Inverter – GROWATT – MOD 11KTL3-HU – hybrid – LV – AFCI
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 26,72 kg |
| CN | 85044086 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 26,72 kg |
| CN | 85044086 |
MOD 10-15KTL3-HU
MOD 10-15KTL3-HU is a series of three-phase Growatt photovoltaic inverters with a rated AC power of 10–15 kW, depending on the model. The units are prepared for battery integration and offer an integrated backup power function without an additional box. Three MPPT maximum power point tracking units provide flexibility for connecting PV strings.
Key advantages of MOD 10-15KTL3-HU
- Rated AC power 10–15 kW and maximum recommended PV module power 20–30 kW under STC, depending on the model.
- Three MPPT units, each handling one PV string, with a maximum input current of 20 A per unit and an MPPT voltage range of 140–1000 V.
- Battery compatibility: maximum charging power is 15 kW, and maximum discharging power is 10–15 kW, depending on the model.
- Integrated backup power without an additional box, with a rated power of 10–15 kW and a peak apparent power of 12–18 kVA for 10 minutes, depending on the model.
- Maximum efficiency 98.6% and European efficiency 98.1%, natural cooling and a noise level not exceeding 29 dB(A).
- AFCI protection and Type II surge protectors on DC and AC sides, IP66 protection rating and a 10-year warranty.
Who is this a good choice for?
The series is intended for PV system users who need a three-phase inverter with power of 10–15 kW. Battery readiness meets the needs of those planning energy storage, and the integrated backup power function is important for users who want to use this feature without an additional box.
| Parameter | MOD 10KTL3-HU | MOD 11KTL3-HU | MOD 12KTL3-HU | MOD 13KTL3-HU | MOD 15KTL3-HU |
|---|---|---|---|---|---|
| DC Input Data | |||||
| Maximum recommended PV array power (STC) (W) | 20000 | 22000 | 24000 | 26000 | 30000 |
| Max. DC voltage (V) | 1000 | ||||
| Start-up voltage (V) | 160 | ||||
| Nominal DC voltage (V) | 600 | ||||
| MPPT voltage range (V) | 140~1000 | ||||
| Number of MPPT trackers | 3 | ||||
| Number of PV strings per MPPT tracker | 1 | ||||
| Max. input current per MPPT tracker (A) | 20 | ||||
| Max. short-circuit current per MPPT tracker (A) | 25 | ||||
| AC Output Data | |||||
| Nominal AC power (W) | 10000 | 11000 | 12000 | 13000 | 15000 |
| Max. AC apparent power (VA) | 11000 | 12100 | 13200 | 14300 | 16500 |
| Nominal AC voltage (V) | 220/380, 230/400 | ||||
| AC grid frequency and range (Hz) | 50/60 (45~55/55~65) | ||||
| Max. output current (A) | 16,7 | 18,3 | 20 | 21,7 | 25 |
| Adjustable power factor | 0.8 leading...0.8 lagging | ||||
| Total harmonic distortion of current THDi (%) | <3 | ||||
| AC grid connection type | 3W+N+PE/3W+PE | ||||
| DC Battery Data | |||||
| Compatible battery | APX 5,0~30.0P-S2 | ||||
| Operating voltage range (V) | 600~980 | ||||
| Max. operating current (A) | 25 | ||||
| Max. discharge power (kW) | 10 | 11 | 12 | 13 | 15 |
| Max. charging power (kW) | 15 | ||||
| AC Backup Output | |||||
| Nominal AC power (kW) | 10 | 11 | 12 | 13 | 15 |
| Peak apparent power for 10 min (kVA) | 12 | 13,2 | 14,4 | 15,6 | 18 |
| Peak apparent power on one phase (kVA) | 3,33 | 3,67 | 4 | 3,25 | 5 |
| Nominal AC voltage (V) | 220/380, 230/400 | ||||
| Max. output current (A) | 18,2 | 20 | 21,8 | 23,6 | 27,3 |
| AC frequency (Hz) | 50/60 | ||||
| Total harmonic voltage distortion THDv (%) | <3 | ||||
| Efficiency | |||||
| Max. efficiency (%) | 98.60 | ||||
| European efficiency (%) | 98.10 | ||||
| Protections | |||||
| DC reverse polarity protection | Yes | ||||
| DC switch | Yes | ||||
| AC/DC surge protection | Type II | ||||
| Insulation resistance monitoring | Yes | ||||
| AC short-circuit protection | Yes | ||||
| Ground fault monitoring | Yes | ||||
| Grid monitoring | Yes | ||||
| Anti-islanding protection | Yes | ||||
| Residual current monitoring system | Yes | ||||
| PV string fault monitoring | Yes | ||||
| Arc fault protection AFCI | Yes | ||||
| Dimensions and weight | |||||
| Dimensions (W/H/D) (mm) | 468/408/202 | ||||
| Weight (kg) | 20 | ||||
| Operating conditions | |||||
| Operating temperature range (°C) | -25 ... +60 | ||||
| Noise level (dB(A)) | ≤29 | ||||
| Max. operating altitude (m) | 4000 | ||||
| Night power consumption (W) | < 20 | ||||
| Cooling | Natural | ||||
| Protection rating | IP66 | ||||
| Relative humidity (%) | 0~100 | ||||
| General data and communication | |||||
| Topology | Transformerless | ||||
| DC connector | H4/MC4 (Optional) | ||||
| AC connector | Waterproof PG connector + OT terminal | ||||
| Display and operation | OLED+LED/WIFI+APP | ||||
| RS485/CAN/USB interfaces | Yes | ||||
| Monitoring WiFi-X/Wilan-X2/Grohome/Shinemaster-X | Optional | ||||
| Certificates | |||||
| Certificates and standards | CE, N4105, EN50549-1, C10/C11, CEI0-21, G98, G99, G100, AS4777 | ||||
| Warranty | |||||
| Product warranty (years) | 10 | ||||