (AC side), II (DC side)
Reverse Polarity Protection YES YES YES YES YES YES YES
Overload Protection / Temperature Protection YES YES YES YES YES YES YES
AC/DC Surge Protection Type II (PV)/Type III (AC) Type II (PV)/Type III (AC) Type II (PV)/Type III (AC) Type II (PV)/Type III (AC) Type II (PV)/Type III (AC) Type II (PV)/Type III (AC) Type II (PV)/Type III (AC)
AFO Protection Optional / slot Optional / slot Optional / slot Optional / slot Optional / slot Optional / slot Optional / slot
DC Switch YES YES YES YES YES YES YES
GENERAL DATA
Dimensions (H × W × D) (mm) 600 × 450 × 226 600 × 450 × 226 600 × 450 × 226 600 × 450 × 226 600 × 450 × 226 600 × 450 × 226 600 × 450 × 226
Packaging Dimensions (H × W × D) (mm) 665 × 545 × 390 665 × 545 × 390 665 × 545 × 390 665 × 545 × 390 665 × 545 × 390 665 × 545 × 390 665 × 545 × 390
Net Weight (kg) 25 25 25 25 25 25 25
Gross Weight (kg) 40 40 40 40 40 40 40
Installation Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted
Operating Temperature Range (°C) -25 – +60 (Derating above 45 °C) -25 – +60 (Derating above 45 °C) -25 – +60 (Derating above 45 °C) -25 – +60 (Derating above 45 °C) -25 – +60 (Derating above 45 °C) -25 – +60 (Derating above 45 °C) -25 – +60 (Derating above 45 °C)
Storage Temperature (°C) -40 – +70 -40 – +70 -40 – +70 -40 – +70 -40 – +70 -40 – +70 -40 – +70
Relative Humidity (storage/operation) (%) 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100
Altitude (m) <4000 (Derating above 2000 m) <4000 (Derating above 2000 m) <4000 (Derating above 2000 m) <4000 (Derating above 2000 m) <4000 (Derating above 2000 m) <4000 (Derating above 2000 m) <4000 (Derating above 2000 m)
Protection Class I I I I I I I
Ingress Protection IP65 (For outdoor use) IP65 (For outdoor use) IP65 (For outdoor use) IP65 (For outdoor use) IP65 (For outdoor use) IP65 (For outdoor use) IP65 (For outdoor use)
Power Consumption (W) 20 ~ 25 20 ~ 25 20 ~ 25 20 ~ 25 20 ~ 25 20 ~ 25 20 ~ 25
Standby Mode YES YES YES YES YES YES YES
Cooling Natural Natural Natural Natural Natural Natural Fan cooling
Noise Level (dB) <40 <40 <40 <40 <40 <55 <55
Inverter Topology Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless
Communication Ethernet, EMS(RS485), meter, WLAN(Wi-Fi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), 5G Ready Ethernet, EMS(RS485), meter, WLAN(Wi-Fi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), 5G Ready Ethernet, EMS(RS485), meter, WLAN(Wi-Fi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), 5G Ready Ethernet, EMS(RS485), meter, WLAN(Wi-Fi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), 5G Ready Ethernet, EMS(RS485), meter, WLAN(Wi-Fi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), 5G Ready Ethernet, EMS(RS485), meter, WLAN(Wi-Fi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), 5G Ready Ethernet, EMS(RS485), meter, WLAN(Wi-Fi+LAN+Bluetooth), 4G(optional), DRM, Ripple Control, USB, BMS(CAN), 5G Ready
Standard Warranty (Years) 10 10 10 10 10 10 10
Buttons 4 × Industrial touch buttons 4 × Industrial touch buttons 4 × Industrial touch buttons 4 × Industrial touch buttons 4 × Industrial touch buttons 4 × Industrial touch buttons 4 × Industrial touch buttons
Buzzer/Alarm 1, Internal (EPS and Ground Monitoring) 1, Internal (EPS and Ground Monitoring) 1, Internal (EPS and Ground Monitoring) 1, Internal (EPS and Ground Monitoring) 1, Internal (EPS and Ground Monitoring) 1, Internal (EPS and Ground Monitoring) 1, Internal (EPS and Ground Monitoring)

[1] For a 1000 V system the maximum PV operating voltage is 950 V.

[2] The inverter start-up voltage is 90 V.

[3] Belgian safety regulations require that a 10000 W output power be 10000 VA. The value for P3-10.0-SH is 11000 VA.