Inverter – HUAWEI – SUN 2000-12K-MAP0 – hybrid – HV
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 2 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Yes |
| MPPT voltage range | |
| Weight | 24,82 kg |
| CN | 85044086 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 2 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Yes |
| MPPT voltage range | |
| Weight | 24,82 kg |
| CN | 85044086 |
HUAWEI SUN2000-5/6/8/10/12K-MAPO
The HUAWEI SUN2000-5/6/8/10/12K-MAPO hybrid inverter is an advanced solution for solar energy management and storage, offering high performance, flexibility, and safety. It provides a triple asymmetric output and can work with LUNA2000 batteries, making it an ideal choice for modern photovoltaic installations.
Key features of the HUAWEI SUN2000-5/6/8/10/12K-MAPO:
- Maximum PV power from 9,000 Wp to 22,000 Wp, depending on the model.
- Support for LUNA2000 energy storage (S0/S1) with an operating voltage range of 600–980 V.
- Ability to overload up to 110% of rated power in on-grid mode and up to 200% in off-grid mode.
- Supports triple asymmetric output, providing flexibility in power distribution.
- Advanced safety features, including AFCI, junction temperature detection, and Type II surge protection.
- Low power consumption in night mode (below 5.5 W) and quiet operation thanks to natural convection (below 29 dB).
Who is this a good choice for?
The HUAWEI SUN2000-5/6/8/10/12K-MAPO inverters are designed for residential and commercial users seeking an efficient and reliable energy management system. With support for energy storage and a whole-home backup power function (with SmartGuard), they are ideal for installations where maximizing solar energy use and ensuring power continuity during grid outages are essential.
| Parameter | SUN2000-5K-MAPO | SUN2000-6K-MAPO | SUN2000-8K-MAPO | SUN2000-10K-MAPO | SUN2000-12K-MAPO |
|---|---|---|---|---|---|
| Input (PV) | |||||
| Max. recommended PV power (Wp) | 9,000 Wp | 11,000 Wp | 14,600 Wp | 18,000 Wp | 22,000 Wp |
| Max. input voltage (V) | 1,100 V | 1,100 V | 1,100 V | 1,100 V | 1,100 V |
| Operating voltage range (V) | 160 – 1,000 V | 160 – 1,000 V | 160 – 1,000 V | 160 – 1,000 V | 160 – 1,000 V |
| Start-up voltage (V) | 160 V | 160 V | 160 V | 160 V | 160 V |
| Nominal input voltage (V) | 600 V | 600 V | 600 V | 600 V | 600 V |
| Max. input current per MPPT (A) | 16 A | 16 A | 16 A | 16 A | 16 A |
| Max. short-circuit current (A) | 22 A | 22 A | 22 A | 22 A | 22 A |
| Number of MPPT trackers | 2 | 2 | 2 | 2 | 2 |
| Max. inputs per MPPT | 1 | 1 | 1 | 1 | 1 |
| Input (DC Battery) | |||||
| Compatible battery | LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 | LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 | LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 | LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 | LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 |
| Operating voltage range (V) | 600 – 980 V | 600 – 980 V | 600 – 980 V | 600 – 980 V | 600 – 980 V |
| Max. operating current (A) | 20 A | 20 A | 20 A | 20 A | 20 A |
| Max. charging power (W) | 12,000 W | 12,000 W | 12,000 W | 12,000 W | 12,000 W |
| Max. discharging power (W) | 5,500 W | 6,600 W | 8,800 W | 11,000 W | 12,000 W |
| Output (On Grid) | |||||
| Grid connection | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase |
| Rated output power (W) | 5,000 W | 6,000 W | 8,000 W | 10,000 W | 12,000 W |
| Max. apparent power (VA) | 5,500 VA | 6,600 VA | 8,800 VA | 11,000 VA | 13,200 VA |
| Nominal output voltage (V) | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE |
| Overload capability | 110% | 110% | 110% | 110% | 110% |
| Rated AC grid frequency (Hz) | 50 Hz/60 Hz | 50 Hz/60 Hz | 50 Hz/60 Hz | 50 Hz/60 Hz | 50 Hz/60 Hz |
| Max. output current (A) | 8.3 A | 10.0 A | 13.3 A | 16.7 A | 20.2 A |
| Adjustable power factor | 0.8 leading – 0.8 lagging | 0.8 leading – 0.8 lagging | 0.8 leading – 0.8 lagging | 0.8 leading – 0.8 lagging | 0.8 leading – 0.8 lagging |
| Max. total harmonic distortion (%) | ≤ 3% | ≤ 3% | ≤ 3% | ≤ 3% | ≤ 3% |
| Compatible backup device | SmartGuard-63A-TO (3-phase) | SmartGuard-63A-TO (3-phase) | SmartGuard-63A-TO (3-phase) | SmartGuard-63A-TO (3-phase) | SmartGuard-63A-TO (3-phase) |
| Output (Off Grid) | |||||
| Rated output power (W) | 5,000 W | 6,000 W | 8,000 W | 10,000 W | 12,000 W |
| Nominal output voltage (V) | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE | 220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE |
