Three-phase inverter with Synergy technology — Europa SE50K/SE66.6K / SE90K / SE100K / SE120K
SolarEdge three-phase inverters with Synergy technology are advanced solutions designed to maximize the performance and reliability of photovoltaic systems. With a modular design and innovative features such as pre-commissioning and independent operation of the synergy units, they offer easy installation, flexibility, and extended uptime.
Key features of the Three-phase inverter with Synergy technology — Europa SE50K/SE66.6K / SE90K / SE100K / SE120K:
- Easy two-person installation thanks to a lightweight, modular design (2 or 3 synergy units and one synergy management device).
- Independent operation of each synergy unit extends uptime and simplifies maintenance.
- Built-in temperature sensors and arc-fault protection enhance safety.
- Optional rapid shutdown and an integrated DC emergency switch eliminate the need for external isolators.
- Built-in module-level monitoring with Ethernet or cellular communication provides full system visibility.
- Maximum inverter efficiency up to 98.3% and European efficiency up to 98.1%.
Who is this a good choice for?
These inverters are an ideal solution for higher-capacity photovoltaic installations in both commercial and industrial settings, where high performance, reliability, and advanced safety features are priorities. The modular construction and ease of installation also make them an attractive option for installers who value efficient workflows.
| Parameter | SE50K | SE66.6K | SE90K | SE100K | SE120K |
| OUTPUT | |||||
| Rated AC output active power (W) | 50000 | 66600 | 90000 | 100000 | 120000 |
| Maximum AC apparent output power (VA) | 50000 | 66600 | 90000 | 100000 | 120000 |
| AC output voltage — phase-to-phase/phase-to-neutral (nominal) (Vac) | 380/220; 400/230 | 380/220; 400/230 | 380/220; 400/230 | 380/220; 400/230 | 480/277 |
| AC output voltage — range phase-to-phase/phase-to-neutral (Vac) | 304 – 437/176 – 253; 320 – 460/184 – 264.5 | 304 – 437/176 – 253; 320 – 460/184 – 264.5 | 304 – 437/176 – 253; 320 – 460/184 – 264.5 | 304 – 437/176 – 253; 320 – 460/184 – 264.5 | 432-529/249-305 |
| AC frequency (Hz) | 50/60 ± 5% | 50/60 ± 5% | 50/60 ± 5% | 50/60 ± 5% | 50/60 ± 5% |
| Maximum continuous output current (per phase) (Aac) | 72.5 | 96.5 | 130.5 | 145 | 145 |
| Total harmonic distortion (THD) (%) | ≤ 3 | ≤ 3 | ≤ 3 | ≤ 3 | ≤ 3 |
| Power factor range | ± 0.8 to 1 | ± 0.8 to 1 | ± 0.8 to 1 | ± 0.8 to 1 | ± 0.8 to 1 |
| INPUT | |||||
| Maximum DC power (STC module) inverter / synergy unit (W) | 75000/37500 | 100000 / 50000 | 135000 / 45000 | 150000 / 50000 | 180000/60000 |
| Maximum DC input voltage DC+ to DC- (VDC) | 750 | 750 | 750 | 750 | 850 |
| Nominal DC input voltage DC+ to DC- (VDC) | 2 x 36.25 | 2 x 48.25 | 3 x 43.5 | 3 x 48.25 | 3 x 48.25 |
| Maximum input current (A) | 1000 | 1000 | 1000 | 1000 | 1000 |
| Maximum inverter efficiency (%) | 98.3 | 98.3 | 98.3 | 98.3 | 98.1 |
| European (weighted) efficiency (%) | 98 | 98 | 98 | 98 | 98 |
| Nighttime power consumption (W) | < 8 | < 8 | < 12 | < 12 | < 12 |
| OTHER FEATURES | |||||
| Supported communication interfaces(5) | 2 x RS485, Ethernet, Wi‑Fi (optional), cellular network (optional) | ||||
| Protection against disturbances caused by electrical arcs | Built-in, user-configurable (per UL1699B) | ||||
| Rapid shutdown | Optional (automatic after disconnection from AC grid) | ||||
| PID controller | Night-time control, built-in | ||||
| RS485 surge protection (ports 1+2) | Type II, field-replaceable, integrated | ||||
| DC surge protection | Type II, field-replaceable, integrated | ||||
| AC surge protection | Type II, field-replaceable, optional | ||||
| DC fuses (single-pole) | 25 A, optional | ||||
| DC isolator | Optional | ||||
| INSTALLATION PARAMETERS | |||||
| Number of synergy units per inverter | 2 | 2 | 3 | 3 | 3 |
| AC cable cross-section and outer diameter: line/PE (aluminum or copper) (mm) | Cross-section up to 120/70 mm²; outer diameter 30-50/12-20 mm | Cross-section up to 120/70 mm²; outer diameter 30-50/12-20 mm | Cross-section up to 50 mm², aluminum or copper, cable outer diameter 12-20 mm | Cross-section up to 50 mm², aluminum or copper, cable outer diameter 12-20 mm | Cross-section up to 50 mm², aluminum or copper, cable outer diameter 12-20 mm |
| DC input: inverter / synergy unit (7)(8) | 8/4 pairs MC4 | 12/4 pairs MC4 | Gland, 3 pairs/1 pair, cross-section up to 50 mm² aluminum or copper, cable outer diameter 12-20 mm | Gland, 3 pairs/1 pair, cross-section up to 50 mm² aluminum or copper, cable outer diameter 12-20 mm | Gland, 3 pairs/1 pair, cross-section up to 50 mm² aluminum or copper, cable outer diameter 12-20 mm |
| Dimensions (H x W x D) (mm) | Synergy unit: 558 x 328 x 273; Synergy management device: 360 x 560 x 295 | ||||
| Weight (kg) | Synergy unit: 32; Synergy management device: 18 | ||||
| Operating temperature range (°C) | from -40 to +60(9) | ||||
| Cooling | Fan (replaceable) | ||||
| Noise emission (dBA) | < 67 | ||||
| Protection rating | IP65 outdoors and indoors | ||||
| Mounting | Mounting bracket included | ||||
| COMPLIANCE STANDARDS | |||||
| Safety | IEC-62109-1, IEC-62109-2, AS3100 | ||||
| Grid connection standards (6) | EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Erzeuger Typ A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 | ||||
| EMC | IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12 | ||||
| RoHS | Yes | ||||
Note: Specifications are subject to change without notice.