Inverter – HUAWEI – SUN2000-100KTL-M2
| Manufacturer | |
|---|---|
| Rated power | |
| MPPT | |
| Net depth | |
| Maximum output current [A] | |
| Weight | 96 kg |
| CN | 8504408600 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| MPPT | |
| Net depth | |
| Maximum output current [A] | |
| Weight | 96 kg |
| CN | 8504408600 |
SUN2000-100KTL-M2
The SUN2000-100KTL-M2 by HUAWEI is a transformerless inverter for photovoltaic installations with a rated AC active power of 100 kW. The device offers 10 MPPT trackers and achieves a maximum efficiency of 98.6% at 400 V and 98.8% at 480 V. It supports intelligent I-V curve diagnostics and PV module string fault monitoring.
Key advantages of SUN2000-100KTL-M2
- Output power: rated AC active power of 100 kW and maximum AC active power of 110 kW at cosφ = 1.
- 10 MPPT circuits: a maximum of 2 inputs per MPPT and an MPPT operating voltage range of 200–1000 V.
- Maximum efficiency: 98.6% at 400 V and 98.8% at 480 V.
- PV string protection: AFCI arc fault protection, an intelligent DC string disconnector and type II surge protection devices on the DC and AC sides.
- Diagnostics and communication: intelligent I-V curve diagnostics, RS485 and USB interfaces, and MBUS support requiring an isolation transformer.
- IP66 protection rating: air cooling and an operating temperature range from -25 to 60°C.
Who is this a good choice for?
This is an option for owners of photovoltaic systems requiring an inverter with a rated AC active power of 100 kW. Users who need PV string monitoring have access to I-V curve diagnostics and fault monitoring, while those prioritizing system protection benefit from AFCI functionality, an intelligent DC string disconnector, and Type II surge protection devices.
| Parameter | Value |
|---|---|
| Efficiency | |
| Maximum efficiency (%) | 98.6% @ 400 V, 98.8% @ 480 V |
| European efficiency (%) | 98.4% @ 400 V, 98.6% @ 480 V |
| DC input data | |
| Maximum input voltage (V) | 1100 |
| Maximum current per MPPT (A) | 30 |
| Maximum input current (A) | 20 |
| Maximum short-circuit current per MPPT (A) | 40 |
| Start-up voltage (V) | 200 V |
| MPPT operating voltage range (V) | 200 V ~ 1000 V |
| Rated input voltage (V) | 600 V @ 400 Vac, 720 V @ 480 Vac |
| Number of MPPTs | 10 |
| Maximum number of inputs per MPPT | 2 |
| AC output data | |
| Rated AC active power (W) | 100.000 W |
| Maximum AC apparent power (VA) | 110,000 |
| Maximum AC active power at cosφ=1 (W) | 110,000 |
| Rated output voltage (V) | 400 / 480 |
| Output connection configuration | 3W+(N)+PE |
| Rated AC grid frequency (Hz) | 50 Hz / 60 Hz |
| Rated output current (A) | 144.4 A @ 400 V, 120.3 A @ 480 V |
| Maximum output current (A) | 160.4 @ 400 V, 133.7 @ 480 V |
| Adjustable power factor range | 0.8 leading… 0.8 lagging |
| Maximum total harmonic distortion (%) | < 3 |
| Protection | |
| Input-side disconnecting device | Yes |
| Anti-islanding protection | Yes |
| AC overcurrent protection | Yes |
| DC reverse polarity protection | Yes |
| PV module string fault monitoring | Yes |
| DC surge protector | Type II |
| AC surge protector | Type II |
| DC insulation resistance detection | Yes |
| Residual current monitoring unit (RCMU) | Yes |
| Arc fault protection | Yes |
| Smart DC string disconnector | Yes |
| Communication | |
| Display | LED indicators; WLAN adapter + FusionSolar APP |
| RS485 | Yes |
| USB | Yes |
| Connectivity via Smart Dongle-4G | 4G / 3G / 2G via Smart Dongle – 4G (optional) |
| Monitoring bus (MBUS) | Yes (isolation transformer required) |
| Dimensions and weight | |
| Dimensions (W × H × D) (mm) | 1035 x 700 x 365 |
| Weight with mounting bracket (kg) | 93 |
| Operating conditions | |
| Operating temperature range (°C) | -25°C ~ 60°C |
| Cooling method | Air cooling |
| Maximum working height (m) | 4000 |
| Relative humidity (%) | 0 ~ 100% |
| Protection rating | IP66 |
| General information | |
| DC connector | Amphenol HH4 |
| AC connector | Waterproof connector + OT/DT terminal |
| Structure | Transformerless |
| Nighttime power consumption (W) | < 3.5 W |
| Certificates | |
| Certificates and standards | EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 61727, IEC 60068, IEC 61683 |
| Grid connection standards | VDE-AR-N4105, EN 50549-1, EN 50549-2, RD 661, RD 1699, C10/11 |
Exceeding the maximum DC input voltage may damage the inverter. DC voltage outside the MPPT operating range may cause malfunctions.