| 110% overload | Continuous | Continuous | Continuous | Continuous | Continuous |
| 150% overload | 5 min (3-phase) / 5 min (single-phase) | 5 min (3-phase) / 5 min (single-phase) | 5 min (3-phase) / 5 min (single-phase) | 1 min (3-phase) / 5 min (single-phase) | 1 min (3-phase) / 5 min (single-phase) |
| 200% overload | 10 s | 10 s | 10 s | 10 s | 10 s |
| Automatic transfer time (ms) | 20 ms (with SmartGuard-63A-TO) | 20 ms (with SmartGuard-63A-TO) | 20 ms (with SmartGuard-63A-TO) | 20 ms (with SmartGuard-63A-TO) | 20 ms (with SmartGuard-63A-TO) |
| Unbalanced load | Yes, supports 100% three-phase unbalanced load | Yes, supports 100% three-phase unbalanced load | Yes, supports 100% three-phase unbalanced load | Yes, supports 100% three-phase unbalanced load | Yes, supports 100% three-phase unbalanced load |
| Protection features | |||||
| DC-side disconnect device | Yes | Yes | Yes | Yes | Yes |
| Islanding protection | Yes | Yes | Yes | Yes | Yes |
| DC reverse polarity protection | Yes | Yes | Yes | Yes | Yes |
| Insulation detection | Yes | Yes | Yes | Yes | Yes |
| DC surge protection | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 |
| AC surge protection | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 | Yes, compatible with Type II protection per EN/IEC 61643-11 |
| Residual current detection | Yes | Yes | Yes | Yes | Yes |
| AC overcurrent protection | Yes | Yes | Yes | Yes | Yes |
| AC short-circuit protection | Yes | Yes | Yes | Yes | Yes |
| AC overvoltage protection | Yes | Yes | Yes | Yes | Yes |
| Arc fault protection | Yes | Yes | Yes | Yes | Yes |
| Junction temperature detection | Yes (PV and battery junctions) | Yes (PV and battery junctions) | Yes (PV and battery junctions) | Yes (PV and battery junctions) | Yes (PV and battery junctions) |
| Load control | Yes | Yes | Yes | Yes | Yes |
| Battery charging from the grid | Yes | Yes | Yes | Yes | Yes |
| General Specification | |||||
| Max. efficiency (%) | 98.4% | 98.6% | 98.6% | 98.6% | 98.6% |
| European weighted efficiency (%) | 97.5% | 97.7% | 98.0% | 98.1% | 98.2% |
| Operating temperature range (°C) | -25°C to +60°C (-13°F to +140°F) | -25°C to +60°C (-13°F to +140°F) | -25°C to +60°C (-13°F to +140°F) | -25°C to +60°C (-13°F to +140°F) | -25°C to +60°C (-13°F to +140°F) |
| Operating relative humidity (%) | 0% – 100% RH | 0% – 100% RH | 0% – 100% RH | 0% – 100% RH | 0% – 100% RH |
| Max. altitude above sea level (m) | 4,000 m | 4,000 m | 4,000 m | 4,000 m | 4,000 m |
| Cooling | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection |
| Noise level (dB) | ≤ 29 dB | ≤ 29 dB | ≤ 29 dB | ≤ 29 dB | ≤ 29 dB |
| Display | LED indicators; Built-in WLAN + FusionSolar app | LED indicators; Built-in WLAN + FusionSolar app | LED indicators; Built-in WLAN + FusionSolar app | LED indicators; Built-in WLAN + FusionSolar app | LED indicators; Built-in WLAN + FusionSolar app |
| Communication | RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) | RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) | RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) | RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) | RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE (optional); 4G/3G/2G via Smart Dongle-4G (optional); EMMA (optional) |
| Weight (with mounting brackets) (kg) | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg |
| Dimensions (with mounting brackets) (mm) | 490 mm x 460 mm x 130 mm | 490 mm x 460 mm x 130 mm | 490 mm x 460 mm x 130 mm | 490 mm x 460 mm x 130 mm | 490 mm x 460 mm x 130 mm |
| IP rating | IP66 | IP66 | IP66 | IP66 | IP66 |
| Night power consumption (W) | < 5.5 W | < 5.5 W | < 5.5 W | < 5.5 W | < 5.5 W |
| Optimizer compatibility | |||||
| Optimized compatibility | SUN2000-450W-P2, SUN2000-600W-P | SUN2000-450W-P2, SUN2000-600W-P | SUN2000-450W-P2, SUN2000-600W-P | SUN2000-450W-P2, SUN2000-600W-P | SUN2000-450W-P2, SUN2000-600W-P |
| Grid connection standards | |||||
| Standards | EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 | EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 | EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 | EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 | EN/IEC62109-1, EN/IEC62109-2 IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11 |
*1 Max. input voltage is the upper limit of DC voltage. Higher DC voltage may damage the inverter. *2 DC input voltage outside the operating range may cause improper inverter operation.