Inverter – SOLAX – X3-AELIO-50K
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 111,6 kg |
| CN | 85044086 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 111,6 kg |
| CN | 85044086 |
Inverter SOLAX X3 AELIO 50K
The Solax X3 AELIO inverter is an advanced solution that delivers safety, robustness, and intelligence. With dual SPD protection (AC & DC Type II), off-grid capability, and advanced diagnostic features, it’s a reliable choice for energy management.
Key features of the Solax X3 AELIO:
- IP66 protection rating and built-in AC&DC SPD Type II safeguards for reliable safety.
- Robust backup capability with a transfer time < 10 ms and EPS output power up to 150%.
- Smart features including AI-ready functions, energy production forecasting, and microgrid-ready operation.
- Cost-effective options, including up to 200% PV input power and 40 A input current per MPPT.
- Supports various lithium‑ion battery types with a maximum charge/discharge current of 160 A.
- Wide operating temperature range from -35 to 60°C and advanced communication interfaces: RS485, CAN, USB.
Who is this a good choice for?
This solution is ideal for commercial and industrial installations seeking highly efficient, safe, and flexible energy storage systems. Off-grid capability, support for multiple scenarios, intelligent energy management, and robust diagnostic functions make it an excellent choice for ensuring power continuity and optimizing energy costs.
| Parameter | X3-AELIO-49.9K | X3-AELIO-50K | X3-AELIO-60K | X3-AELIO-61K |
|---|---|---|---|---|
| PV input | ||||
| Max PV input power (kW) | 100 | 100 | 120 | 121 |
| Max PV input voltage (V) | 1000 | 1000 | 1000 | 1000 |
| Start-up voltage (V) | 200 | 200 | 200 | 200 |
| Nominal PV input voltage (V) | 650 | 650 | 650 | 650 |
| MPPT voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 |
| Number of MPP trackers / strings per MPP tracker | 5 (2 per MPPT) | 5 (2 per MPPT) | 6 (2 per MPPT) | 6 (2 per MPPT) |
| Max input current per MPPT (A) | 40 | 40 | 40 | 40 |
| Max input short-circuit current per MPPT (A) | 50 | 50 | 50 | 50 |
| AC output | ||||
| Rated AC output power (kW) | 49.9 | 50 | 60 | 61 |
| Rated AC output current (A) | 72.3 | 72.5 | 87.0 | 88.4 |
| Max apparent power at AC output (kVA) | 49.9 | 55 | 66 | 66 |
| Max AC output current (A) | 83.2 | 83.3 | 100.0 | 101.7 |
| Rated AC voltage (V) | 3P4W, 400/230, 380/220 | |||
| Rated AC grid frequency (Hz) | 50/60 | |||
| Adjustable power factor range (rated power) | 1 (0.8 leading ~ 0.8 lagging) | |||
| THDi (rated power) (%) | < 3 | |||
| Battery data | ||||
| Battery type | Lithium-ion | |||
| Battery voltage range (V) | 180 – 820 | |||
| Max charge/discharge current (A) | 160 (80×2) | |||
| EPS output (with battery) | ||||
| Peak AC apparent power (kVA) | 49.9 | 55 | 66 | 66 |
| Nominal voltage (V); Frequency (Hz) | 3P4W, 400/230V, 380/220V; 50/60Hz | |||
| Max continuous output current (A) | 72.0 | 83.6 | 100.3 | 100.3 |
| Transfer time (ms) | < 10 | |||
| General | ||||
| Max efficiency (%) | 98 | |||
| European weighted efficiency (%) | 97.2 | |||
| Ingress protection | IP66 | |||
| Operating ambient temperature range (°C) | -35 ~ 60 | |||
| Max operating altitude (m) | < 3000 | |||
| Relative humidity (%) | 0~100 | |||
| Typical noise emission (dB) | < 70 | |||
| Dimensions (W x H x D) (mm) | 820 x 670 x 257 | |||
| Net weight (kg) | 100.3 | |||
| Cooling concept | Smart air cooling | |||
| Communication interfaces | RS485, CAN(BMS), CAN, USB, DI, DO, DRM | |||
| Display | LCD (optional) | |||
| Power consumption | ||||
| Standby (night) power consumption (W) | < 10 | |||
| Protection | ||||
| Over/under voltage protection | Yes | |||
| DC isolation protection | Yes | |||
| DC reverse polarity protection | Yes | |||
| Grid monitoring | Yes | |||
| DC injection monitoring | Yes | |||
| Reverse current monitoring | Yes | |||
| Residual current detection | Yes | |||
| Anti-islanding protection | Yes | |||
| Overheat protection | Yes | |||
| SPD (DC/AC) | Type II/Type II | |||
| Arc-fault circuit interrupter (AFCI) | OPT | |||
| Certification | ||||
| Safety | EN/IEC 62109-1/-2 | |||
| EMC | EN 61000-6-1/2/3/4, EN 61000-3-11/12, EN 55011, IEC 62920 | |||
| Standards | VDE4105, G99, AS4777, EN50549, CEI 0-21, IEC61727, PEA/MEA, NRS-097-2-1, RD1699, TOR | |||