Inverter – GOODWE – GW25K-ETA-G20 – hybrid – HV
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 53,62 kg |
| CN | 85044086 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 53,62 kg |
| CN | 85044086 |
ESA
The ESA by GoodWe is a three-phase, high-voltage “all-in-one” energy storage system that integrates an inverter, LFP (LiFePO4) battery and intelligent energy management. The series covers power from 5–30 kW and storage capacity up to 108 kWh, depending on configuration. The pre-wired, modular design streamlines setup and accelerates commissioning.
Key advantages of the ESA
- Expandable up to 12 battery modules: ability to combine batteries of different capacities and old and new batteries; in a single-column installation the limit is 6 modules.
- Whole-home backup power: design with two ports and transfer to backup power in under 4 ms.
- Optimization for dynamic tariffs: ready to support AI-based energy management systems.
- Grid-tied and off-grid operation: supports parallel operation in both modes.
- System protection: 6-layer safety protection, AI-based AFCI 3.0 arc fault protection and IP66 ingress protection rating.
- Battery heating: heating mode ensures operation down to -20°C; battery modules also have integrated aerosol fire suppression.
Who is this a good choice for?
ESA is intended for households needing energy storage and whole-home backup power and for businesses operating small commercial sites that want scalable capacity and tariff-based energy management optimization. Selection of inverter power and the number and capacity of modules allows tailoring the system configuration to the user’s needs.
| Parameter | GW5K-ETA-G20 | GW6K-ETA-G20 | GW8K-ETA-G20 | GW10K-ETA-G20 | GW12K-ETA-G20 | GW15K-ETA-G20 | GW20K-ETA-G20 | GW25K-ETA-G20 | GW29.999K-ETA-G20 | GW5.1-BAT-D-G20 | GW8.3-BAT-D-G20 | GW6.0-BAT-D-G20 | GW9.0-BAT-D-G20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Battery input data | |||||||||||||
| Battery type | LFP (LiFePO₄) | ||||||||||||
| Nominal voltage (V) | 750 | ||||||||||||
| Voltage range (V) | 700 ~ 950 | ||||||||||||
| Startup voltage (V) | 720 | ||||||||||||
| Number of battery inputs | 1 | ||||||||||||
| DC input data | |||||||||||||
| Maximum PV input power (kW) | 10 | 12 | 16 | 20 | 24 | 30 | 40 | 50 | 60 | ||||
| Maximum PV input voltage (V) | 1000 | ||||||||||||
| AC output data | |||||||||||||
| Inverter AC power (kW) | 5,0 | 6,0 | 8,0 | 10,0 | 12,0 | 15,0 | 20,0 | 25,0 | 30,0 | ||||
| Battery module electrical data | |||||||||||||
| Battery type | LFP (LiFePO₄) | ||||||||||||
| Nominal energy (kWh) | 5,12 | 8,32 | 6,0 | 9,0 | |||||||||
| Usable energy (kWh) | 5,0 | 8,0 | 5,8 | 8,7 | |||||||||
| Operating voltage range in single-phase system (V) | 350 ~ 550 | ||||||||||||
| Operating voltage range in three-phase system (V) | 700 ~ 950 | ||||||||||||
| Maximum system input current (A) | 12,0 | 19,0 | 7,1 | 10,7 | |||||||||
| Maximum system output current (A) | 13,2 | 21,0 | 7,9 | 11,8 | |||||||||
| Maximum system input power (kW) | 5,0 | 8,0 | 3,0 | 4,5 | |||||||||
| Maximum system output power (kW) | 5,0 | 8,0 | 3,0 | 4,5 | |||||||||
| Peak system output power for 10 s (kW) | 7,5 | 12 | 4,5 | 6,75 | |||||||||
| Operating conditions of battery modules | |||||||||||||
| Charging temperature range (°C) | -18 ~ +55 | -20 ~ +55 | |||||||||||
| Discharging temperature range (°C) | -20 ~ +55 | ||||||||||||
| Relative humidity (%) | 4 ~ 100 | ||||||||||||
| Maximum operating altitude (m) | 4000 | ||||||||||||
| Noise emission (dB) | ≤29 | ≤27 | |||||||||||
| Ingress protection rating (IP) | IP66 | ||||||||||||
| Cycle life (cycles) | ≥8000 | ≥10000 | |||||||||||
| Battery module dimensions and weight | |||||||||||||
| Weight (kg) | 57,5 ± 1 | 79 ± 1 | 61 ± 1 | 77 ± 1 | |||||||||
| Dimensions W × H × D (mm) | 800 × 326 × 270 | ||||||||||||
| Battery module equipment and installation | |||||||||||||
| Communication | CAN | CAN & 485 | |||||||||||
| Function configuration | Heating (integrated); aerosol fire suppression (integrated) | ||||||||||||
| Maximum number of modules (pcs) | 12 | ||||||||||||
| Mounting method | Floor stacked / wall mounting | Floor stacked / grounded | |||||||||||
| Battery module certifications | |||||||||||||
| Safety standards and certifications | IEC62619, IEC60730, EN62477, IEC63056, IEC62040, CE, CEC, VDE2510 | IEC62619, IEC60730, EN62477, IEC63056, IEC62040, CE, CEC, Regulation 2023 / 1542, VDE2510-50 | |||||||||||
| Electromagnetic compatibility certifications | CE, RCM | ||||||||||||
| System configuration — 5.12 kWh modules only | |||||||||||||
| Maximum charge and discharge power of the energy storage (kW) | 5 | 6 | 8 | 10 | 12 | 15 | 20 | 25 | 30 | ||||
| Number of modules (pcs) | 1–12 | ||||||||||||
| Minimum nominal capacity (kWh) | 5,12 | ||||||||||||
| Minimum usable capacity (kWh) | 5,00 | ||||||||||||
| Maximum nominal capacity (kWh) | 61,44 | ||||||||||||
| Maximum usable capacity (kWh) | 60,00 | ||||||||||||
| System configuration — 8.32 kWh modules only | |||||||||||||
| Maximum charge and discharge power of the energy storage (kW) | 5 | 6 | 8 | 10 | 12 | 15 | 20 | 25 | 30 | ||||
| Number of modules (pcs) | 1–12 | ||||||||||||
| Minimum nominal capacity (kWh) | 8,32 | ||||||||||||
| Minimum usable capacity (kWh) | 8,00 | ||||||||||||
| Maximum nominal capacity (kWh) | 99,84 | ||||||||||||
| Maximum usable capacity (kWh) | 96,00 | ||||||||||||
| System configuration — mixed 5.12 + 8.32 kWh modules | |||||||||||||
| Maximum charge and discharge power of the energy storage (kW) | 5 | 6 | 8 | 10 | 12 | 15 | 20 | 25 | 30 | ||||
| Number of modules (pcs) | 2–12 | ||||||||||||
| Minimum nominal capacity (kWh) | 13,44 | ||||||||||||
| Minimum usable capacity (kWh) | 13,00 | ||||||||||||
| Maximum nominal capacity (kWh) | 96,64 | ||||||||||||
| Maximum usable capacity (kWh) | 93,00 | ||||||||||||
Usable energy: 100% DOD, 25 ± 2°C, at the beginning of service; for 5.12/8.32 kWh modules measurement at 0.2P, for 6.0/9.0 kWh at 0.4P. Module power is subject to reduction depending on temperature and SOC. In a single-column installation a maximum of 6 modules in parallel. Cycle life based on laboratory tests.