Inverter SOLAX X3-HYB-10.0-G4 Pro WiFi + LAN
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Sprawność europejska | |
| Weight | 40,25 kg |
| CN | 85044086 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Sprawność europejska | |
| Weight | 40,25 kg |
| CN | 85044086 |
Three-phase Hybrid Inverter SolaX Power X3-HYB-G4 PRO
The three-phase SolaX Power X3-HYB-G4 PRO hybrid inverter is an advanced solution for residential installations, offering intelligent energy management and high performance. Available in a wide power range from 4 kW to 15 kW, it supports V2H technology, smart scheduling, and integration with a wireless meter. With dual battery ports, a wide MPPT range and support for 200% PV oversizing, it is a flexible and reliable device for maximizing self-consumption.
Key features of the SolaX Power X3-HYB-G4 PRO Hybrid Inverter:
- Intelligent energy management: V2H compatibility for smart home energy integration, Smart Schedule, Smart Scene, 24/7 TOU and integration with VPPs (OpenADR, IEEE2030.5, FCAS, API).
- High PV performance and flexibility: 20 A DC input per MPPT with 3 trackers, support for 200% PV oversizing, AC output up to 110% and a very wide MPPT range (110–950 V).
- Proven reliability and safety: Up to 200% EPS output for 10 seconds, UPS-level switch-over time below 10 ms, optional rapid shutdown function, Type II SPD protection on AC and DC sides and optional AFCI protection.
- Flexible adaptation options: Dual battery ports and a 2-in-1 expansion function, additional ports to simplify wiring, and a functional, stylish cable cover.
- Versatile operating modes: Support for microgrid and generator modes for a variety of applications.
- Performance curve: High efficiency maintained across a wide load range, as demonstrated by the performance curve for the 15 kW model.
Who is this a good choice for?
The SolaX Power X3-HYB-G4 PRO inverter is an excellent choice for owners of single-family homes looking for an advanced, efficient and reliable hybrid system. Its intelligent energy management features, high flexibility in PV and battery configuration, and extensive safety and adaptation options make it ideal for maximizing self-consumption, providing backup power and integrating with a smart home. The wide power range allows the system to be tailored to individual energy needs.
| Parameter | X3-HYB-4.0-P | X3-HYB-5.0-P | X3-HYB-6.0-P | X3-HYB-8.0-P | X3-HYB-10.0-P | X3-HYB-12.0-P | X3-HYB-15.0-P |
|---|---|---|---|---|---|---|---|
| PV INPUT | |||||||
| Max. recommended PV array power (kWp) | 8 | 10 | 12 | 16 | 20 | 24 | 30 |
| Max. PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
| Rated PV input voltage (V) | 650 | 650 | 650 | 650 | 650 | 650 | 650 |
| Operating voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| MPPT voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| Start-up voltage (V) | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
| Number of MPP trackers / strings per MPP tracker | 2 (1 / 1) | 2 (1 / 1) | 2 (1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) |
| Max. input current per MPPT (MPPT1/2/3) (A) | 20 / 20 | 20 / 20 | 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 |
| Max. short-circuit input current per MPPT (MPPT1/2/3) (A) | 25 / 25 | 25 / 25 | 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 |
| AC INPUT AND OUTPUT (GRID-TIED) | |||||||
| Rated output power (W) | 4000 | 5000 (AS 4777 4999 W) | 6000 | 8000 | 10000 (AS 4777 9999 W) | 12000 | 15000 (AS 4777 14999 W) |
| Rated output current (A) | 5.8 | 7.2 | 8.7 | 11.6 | 14.5 | 17.5 | 21.8 |
| Max. apparent output power (VA) | 4400 | 5500 (AS 4777 4999 VA) | 6600 | 8800 | 11000 (AS 4777 9999 VA) | 13200 | 16500 (AS 4777 14999 VA) |
| Max. continuous output current (A) | 6.7 | 6.7 | 8.4 | 10.0 | 13.4 | 20.0 | 25.0 |
| Nominal AC voltage | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V |
| Max. apparent AC input power (kVA) | 8.4 | 10.5 | 12.6 | 16.8 | 21.0 | 21.0 | 21.0 |
| Max. AC input current (A) | 12.2 | 15.2 | 18.2 | 24.3 | 30.4 | 30.4 | 30.4 |
| Nominal AC frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
| AC frequency range (Hz) | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 |
| Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
| THDi (Rated Power) (%) | <3 | <3 | <3 | <3 | <3 | <3 | <3 |
| BATTERY | |||||||
| Battery type | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium |
| Battery voltage range (V) | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 |
| Max. charge/discharge current (A) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) |
| EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||||
| EPS nominal output voltage, frequency | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz |
| Rated EPS output power (kVA) | 4 | 5 | 6 | 8 | 10 | 12 | 15 |
| Peak EPS output power | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
| Transfer time (ms) | < 10 | < 10 | < 10 | < 10 | < 10 | < 10 | |
| EFFICIENCY | |||||||
| Max. efficiency (%) | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 |
| European efficiency (%) | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 |
| ENVIRONMENTAL LIMITS | |||||||
| Ingress protection | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating ambient temperature range (°C) | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 |
| Max. operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 |
| Relative humidity | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) |
| Overvoltage category | AC supply: III, Battery: II, PV: II | AC supply: III, Battery: II, PV: II | AC supply: III, Battery: II, PV: II | AC supply: III, Battery: II, PV: II | AC supply: III, Battery: II, PV: II | AC supply: III, Battery: II, PV: II | AC supply: III, Battery: II, PV: II |
| GENERAL | |||||||
| Dimensions (W x H x D) (mm) | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 |
| Net weight (kg) | 38 | 38 | 38 | 38 | 38 | 38 | 38 |
| Cooling method | Natural cooling | Natural cooling | Natural cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
| Communication interfaces | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) |
| Power consumption (night) (W) | < 40 W in standby, < 5 W in idle | < 40 W in standby, < 5 W in idle | < 40 W in standby, < 5 W in idle | < 40 W in standby, < 5 W in idle | < 40 W in standby, < 5 W in idle | < 40 W in standby, < 5 W in idle | < 40 W in standby, < 5 W in idle |
| Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
| Certificates and approvals | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 |
| Auxiliary AC power (APS) | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in |
| PROTECTION | |||||||
| Protections | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection |
| Active anti-islanding method | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift |
| Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
| Arc-fault circuit interrupter (AFCI) | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
Notes:
① The maximum input voltage is the upper limit of the DC voltage. Any higher DC input voltage may damage the inverter.
② Input voltage exceeding the MPPT voltage range may trigger the inverter’s protection.
③ The AC frequency range may vary depending on country codes.
④ If each of the two battery ports is connected to a separate battery, the current is 25 A per port. If one port is connected to a single battery, it’s 30 A. If both ports are connected to a single battery using a 2-in-1 splitter cable (sold separately), the current is 50 A.
⑤ Values are derated at +45°C.