Product details

Manufacturer

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

CAN

CAN 2.0

RS485

SPD Type I

SPD Type II

SPD Type III

SPD Type I+II

SPD – Free slot

AFCI

CN 85044085

SolarEdge single-phase inverter with HD-Wave technology (SE2200H-SE6000H)

SolarEdge single-phase inverter with HD-Wave technology (models SE2200H to SE6000H) is an advanced device specifically designed to work with power optimizers. Thanks to its innovative power conversion technology, it provides record efficiency reaching up to 99% and a stable voltage for longer strings. It features an exceptionally small and lightweight design that facilitates installation both indoors and outdoors.

Key features of the single-phase inverter with HD-Wave technology:

  • Record efficiency: Maximum inverter efficiency up to 99% (weighted European efficiency in the range 98,3% – 98,8%) ensuring maximum energy harvest.
  • Compact design: Extremely small, lightweight (weight from 7,8 kg to 10,6 kg depending on the model) and easy to install.
  • Integrated monitoring: Advanced module-level monitoring system for full control of the installation’s performance.
  • Safety and reliability: Built-in arc fault protection (compliant with UL1699B) and a high IP65 protection rating for outdoor installation.
  • Flexibility and communication: Supports interfaces such as RS485, Ethernet and optionally ZigBee, WLAN and cellular.
  • Energy management: Full compatibility with the StorEdge interface for advanced smart energy management and storage.

Who is this a good choice for?

This inverter is an excellent choice for homeowners and investors seeking highly efficient, reliable and safe photovoltaic micro-installations. It is ideal for residential buildings where optimizing energy yield from each panel, installation flexibility and the possibility to expand the system with smart energy management and storage in the future are key considerations.

Parameter SE2200H SE3000H SE3500H SE3680H SE4000H SE5000H SE6000H
OUTPUT
Rated AC power (VA) 2200 3000 3500 3680 4000 5000(1) 6000
Maximum AC power (VA) 2200 3000 3500 3680 4000 5000(1) 6000
AC output voltage (nominal) (V) 220 / 230 220 / 230 220 / 230 220 / 230 220 / 230 220 / 230 220 / 230
AC output voltage range (V) 184–264,5 184–264,5 184–264,5 184–264,5 184–264,5 184–264,5 184–264,5
AC frequency (nominal) (Hz) 50 / 60 ± 5 50 / 60 ± 5 50 / 60 ± 5 50 / 60 ± 5 50 / 60 ± 5 50 / 60 ± 5 50 / 60 ± 5
Maximum continuous output current (A) 10 14 16 16 18,5 23 27,5
Grid monitoring, anti-islanding protection, country-configurable thresholds Yes Yes Yes Yes Yes Yes Yes
INPUT
Maximum DC power (W) 3400 4650 5425 5700 6200 7750(2) 9300
Transformerless, ungrounded Yes Yes Yes Yes Yes Yes Yes
Maximum input voltage (V) 480 480 480 480 480 480 480
Rated DC input voltage (V) 380 380 380 380 380 380 380
Maximum input current (A) 6,5 9 10 10,5 11,5 13,5 16,5
Reverse polarity protection Yes Yes Yes Yes Yes Yes Yes
Ground fault detection Sensitivity 600 kΩ Sensitivity 600 kΩ Sensitivity 600 kΩ Sensitivity 600 kΩ Sensitivity 600 kΩ Sensitivity 600 kΩ Sensitivity 600 kΩ
Maximum inverter efficiency (%) 99,2 99,2 99,2 99,2 99,2 99,0 99,0
Weighted European efficiency (%) 98,3 98,8 98,8 98,8 98,8 98,8 98,8
Nighttime power consumption (W) < 2,5 < 2,5 < 2,5 < 2,5 < 2,5 < 2,5 < 2,5
OTHER FEATURES
Supported communication interfaces RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional) RS485, Ethernet, ZigBee (optional), WLAN (optional), cellular (optional)
Smart energy management Power export limiting, smart energy, StorEdge solutions Power export limiting, smart energy, StorEdge solutions Power export limiting, smart energy, StorEdge solutions Power export limiting, smart energy, StorEdge solutions Power export limiting, smart energy, StorEdge solutions Power export limiting, smart energy, StorEdge solutions Power export limiting, smart energy, StorEdge solutions
Arc fault protection Integrated, user-configurable (compliant with UL1699B) Integrated, user-configurable (compliant with UL1699B) Integrated, user-configurable (compliant with UL1699B) Integrated, user-configurable (compliant with UL1699B) Integrated, user-configurable (compliant with UL1699B) Integrated, user-configurable (compliant with UL1699B) Integrated, user-configurable (compliant with UL1699B)
STANDARDS MET
Safety IEC-62109-1/2, AS-3100 IEC-62109-1/2, AS-3100 IEC-62109-1/2, AS-3100 IEC-62109-1/2, AS-3100 IEC-62109-1/2, AS-3100 IEC-62109-1/2, AS-3100 IEC-62109-1/2, AS-3100
Grid connection AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1 AS-4777, VDE-AR-N-4105, VDE 0126-1-1, UTE C15-712, G83/2, G59/3, CEI-021, EN 50438, IEC61727, IEC62116, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1
Electromagnetic compatibility (EMC) IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15, class B
MECHANICAL SPECIFICATION
AC output cable diameter (mm) 9-16 9-16 9-16 9-16 9-16 9-16 9-16
AC conductor cross-section (mm²) 1-13 1-13 1-13 1-13 1-13 1-13 1-13
DC input 1 pair MC4 1 pair MC4 1 pair MC4 1 pair MC4 1 pair MC4 2 pairs MC4 2 pairs MC4
Dimensions (H × W × D) (mm) 280 × 370 × 142 280 × 370 × 142 280 × 370 × 142 280 × 370 × 142 280 × 370 × 142 280 × 370 × 142 280 × 370 × 142
Noise level (dBA) < 25 < 25 < 25 < 25 < 25 < 25 < 25
Weight (kg) 7,8 7,8 7,8 7,8 7,8 10,6 10,6
Cooling type Natural convection Natural convection Natural convection Natural convection Natural convection Natural convection Natural convection
Operating temperature range (°C) -20 to +60(3) (optionally -40) -20 to +60(3) (optionally -40) -20 to +60(3) (optionally -40) -20 to +60(3) (optionally -40) -20 to +60(3) (optionally -40) -20 to +60(3) (optionally -40) -20 to +60(3) (optionally -40)
Protection rating IP65 for outdoor or indoor installations IP65 for outdoor or indoor installations IP65 for outdoor or indoor installations IP65 for outdoor or indoor installations IP65 for outdoor or indoor installations IP65 for outdoor or indoor installations IP65 for outdoor or indoor installations

(1) 4600 VA in Germany.
(2) 7130 VA in Germany.
(3) For information on power derating due to temperature, refer to the manufacturer’s technical documentation.

Official distribution