Inverter – SOLAREDGE – SE2200H – RW000BEN4 – single-phase
| Manufacturer | |
|---|---|
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| CN | 85044085 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| CN | 85044085 |
SolarEdge single-phase inverter with HD-Wave technology (SE2200H-SE6000H)
SolarEdge single-phase inverter with HD-Wave technology (models SE2200H to SE6000H) is an advanced device specifically designed to work with power optimizers. Thanks to its innovative power conversion technology, it provides record efficiency reaching up to 99% and a stable voltage for longer strings. It features an exceptionally small and lightweight design that facilitates installation both indoors and outdoors.
Key features of the single-phase inverter with HD-Wave technology:
- Record efficiency: Maximum inverter efficiency up to 99% (weighted European efficiency in the range 98,3% – 98,8%) ensuring maximum energy harvest.
- Compact design: Extremely small, lightweight (weight from 7,8 kg to 10,6 kg depending on the model) and easy to install.
- Integrated monitoring: Advanced module-level monitoring system for full control of the installation’s performance.
- Safety and reliability: Built-in arc fault protection (compliant with UL1699B) and a high IP65 protection rating for outdoor installation.
- Flexibility and communication: Supports interfaces such as RS485, Ethernet and optionally ZigBee, WLAN and cellular.
- Energy management: Full compatibility with the StorEdge interface for advanced smart energy management and storage.
Who is this a good choice for?
This inverter is an excellent choice for homeowners and investors seeking highly efficient, reliable and safe photovoltaic micro-installations. It is ideal for residential buildings where optimizing energy yield from each panel, installation flexibility and the possibility to expand the system with smart energy management and storage in the future are key considerations.
| Parameter | SE2200H | SE3000H | SE3500H | SE3680H | SE4000H | SE5000H | SE6000H |
|---|---|---|---|---|---|---|---|
| OUTPUT | |||||||
| Rated AC power (VA) | 2200 | 3000 | 3500 | 3680 | 4000 | 5000(1) | 6000 |
| Maximum AC power (VA) | 2200 | 3000 | 3500 | 3680 | 4000 | 5000(1) | 6000 |
| AC output voltage (nominal) (V) | 220 / 230 | 220 / 230 | 220 / 230 | 220 / 230 | 220 / 230 | 220 / 230 | 220 / 230 |
| AC output voltage range (V) | 184–264,5 | 184–264,5 | 184–264,5 | 184–264,5 | 184–264,5 | 184–264,5 | 184–264,5 |
| AC frequency (nominal) (Hz) | 50 / 60 ± 5 | 50 / 60 ± 5 | 50 / 60 ± 5 | 50 / 60 ± 5 | 50 / 60 ± 5 | 50 / 60 ± 5 | 50 / 60 ± 5 |
| Maximum continuous output current (A) | 10 | 14 | 16 | 16 | 18,5 | 23 | 27,5 |
| Grid monitoring, anti-islanding protection, country-configurable thresholds | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| INPUT | |||||||
| Maximum DC power (W) | 3400 | 4650 | 5425 | 5700 | 6200 | 7750(2) | 9300 |
| Transformerless, ungrounded | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Maximum input voltage (V) | 480 | 480 | 480 | 480 | 480 | 480 | 480 |
| Rated DC input voltage (V) | 380 | 380 | 380 | 380 | 380 | 380 | 380 |
| Maximum input current (A) | 6,5 | 9 | 10 | 10,5 | 11,5 | 13,5 | 16,5 |
| Reverse polarity protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Ground fault detection | Sensitivity 600 kΩ | Sensitivity 600 kΩ | Sensitivity 600 kΩ | Sensitivity 600 kΩ | Sensitivity 600 kΩ | Sensitivity 600 kΩ | Sensitivity 600 kΩ |
| Maximum inverter efficiency (%) | 99,2 | 99,2 | 99,2 | 99,2 | 99,2 | 99,0 | 99,0 |
| Weighted European efficiency (%) | 98,3 | 98,8 | 98,8 | 98,8 | 98,8 | 98,8 | 98,8 |
| Nighttime power consumption (W) | < 2,5 | < 2,5 | < 2,5 | < 2,5 | < 2,5 | < 2,5 | < 2,5 |
| OTHER FEATURES | |||||||
| Supported communication interfaces | RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) | RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) | RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) | RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) | RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) | RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) | RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) |
| Smart energy management | Power export limiting, smart energy, StorEdge solutions | Power export limiting, smart energy, StorEdge solutions | Power export limiting, smart energy, StorEdge solutions | Power export limiting, smart energy, StorEdge solutions | Power export limiting, smart energy, StorEdge solutions | Power export limiting, smart energy, StorEdge solutions | Power export limiting, smart energy, StorEdge solutions |
| Arc fault protection | Integrated, user-configurable (compliant with UL1699B) | Integrated, user-configurable (compliant with UL1699B) | Integrated, user-configurable (compliant with UL1699B) | Integrated, user-configurable (compliant with UL1699B) | Integrated, user-configurable (compliant with UL1699B) | Integrated, user-configurable (compliant with UL1699B) | Integrated, user-configurable (compliant with UL1699B) |
| STANDARDS MET | |||||||
| Safety | IEC-62109-1/2, AS-3100 | IEC-62109-1/2, AS-3100 | IEC-62109-1/2, AS-3100 | IEC-62109-1/2, AS-3100 | IEC-62109-1/2, AS-3100 | IEC-62109-1/2, AS-3100 | IEC-62109-1/2, AS-3100 |
| Grid connection | AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 | AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 | AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 | AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 | AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 | AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 | AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 |
| Electromagnetic compatibility (EMC) | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B |
| MECHANICAL SPECIFICATION | |||||||
| AC output cable diameter (mm) | 9-16 | 9-16 | 9-16 | 9-16 | 9-16 | 9-16 | 9-16 |
| AC conductor cross-section (mm²) | 1-13 | 1-13 | 1-13 | 1-13 | 1-13 | 1-13 | 1-13 |
| DC input | 1 pair MC4 | 1 pair MC4 | 1 pair MC4 | 1 pair MC4 | 1 pair MC4 | 2 pairs MC4 | 2 pairs MC4 |
| Dimensions (H × W × D) (mm) | 280 × 370 × 142 | 280 × 370 × 142 | 280 × 370 × 142 | 280 × 370 × 142 | 280 × 370 × 142 | 280 × 370 × 142 | 280 × 370 × 142 |
| Noise level (dBA) | < 25 | < 25 | < 25 | < 25 | < 25 | < 25 | < 25 |
| Weight (kg) | 7,8 | 7,8 | 7,8 | 7,8 | 7,8 | 10,6 | 10,6 |
| Cooling type | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection |
| Operating temperature range (°C) | -20 to +60(3) (optionally -40) | -20 to +60(3) (optionally -40) | -20 to +60(3) (optionally -40) | -20 to +60(3) (optionally -40) | -20 to +60(3) (optionally -40) | -20 to +60(3) (optionally -40) | -20 to +60(3) (optionally -40) |
| Protection rating | IP65 for outdoor or indoor installations | IP65 for outdoor or indoor installations | IP65 for outdoor or indoor installations | IP65 for outdoor or indoor installations | IP65 for outdoor or indoor installations | IP65 for outdoor or indoor installations | IP65 for outdoor or indoor installations |
(1) 4600 VA in Germany.
(2) 7130 VA in Germany.
(3) For information on power derating due to temperature, refer to the manufacturer’s technical documentation.